GB/T 24947-2010Requirement for water quality of marine auxiliary boiler (English PDF)
船用辅锅炉水质要求
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 24947-2010 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
August 9, 2010
Implementation date
December 1, 2010
Scope
GB/T 24947-2010 is the English-translated version of 船用辅锅炉水质要求.
GB/T 24947-2010 sets the water quality requirements for a marine auxiliary boiler in operation, which it shortens to the "boiler".
Clause 1 limits it to boilers whose design pressure is less than 2.5 MPa and whose medium is water and saturated steam, namely fuel boilers, gas boilers and fuel gas combination boilers, and to hot water boilers whose medium outlet temperature does not exceed 120 °C. The body as far as the draft goes runs Scope, Normative references, Terms and Definitions and Requirements, and clause 2 cites GB/T 1576.
Clause 3 defines two kinds of water: the water delivered to the boiler inlet by a feed pump from feed water and condensate, and the concentrated water circulating inside the boiler, generally the water in the drum.
Clause 4 states that feedwater for steam boilers should generally be treated chemically and that the water quality must meet Table 1, which fixes limits for both waters in three rated pressure bands up to 2.5 MPa, covering total hardness, total alkalinity, salinity as Cl-, pH at 25 °C, suspension, DO, dissolved solids, oil content, iron content, sulfite and phosphate.
The draft ends with Table 1. It was proposed by China State Shipbuilding Corporation and administered by the National Marine Machinery Standardization Technical Committee. It was issued on 2010-08-09 and has applied since 2010-12-01.
Found what you need?
Document preview — GB/T 24947-2010
National Standard of the People's Republic of China
- ICS
- 47.020.20
- Classification
- U 41
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Requirements
Foreword
The standard proposed by China State Shipbuilding Corporation.
1 Scope
This standard specifies the marine auxiliary boiler (hereinafter referred to as "boiler") water quality requirements at runtime.
This standard applies to the design pressure is less than 2.5MPa, medium is water and saturated steam boiler fuel, gas boiler, fuel gas group Fit the boiler, as well as medium outlet temperature does not exceed 120 °C hot water boiler.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 1576 industrial boiler water quality
3 Terms and Definitions
The following terms and definitions apply to this standard.
3.1 Feedwater
By a feed pump from the feed water, condensate boiler inlet supply boilers and the like.
3.2 Boiler water
Circulating boiler, means the concentrated water inside the boiler. Generally refers to the water within the drum.
4 Requirements
4.1
Steam boiler feedwater should generally use the pot for chemical water treatment. The water quality should meet the requirements in Table 1.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download GB/T 24947-2010
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 1576-2018 — Water quality for industrial boilers
GB/T 15761-1995 — Design and construction rulesfor nuclear island systems of 2×600MW PWR nuclear power plants
GB/T 15762-2020 — Autoclaved aerated concrete slabs
Secure payment via Stripe
Payments accepted
GB/T 24947-2010