Scope

GB/T 24818.5-2009 is the English-translated version of 起重机 通道及安全防护设施 第5部分:桥式和门式起重机.

GB/T 24818.5-2009 — This section GB/T 24818 requirements by GB/T 6974.1 definition of bridge and gantry crane access and security facilities in the Special requirements, and gives the bridge and gantry cranes selection criteria related equipment under various anticipated conditions of use.

Found what you need?

Document preview — GB/T 24818.5-2009

National Standard of the People's Republic of China

ICS
53.020.20
Classification
J 80

Issued by: Standardization Administration of China

Contents

  • Preface
  • 1 Scope
  • 2 Normative references
  • 3 Channel
  • 4 Crane maintenance channel
  • 5 5 clearance
  • 6 Emergency exit
  • 7 Safety
  • Reference

Foreword

GB/T 24818 "Cranes access and security facilities" is divided into four parts.

--- Part 1. General;

--- Part 2. Mobile cranes;

--- Part 3. Tower cranes;

--- Part 5. Bridge and gantry cranes.

This section GB/T 24818 Part 5.

This part identical with ISO 11660-5:2001 "Cranes access and security facilities - Part 5. Bridge and gantry crane Machine "(in English).

This section is equivalent translation ISO 11660-5:1995.

For ease of use, this section also made the following editorial changes.

--- The term "this part of ISO 11660" with the words "GB/T 24818 in this section";

--- Delete foreword international standards;

--- Of ISO 11660-5:2001 references to other international standards, with the international standard has been adopted as a standard in place of the corresponding country;

--- ISO 11660-5:2001 Reference in ISO 4306-1:2007, by reference in Chapter 1, it will move it to Chapter 2 specification Sexual references, and to GB/T 6974.1.

This part is proposed by China Machinery Industry Federation.

This part of the National Standardization Technical Committee crane (SAC/TC227) centralized.

This section drafted by. DHI DCW Group Co., Ltd.

1 Scope

This section GB/T 24818 requirements by GB/T 6974.1 definition of bridge and gantry crane access and security facilities in the Special requirements, and gives the bridge and gantry cranes selection criteria related equipment under various anticipated conditions of use.

2 Normative references

The following documents contain provisions which, through reference GB/T 24818 in this section constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.

GB 5226.2 Safety of machinery electrical equipment Part 32. Requirements for hoisting machines (GB 5226.2-2002, IEC 60204-32:1998, IDT) GB/T 6974.1 crane terminology - Part 1. General terms (GB/T 6974.1-2008, ISO 4306-1:2007, IDT) GB/T 24818.1-2009 crane access and security - Part 1. General (ISO 11660-1:2008, IDT)

3 Channels

3.1 General

This section is a gateway to be installed on the ground or elevated rail bridge and gantry crane working channel, as well as the type of crane Routine and emergency maintenance, repair channel requirements.

3.2 Bridge crane plant or elevated track

3.2.1 Leading crane access platform

In the cab operated bridge and gantry cranes for the driver should access the access platform fixed to the support structure of the crane.

Table 1 Recommended given in the form of channels, should be consistent with GB/T 24818.1-2009 Table 6 shows the channel form and size.

Table 1 Recommended channel form

Channel height from the ground /Recommended channel form 1 to 15 stairs LADDER Ladders 15-25 staircase > 25 Electric channel stairs

3.2.2 Channel Platform

Leading to the crane should be normal channel access platform access. Channel entrances should be of the self-closing device to be protected, such as.

--- Within the open doors or gates;

--- Up and down or left and right sliding doors;

--- Vertical hinged fence.

GB/T 24818.5-2009/ISO 11660-5:2001

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 24818.5-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
7 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 24818.5-2009

$135.00