Valid

GB/T 24684.3-2009Crop protection equipment -- Test methods for the evaluation of cleaning systems -- Part 3: Internal cleaning of tank (English PDF)

植物保护机械 评价清洗系统的试验方法 第3部分:药液箱的内部清洗

Preview PDF

This is a limited preview

Buy now to download the full PDF (5 pages)

Need quotation for your management?

Get a formal quotation for GB/T 24684.3-2009 in 30 minutes.

Issued by

Standardization Administration of China

Level / Type

National · Recommended

Issue date

November 30, 2009

Implementation date

April 1, 2010

Scope

GB/T 24684.3-2009 is the English-translated version of 植物保护机械 评价清洗系统的试验方法 第3部分:药液箱的内部清洗.

GB/T 24684.3-2009 — This section GB/T 24684 specifies the cleaning system installed on the plant protection sprayer, tank for internal cleaning Performance test methods.

This section applies to plant protection and spraying liquid fertilizer suspended, towed and self-propelled agricultural sprayers. This section does not apply to drugs having direct injection sprayer system.

Found what you need?

Document preview — GB/T 24684.3-2009

National Standard of the People's Republic of China

ICS
65.060.40
Classification
B 91

Issued by: Standardization Administration of China

Contents

  • Foreword
  • Introduction
  • 1 Scope
  • 2 Terms and definitions
  • 3 Test conditions
  • 4 Test
  • 4.1 General Requirements
  • 4.2 Test Details

Foreword

GB/T 24684 "Standard Test Method for Evaluation of plant protection machinery and washing system" is divided into the following three parts.

--- Part 1. Internal sprayer machine cleaning;

--- Part 2. External cleaning of the sprayer;

--- Part 3. Internal tank cleaning.

This section is GB/T Part of 324,684.

This section identical with ISO 22368-3:2004 Test methods "plant protection machinery evaluation of cleaning systems - Part 3. tank Internal cleansing "(in English).

This section is equivalent translation ISO 22368-3:2004.

For ease of use, this section made the following editorial changes.

--- "ISO 22368-3:2004 this part" to "this Part";

--- Deleted international standards foreword;

--- With a decimal point "." As an alternative to the decimal point "." Appendix A of this section is normative appendix, Appendix B is an informative annex.

This part is proposed by China Machinery Industry Federation.

This part of the National Standardization Technical Committee (SAC/TC201) Agricultural machinery centralized.

This section drafted by. Chinese Academy of Agricultural Mechanization Sciences, Ministry of Agriculture, Nanjing Institute of Agricultural Mechanization, Modern Agricultural Equipment Technologies AG Limited.

Introduction

For the following reasons, plant protection sprayer cleaning becomes more and more important.

--- In order to avoid contamination of the environment and the operator;

--- Pesticide that may occur because of an accidental discharge causing crop injury, triggering fears of increased pesticide residues, or Caused by pesticides mixing several mutually exclusive.

In addition, the relevant industrial sector may need to provide development guidelines washing system to assess the level of technological development and future technology base.

GB/T 24684.1 and GB/T 24684.2 provisions of the relevant test methods and internal and external cleaning sprayer, to provide users Evaluation of internal and external cleaning system as well as the overall performance of a method to determine the future technical performance basis. This series of standards for the spray organs Key components provides a separate chapter (see GB/T 24684.3).

This section evaluation of cleaning a particular part of the system provides test methods in detail the results obtained may be improved and perfected cleaning systems Provide evidence.

GB/T 24684.3-2009/ISO 22368-3:2004 Plant protection machinery Test methods for the evaluation of cleaning systems Part 3. Internal tank cleaning WARNING. Users should be familiar with this part of the routine laboratory practice. This section related to the use of all possible security not addressed Wide issues. Users should make their own provisions appropriate safety and health practices and to ensure compliance with relevant national safety and environmental provisions.

1 Scope

This section GB/T 24684 specifies the cleaning system installed on the plant protection sprayer, tank for internal cleaning Performance test methods.

This section applies to plant protection and spraying liquid fertilizer suspended, towed and self-propelled agricultural sprayers.

This section does not apply to drugs having direct injection sprayer system.

2 Terms and definitions

The following terms and definitions apply to this section.

Sprayer for cleaning complex parts inside the tank.

3 Test conditions

Test should be carried out under the following conditions.

Test solution temperature. 5 °C ~ 25 °C.

Air temperature. 5 °C ~ 25 °C.

Relative humidity. > 30%.

4 Test

Safety precautions --- This method may cause environmental hazards, should comply with generally accepted preventive measures to avoid accidental discharge test solution Outside the test site. All operations should be ensured that the collection of the test solution and wash with water sprayers, or should pay attention to the discharged liquid Body will not harm the environment.

4.1 General Requirements

Appendix A and Part 3 of this chapter in the given conditions, you should use a 1% concentration of basic copper chloride suspension test. in case

It can be proved to have the same properties may also be used to test other liquid tracer.

4.2 Test Details

4.2.1 When the trial began, the first cleaning tank.

Then side agitator stirring the test liquid to fill the tank until the tank full. Should ensure that all internal surfaces (especially medicine chest Internal medicine and the upper surface of the lid) should be soaked in the test solution. Stirrer continued stirring 10min, remove the sprayer from the tank in three have Representative sample to check the concentration of the reference test liquid. Each sample shall be not less than the amount of 50ml, with respect to the reference concentration of the partial test liquid the difference should not exceed 5%.

4.2.2 Analog spray working condition emptying the tank. Such as opening the mouth of the inlet nozzle paragraphs 1, so that the amount of liquid discharged from the equal There discharge nozzle at the total amount of liquid, the liquid tank through the remaining portion of the outlet discharge.

GB/T 24684.3-2009/ISO 22368-3:2004

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 5 pages — is available in the English PDF.

How to Download GB/T 24684.3-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
5 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 24684.3-2009

$95.00