Valid

GB/T 23869-2009Method for determination of the total mercury in pollen (English PDF)

花粉中总汞的测定方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (6 pages)

Need quotation for your management?

Get a formal quotation for GB/T 23869-2009 in 30 minutes.

Issued by

Standardization Administration of China

Level / Type

National · Recommended

Issue date

May 26, 2009

Implementation date

September 1, 2009

Scope

GB/T 23869-2009 is the English-translated version of 花粉中总汞的测定方法.

GB/T 23869-2009 — This standard specifies the method for determination of total mercury pollen. This standard applies to the determination of total mercury content in pollen. The standard lower limit of detection 0.5µg/kg.

Found what you need?

Document preview — GB/T 23869-2009

National Standard of the People's Republic of China

ICS
67.180.10
Classification
X 04

Issued by: Standardization Administration of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 PRINCIPLE OF THE METHOD
  • 4 Reagents
  • 5 Instruments
  • 6 Step, Analysis
  • 6.1 Sample Pretreatment
  • 6.2 Sample Microwave Digestion

Foreword

The standard proposed by China Federation of Supply and Marketing Cooperatives.

This standard is under the jurisdiction of the national bee standardization working group.

This standard was drafted. People's Republic of China Jiangsu Entry-Exit Inspection and Quarantine Bureau, Jiangsu Laoshan Biotechnology Co., Ltd., Nanjing University, Bee Research Institute, Chinese Academy of Agricultural Sciences.

Drafters of this standard. Shen Chong-yu, Li Gonghai, Chen Kun, Wu Bin, Ding Tao, practicing Hong Zhen, Zhou Jinhui, Li Yi, Wang Peng.

Determination of total mercury pollen

1 Scope

This standard specifies the method for determination of total mercury pollen.

This standard applies to the determination of total mercury content in pollen.

The standard lower limit of detection 0.5µg/kg.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.

GB/T 6682 analytical laboratory use specifications and test methods (GB/T 6682-2008, ISO 3696. 1987, MOD)

3 PRINCIPLE OF THE METHOD

After the sample was heated acid digestion in acidic medium, the sample Mercury is potassium borohydride (KBH4) reduction of mercury atoms by a carrier gas (argon Gas) into the atomizer at a special mercury hollow cathode lamp irradiation, emit fluorescence characteristic wavelength, the fluorescence intensity and the concentration of mercury being Ratio, compared with standard series quantitation.

4 Reagents

Unless otherwise indicated, the reagents used were of analytical grade water as a water GB/T 6682 regulations.

4.1 nitrate (excellent pure).

4.2 Hydrogen peroxide (30%).

4.3 Potassium hydroxide solution (5g/L). Weigh 5.0g of potassium hydroxide and diluted with deionized water to 1L, mix.

4.4 solution of potassium borohydride (1g/L). Weigh 1.0g of potassium borohydride, dissolved in 1L potassium hydroxide solution (5g/L), the mix, now with the current.

4.5 thiourea ascorbic acid solution (10g/L). Weigh 10g and 10g ascorbic acid, thiourea, with a 5% (volume fraction) nitric acid solution it was diluted to 1L, and mix.

4.6 mercury standard solution. 1000µg/mL.

4.7 mercury standard solution. lessons mercury standard stock solution 1.0mL in 100mL flask, add nitric acid 2mL, with water to volume, is 10µg/mL. Then it was diluted to 100ng/mL mercury standard solution, this solution is valid 60d.

5 Instruments

5.1 pairs of channel Atomic Fluorescence Spectrometer.

5.2 microwave digestion (digestion with high pressure tank).

6 Step, Analysis

6.1 Sample Pretreatment

6.1.1 Sampling and sample preparation process, should be taken not to sample contamination.

6.1.2 The sample should be stored in airtight and dry container.

6.2 Sample Microwave Digestion

Weigh 0.5g sample in the digestion tank, add 3mL of nitric acid and hydrogen peroxide 1mL, according to Table 1 after the end of the digestion procedure, remove spent DI water to 25mL; while doing a reagent blank test.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 23869-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
6 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 23869-2009

$105.00