GB/T 23642-2026Electrical insulating materials and systems - Electrical measurement of partial discharges (PD) under short rise time and repetitive voltage impulses (English PDF)

电气绝缘材料和系统 瞬时上升和重复电压冲击条件下的局部放电(PD)电气测量

Preview PDF

This is a limited preview

Buy now to download the full PDF (20 pages)

Need quotation for your management?

Get a formal quotation for GB/T 23642-2026 in 30 minutes.

Issued by

State Administration for Market Regulation

Level / Type

National · Recommended

Issue date

July 30, 2026

Implementation date

February 1, 2027

Scope

GB/T 23642-2026 is the English-translated version of 电气绝缘材料和系统 瞬时上升和重复电压冲击条件下的局部放电(PD)电气测量.

GB/T 23642-2026 — This document describes the localized impacts that occur when an electrical insulation system (EIS) is subjected to repetitive voltage surges from power electronic equipment.

Offline electrical measurements of partial discharge (PD). This document applies to EIS (Electronic Information System) powered by power electronic equipment, such as motors, inductive reactors, wind turbines, and power electronic modules.

Note. When using this document for specific products, additional procedures may be required. This document does not apply to optical or ultrasonic-based PD detection methods or non-repetitive voltage surges (such as lightning strikes or switching equipment interruption surges).

Found what you need?

Document preview — GB/T 23642-2026

National Standard of the People's Republic of China

ICS
17.220.99, 29.035.01, 29.080.30
Classification
K 15
Replacing
GB/T 23642-2017

Issued by: State Administration for Market Regulation

Contents

  • Preface
  • Introduction
  • 1 Scope
  • 2 Normative References
  • 3 Terms and Definitions
  • 4 Measurement of partial discharge pulses during repeated short-duration voltage surges and comparison with power frequency measurements. 3.
  • 6 Measuring instruments
  • 7 Check the sensitivity of the PD measuring equipment and high-voltage source generator. 9.
  • 8 Test procedure for the increase and decrease of repetitive impulse voltage amplitude
  • 9 Test Report
  • Appendix A (Informative) Voltage Surge Suppression Required for Coupling Devices
  • Appendix B (Informative) Extracting PD Pulses from Voltage Impulse Sources Using Filtering Techniques
  • Appendix C (Informative) Results of Parallel Tests for Measuring RPDIV
  • Appendix D (Informative) Example 19 of noise levels from actual PD detectors
  • References
  • Correlation

Foreword

This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents".

Drafting.

This document replaces GB/T 23642-2017 "Electrical Insulation Materials and Systems - Local Insulation under Instantaneous Rise and Repetitive Voltage Impulses".

The main technical changes in "Electrical Measurement of Discharge (PD)" compared to GB/T 23642-2017, apart from structural adjustments and editorial modifications, are as follows.

---The scope of application for power electronic modules has been expanded (see Chapter 1);

---The definition of the term "partial discharge" has been revised to include the addition that "this discharge may or may not occur near a conductor." the description of "" (see 3.2, 2017 edition);

---The definition of the term "unipolar impact" has been changed (see 3.7, 2017 edition of 3.7);

---GB/T 7354-2003 has been changed to IEC 60270 (see 4.1, 2017 edition 4.1);

---IEC 60034 (all parts) has been changed to IEC 60034-18-1 (see 4.3.2, 2017 edition of 4.3.2);

---The rise time frequency range has been changed to 0.02µs~1µs, and the triangular wave is recommended as the preferred waveform (see Table 1, Table 1 in the 2017 version);

--- Charge measurement has been removed (see 5.2.5 in the 2017 version);

---The source control gate technology has been removed (see 5.3 in the 2017 version).

This document is equivalent to IEC TS61934:2024 "Electrical insulation materials and systems under transient rise and repetitive voltage impulse conditions".

"Electrical Measurement of Partial Discharge (PD)". The document type has been changed from an IEC technical specification to a recommended national standard in my country.

The following minimal editorial changes have been made to this document.

---The terminology source has been changed from IEC 60270 to GB/T 7354-2018, and IEC 62068:2013 to GB/T 22566-2017;

---Reference IEC 62068:2013 has been changed to GB/T 22566-2017, and reference GB/T 7354-2018 has been added.

Please note that some content in this document may involve patents. The issuing organization of this document assumes no responsibility for identifying patents.

This document was proposed by the China Electrical Equipment Industry Association.

This document is under the jurisdiction of the National Technical Committee on Standardization of Electrical Insulation Materials and Insulation Systems (SAC/TC301).

Introduction

The development of power electronics is intertwined with control theory and semiconductor technology. Switching operation is one of the core characteristics of power electronic control.

To achieve higher efficiency and smoother operation, devices such as insulated-gate bipolar transistors (IGB Ts) often have switching times shorter than microseconds.

The application of wide-bandgap devices (such as silicon carbide-based devices) can produce transient processes with rise times on the order of tens of nanoseconds. For example...

This short rise time can trigger transient overvoltage pulses or surges in the system. When these voltage pulses reach the breakdown strength of the air gap, Partial discharge (PD) may occur. Furthermore, these pulses exhibit heavy [symbols] due to power electronic modulation (e.g., pulse width modulation (PWM)).

Reversibility characteristics. Given that partial discharge can cause performance degradation of electrically insulating components in a system, it is a critical parameter that needs to be measured.

one.

Instantaneous rise of electrical insulation materials and systems Local under repetitive voltage impact conditions Discharge (PD) electrical measurement

1 Scope

This document describes the localized impacts that occur when an electrical insulation system (EIS) is subjected to repetitive voltage surges from power electronic equipment.

Offline electrical measurements of partial discharge (PD).

This document applies to EIS (Electronic Information System) powered by power electronic equipment, such as motors, inductive reactors, wind turbines, and power electronic modules.

Note. When using this document for specific products, additional procedures may be required.

This document does not apply to optical or ultrasonic-based PD detection methods or non-repetitive voltage surges (such as lightning strikes or switching equipment interruption surges).

2 Normative references

The contents of the following documents, through normative references within the text, constitute essential provisions of this document. Dated citations are not included.

For references to documents, only the version corresponding to that date applies to this document; for undated references, the latest version (including all amendments) applies.

This document.

Note. GB/T 7354-2018 High Voltage Testing Techniques - Partial Discharge Measurement (IEC 60270:2000, MOD)

3 Terms and Definitions

The following terms and definitions apply to this document.

The URLs for the terminology databases maintained by ISO and IEC for standardization are as follows.

Test voltage surges are used to evaluate power electronic devices with a certain carrier or drive frequency due to switching impulses.

Partial discharge (PD) the insulation between conductors is only partially bridged by electrical discharge, and this discharge may or may not occur near the conductor.

[Source. GB/T 7354-2018, 3.1, with modifications] 3.3 the current pulse measured at the end of the test sample when partial discharge occurs inside the sample.

Note 1.To achieve the testing purpose, the pulse is measured using an appropriate detection circuit connected in the test circuit.

Note 2.According to this document, the current or voltage signal detected at the output terminal is related to the PD pulse at the input terminal.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 23642-2026

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
20 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 23642-2026

$365.00