Valid

GB/T 22794-2017Type F and type B residual current operated circuit-breakers with and without integral overcurrent protection for household and similar uses (English PDF)

家用和类似用途的不带和带过电流保护的F型和B型剩余电流动作断路器

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 22794-2017 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Recommended

Issue date

December 29, 2017

Implementation date

July 1, 2018

Scope

GB/T 22794-2017 is the English-translated version of 家用和类似用途的不带和带过电流保护的F型和B型剩余电流动作断路器.

GB/T 22794-2017 — The scope of IEC 61008-1 and IEC 61009-1 applies with the following additions. This Standard specifies requirements and tests for Type F and Type B RCDs (Residual Current Devices).

Requirements and tests given in this Standard are supplemented the requirements of Type A residual current devices. This Standard can only be used together with IEC 61008-1 and IEC 61009-1.

Found what you need?

Document preview — GB/T 22794-2017

National Standard of the People's Republic of China

ICS
29.120; 29.120.50
Classification
K 31

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Foreword...3
  • Introduction...6
  • 1 Scope...7
  • 2 Normative References...8
  • 3 Terms and Definitions...8
  • 4 Classification...9
  • 5 Characteristics...10
  • 6 Marking and Other Product Information...12
  • 7 Standard Conditions for Operation in Service and for Installation...12
  • 8 Conditions for Construction and Operation...13
  • 9 Tests...15

Foreword

This Standard was drafted as per the rules specified in GB/T 1.1-2009.

This Standard replaced GB/T 22794-2008 Type B Residual Current Operated Circuit-

Breakers with and without Integral Overcurrent Protection for Household and Similar

Uses (Type B RCCBs and Type B RCBOs). Compared with GB/T 22794-2008, this

Standard has the major changes as follows.

--- Modified the introduction.

--- Modified the scope, this standard covers Type F RCD.

--- Added the definition of Type F residual current device in 3.2.

--- Supplemented the according to behavior in presence of d.c. components in 4.1.

--- Supplemented the characteristics of Type F residual current device in 5.1.

--- Modified and supplemented the characteristics of Type B residual current device

in 5.2.

--- Added Type F RCD sign in 6.1.

--- Modified Type B RCD sign in 6.2.

--- Added Type F and Type B RCD requirements in 8.1.

--- Supplemented the characteristics of three-pole and four-pole Type B RCD in the

case of two-pole power supply only in 8.2.1.7.

--- Added the RCD performance under the role of surge residual current in 8.3.1;

the RCD performance under the role of in-rush residual current in 8.3.2; the

performance when pulsating direct residual current superimposes 10mA

continuous smooth direct residual current in 8.3.3.

--- Added Type F and Type B RCD tests in 9.1.

--- Supplemented the correct operation of three-pole and four-pole Type B RCD

when only powered by two-pole in 9.2.3.

--- Added an example of a test circuit to verity proper operation when single-phase

supply motor speed control device generates residual sinusoidal AC current with

multiple frequency components in Figure 1.

--- Added a test circuit to verify RCD performance when in-rush current occurs in

Figure 2.

--- Added Appendix A Quantity of Specimens and Test Procedures for Type F RCCB

Compliance Verification; and Appendix B Quantity of Specimens and Test

Procedures for Type F RCBO Compliance Verification.

--- Modified Appendix C Quantity of Specimens and Test Procedures for Type B

RCCB Compliance Verification; and Appendix D Quantity of Specimens and Test

Procedures for Type B RCBO Compliance Verification.

--- Modified Appendix E Type F and Type B RCD Routine Tests.

The translation method of this Standard equivalently adopts IEC 62423.2009 Type F

and Type B Residual Current Operated Circuit-breakers with and without Integral

Overcurrent Protection for Household and Similar Uses.

The Chinese document that are consistent with the corresponding international

documents that are normative references in this Standard are as follows.

--- GB/T 13870.1-2008 Effects of Current on Human Beings and Livestock - Part 1.

General Aspects (IEC/TS 60479-1.2005, IDT)

--- GB/T 13870.2-2016 Effects of Current on Human Beings and Livestock - Part 2.

Special Aspects (IEC/TS 60479-2.2007, IDT)

--- GB/T 16916.1-2014 Residual Current Operated Circuit-Breakers without Integral

Overcurrent Protection for Household and Similar Uses (RCCB) - Part 1.General

Rules (IEC 61008-1.2012, MOD)

--- GB/T 16917.1-2014 Residual Current Operated Circuit-Breakers with Integral

Overcurrent Protection for Household and Similar Uses (RCBOs) - Part 1.

General Rules (IEC 61009-1.2012, MOD)

This Standard was proposed by China Electrical Equipment Industrial Association.

This Standard shall be under the jurisdiction of National Technical Committee for

Standardization of Low-Voltage Electrical Appliance (SAC/TC 189).

Drafting organizations of this Standard. Shanghai Electrical Apparatus Research

Institute, Shanghai Dianke Electric Appliance Technology Co., Ltd., Zhejiang Chint

Electrics Co., Ltd., Shanghai Liangxin Electrical Co., Ltd., Shanghai Siemens Circuit

Protection Systems Ltd., Schneider Electric (China) Co., Ltd., Zhongshan Kaper

Electrical Co., Ltd., Wuxi Legrand Low Voltage Electrical Co., Ltd., Foretech Elec. App.

(Jiangsu) Co., Ltd., Beijing Abb Low-voltage Installation Materials Co., Ltd., Sassin

International Electric Shanghai Co., Ltd., China Electric power Research Institute,

Hangzhou Qianlong Electronic Co., Ltd., Zhejiang Fang Yuan Electric Equipment Test

Co., Ltd., General Electric Enterprise Development (Shanghai) Co., Ltd., Shanghai

Jingyi Electric Apparatus Factory Co., Ltd., People Electric Appliance Group Co., Ltd.,

Changan Group Co., Ltd., Zhejiang Qianlong Technology Co., Ltd., and Yuyao Jiarong

Electronic & Electric Appliance Co., Ltd.

Chief drafting staffs of this Standard. Zhou Jigang, Liu Jinyan, Ge Weijun, Fan Jianguo,

Xiong Houyu, Zhou Lei, Zou Jianhua, Si Yingge, Fu Kai, Xue Han, Jiang Wei, Su Hanlin,

Han Shaigen, Zhong Fangqiang, Wang Guozhogn, Zou Xiping, Gu Dekang, Bao

Zhizhou, Wang Xuchuan, Lu Yueyou, and Qian Jiaocan.

The historical editions replaced by this Standard are as follows.

--- GB 22794-2008, GB/T 22794-2008.

1 Scope

The scope of IEC 61008-1 and IEC 61009-1 applies with the following additions.

This Standard specifies requirements and tests for Type F and Type B RCDs (Residual

Current Devices). Requirements and tests given in this Standard are supplemented

the requirements of Type A residual current devices. This Standard can only be used

together with IEC 61008-1 and IEC 61009-1.

2 Normative References

The following documents are essential to the application of this document. For the

dated documents, only the versions with the dates indicated are applicable to this

document; for the undated documents, only the latest version (including all the

amendments) are applicable to this document.

IEC/TS 60497-1 Effects of Current on Human Beings and Livestock – Part 1.

General Aspects

3 Terms and Definitions

For the purposes of this document, the following terms and definitions apply.

residual current device for which tripping is ensured as for Type F according to this

Standard and in addition.

4 Classification

According to IEC 61008-1 or IEC 61009-1, as applicable with the following addition.

5 Characteristics

Residual current device for which tripping is ensured as for Type F and in addition.

6 Marking and Other Product Information

Add the following symbol adjacent to the symbol for Type A, e.g.

; alternatively, the following symbol may be used.

7 Standard Conditions for Operation in Service and for Installation

According to IEC 61008-1 or IEC 61009-1, as applicable.

8 Conditions for Construction and Operation

RCDs shall show adequate resistance against unwanted tripping in case of current

surges to earth due to the loading of the capacitances of the installation and the current

surges to earth due to flashover in the installation.

RCDs shall adequately withstand inrush residual currents with a maximum duration of

10 ms which can occur in case of switching on electronic equipment or EMC-filters.

9 Tests

Tests are carried out to verify the break time of the RCD, the test current being

calibrated at 5 times the upper limit value given in Table 4.

The test switch S1 and the RCD being in the closed position, the residual current is

suddenly established by closing the test switch S2.

Annex A

(Normative)

Number of Samples to be Submitted and Test Sequences to be Applied

for Verification of Conformity for Type F RCCBs

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 22794-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 22794-2017

$145.00