GB/T 223.87-2018Iron,steel and alloy—Determination of calcium and magnesium—Inductively coupled plasma mass spectrometric method (English PDF)
钢铁及合金 钙和镁含量的测定 电感耦合等离子体质谱法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 223.87-2018 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
May 14, 2018
Implementation date
February 1, 2019
Scope
GB/T 223.87-2018 is the English-translated version of 钢铁及合金 钙和镁含量的测定 电感耦合等离子体质谱法.
GB/T 223.87-2018 is the part of the GB/T 223 series that determines calcium and magnesium in iron, steel and alloys by inductively coupled plasma mass spectrometry.
It covers calcium mass fractions from 0.0002% to 0.0035% and magnesium from 0.0003% to 0.05%.
The sample is dissolved in hydrochloric, nitric and hydrofluoric acids, with perchloric acid fuming where needed, and the solution is pumped into the spectrometer; calibration solutions are matched to the sample matrix and acids, and an internal standard compensates for instrument drift and matrix effects.
The standard lists the high-purity reagents and standard solutions, the instruments, sampling, the dissolution routes for carbon and low-alloy steels and for high-carbon and alloy steels, the calibration solutions, result calculation, precision and the test report. It was issued on 14 May 2018 and has applied since 1 February 2019.
Found what you need?
Document preview — GB/T 223.87-2018
National Standard of the People's Republic of China
- ICS
- 77.080.01
- Classification
- H 11
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative References4
- 3 Principle4
- 4 Reagents5
- 5 Instruments and Equipment7
- 6 Sampling and Sample Preparation8
- 7 Experimental Procedures8
- 8 Result Calculation11
- 9 Precision11
- 10 Test Report12
- Appendix A (informative appendix)13
- Appendix B (informative appendix)14
1 Scope
This Part in GB/T 223 specifies methods of determining calcium and magnesium content through inductively coupled plasma mass spectrometric method.
This Part is applicable to the determination of calcium (mass fraction. 0.0002% ~ 0.0035%) and magnesium (mass fraction. 0.0003% ~ 0.05%) in iron, steel and alloy.
2 Normative References
The following documents are indispensable to the application of this Standard. In terms of references with a specified date, only versions with a specified date are applicable to this Standard. The latest version (including all the modifications) of references without a specified date is also applicable to this Standard.
GB/T 6379.1 Accuracy (Trueness and Precision) of Measurement Methods and Results - Part 1. General Principles and Definitions (GB/T 6379.1-2004, ISO 5725-1:1994, IDT)
GB/T 6379.2 Accuracy (Trueness and Precision) of Measurement Methods and Results - Part 2. Basic Method for the Determination of Repeatability and Reproducibility of a Standard Measurement Method (GB/T 6379.2-2004, ISO 5725-2:1994, IDT)
GB/T 6682 Water for Analytical Laboratory Use - Specification and Test Methods (GB/T 6682-2008, ISO 3696. 1987, MOD)
GB/T 12806 Laboratory Glassware - One-mark Volumetric Flasks (GB/T 12806-2011, ISO 1042:1998, NEQ)
GB/T 12808 Laboratory Glassware - One-mark Pipettes
GB/T 20066 Steel and Iron - Sampling and Preparation of Samples for the Determination of Chemical Composition (GB/T 20066-2006, ISO 14284:1996, IDT)
3 Principle
Dissolve reagent in the mixed acid of hydrochloric acid, nitric acid and hydrofluoric acid.
If necessary, adopt perchloric acid to generate fumes. After dilution, import the sample solution into inductively coupled plasma mass spectrometer with a peristaltic pump.
During the operation of the inductively coupled plasma mass spectrometer, measure the mass spectrometry signal intensity of the element.
Conduct matrix matching of calibration blank, calibration solution, and main elements in the sample to be tested, and acid adopted for reagent decomposition. Adopt internal standard to compensate the instrument's drifting effect and matrix effect.
4 Reagents
Unless it is otherwise indicated, high-purity reagent (mass fraction of calcium and magnesium < 0.0001%) or reagent with equivalent purity, and first-grade water stipulated in GB/T 6682 shall be adopted in analysis. If the requirements cannot be satisfied, use an acid purification unit (5.3) to purify the reagents.
4.1 Hydrochloric acid, rho = 1.19 g/mL.
4.2 Nitric acid, rho = 1.42 g/mL.
4.3 Hydrofluoric acid, rho = 1.19 g/mL.
4.4 Perchloric acid, rho = 1.67 g/mL.
4.5 Calcium standard stock solution, 1,000 µg/mL
Weigh-take 2.4972 g of calcium carbonate (mass fraction >= 99.99%) that is already dried at 110 °C for 1 h and cooled down to room temperature in a dryer. Place it in 400 mL beaker; add 100 mL of hydrochloric acid (1+1) to dissolve it. After cooling it down, transfer it into 1,000 mL volumetric flask. Use water to dilute to the constant volume; thoroughly mix it.
1 mL of this solution contains 1,000 µg of calcium.
4.6 Magnesium standard stock solution, 1,000 µg/mL
Weigh-take 1.6582 g of magnesium oxide (mass fraction >= 99.99%) that is already burnt at 850 °C for 30 min and cooled down to room temperature in a dryer. Place it in 400 mL beaker; add 100 mL of hydrochloric acid (1+1). After heating it up and dissolving it, cool it down to room temperature; transfer it into 1,000 mL volumetric flask.
Use water to dilute to the constant volume; thoroughly mix it.
1 mL of this solution contains 1,000 µg of magnesium.
4.7 Mixed standard solution of calcium and magnesium
4.7.1 Mixed standard solution of calcium and magnesium, 100 µg/mL
7 Experimental Procedures
7.2 Blank Test
Conduct blank test in accordance with the sample.
7.3 Determination
7.3.1 Preparation of sample solution
In terms of carbon steel and low-alloy steel sample. place the sample (7.1) in 100 mL quartz beaker. Add 10 mL of water and 5 mL of nitric acid (4.2) [add 0.5 mL of hydrofluoric acid (4.3) to high-silicon sample], heat it up till it boils. After eliminating nitrogen oxide, take it down; cool it down, then, transfer it into 100 mL plastic volumetric flask; add 1.0 mL of internal standard solution of scandium (4.8.3). Use water to dilute to the constant volume, then, thoroughly mix it for later determination.
In terms of high-carbon steel and alloy steel sample. place the sample (7.1) in 100 mL quartz beaker. Add 3 mL of hydrochloric acid (4.1) and 1 mL of HNO3 (4.2); use heating plate to heat it up till it boils. Add 2 mL of perchloric acid (4.4), heat it up till it begins to fume and stable perchloric acid fume reflux is formed around the bottle mouth or on the wall. Continue to heat it up, till white perchloric acid fume vanishes. Cool it down, then, add 3 mL of hydrochloric acid (4.1) and 1 mL of HNO3 (4.2); conduct low-temperature heating till salt is dissolved. If there are hydrolysable elements in alloy steel, add 0.5 mL of hydrofluoric acid (4.3) for complexation. Cool it down, then, transfer to 100 mL plastic volumetric flask; add 1.0 mL of internal standard solution of scandium (4.8.3). Use water to dilute to the constant volume, then, thoroughly mix it for later determination.
NOTE: microwave digestion system can also be adopted for the preparation of sample solution, but the laboratory shall determine an optimized experimental plan in accordance with conditional experiments.
7.3.2 Preparation of calibration solution
Respectively transfer 0, 0.20 mL, 0.50 mL, 1.00 mL, 2.00 mL and 5.00 mL of mixed standard solution of calcium and magnesium (4.7.3), and 1.00 mL, 2.00 mL and 5.00 mL of mixed standard solution of calcium and magnesium (4.7.2) in 9 plastic volumetric flasks (100 mL). Respectively add 10 mL of Fe matrix solution (4.11) and 1.00 mL of scandium internal standard solution (4.8.3). Add acid that is consistent with sample dissolution; use water to dilute to the constant volume, then, thoroughly mix it. Solution that does not contain the mixed standard solution of calcium and magnesium is calibration blank solution.
7.3.3 Preparation of instrument
Before analysis, ignite plasma; pre-heat it for 30 min ~ 60 min in accordance with the requirements in the instruction for use to stabilize the instrument. During this process, pump in water or mass spectrometer cleaning solution (4.10) to rinse nebulizer and […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 6379.1Accuracy (trueness and precision) of measurement methods and results -- Part 1: General principles and definitions
- GB/T 6379.2Accuracy (trueness and precision) of measurement methods and results - Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
- GB/T 6682Water for analytical laboratory use - Specification and test methods
- GB/T 12806Laboratory glassware -- One-mark volumetric flasks
- GB/T 12808Laboratory glassware - One mark pipettes
- GB/T 20066Steel and iron -- Sampling and preparation of samples for the determination of chemical composition
Similar standards
How to Download GB/T 223.87-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 12806-2011 — Laboratory glassware -- One-mark volumetric flasks
GB/T 12808-2015 — Laboratory glassware - One mark pipettes
GB/T 20066-2006 — Steel and iron -- Sampling and preparation of samples for the determination of chemical composition
Secure payment via Stripe
Payments accepted
GB/T 223.87-2018
$125.00