GB/T 22193-2008Electrical installations in ships -- Equipment -- Semiconductor convertors (English PDF)
船舶电气设备 设备 半导体变流器
This is a limited preview
Buy now to download the full PDF (4 pages)
Need quotation for your management?
Get a formal quotation for GB/T 22193-2008 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
July 16, 2008
Implementation date
April 1, 2009
Scope
GB/T 22193-2008 is the English-translated version of 船舶电气设备 设备 半导体变流器.
GB/T 22193-2008 — This standard applies to the use of such diodes, and reverse blocking three-terminal thyristor semiconductor rectifier element marine static converter. Converter can So the AC to DC and DC-AC, DC-DC and AC-AC.
Found what you need?
Document preview — GB/T 22193-2008
National Standard of the People's Republic of China
- ICS
- 47.020.60
- Classification
- U 60
Issued by: Standardization Administration of China
Contents
- Foreword
- 1 Scope
- 2 General requirements
- 3 Cooling arrangement
- 4 Selenium rectifying elements
- 5 Accessibility
- 6 Conditions
- 7 Applications
- 7.1 Forced cooling
- 7.2 Interaction with the power supply or the load system
Foreword
This standard is identical with IEC 60092-304:1995 "Electrical installations in ships - Part 304. Equipment - Semiconductor convertors" (in English).
This standard is equivalent translation IEC 60092-304:1995.
For ease of use, this standard made the following editorial changes.
--- "This International Standard" be replaced by "this standard";
"." --- With a decimal point instead of a comma as the decimal point, "";
--- Delete international standards preface, introduction;
--- Of expression in accordance with the provisions of GB/T 1.1-2000 made changes.
The standard proposed by China State Shipbuilding Corporation.
This standard by the National Standardization Technical Committee boat ocean.
This standard was drafted. Technical and Economic Research Institute of China Shipbuilding Industry.
1 Scope
This standard applies to the use of such diodes, and reverse blocking three-terminal thyristor semiconductor rectifier element marine static converter. Converter can So the AC to DC and DC-AC, DC-DC and AC-AC.
2 General requirements
Semiconductor convertors shall comply with the relevant provisions of the following publications, and should be in accordance with this standard and IEC 60092 Parts of other additional Provisions.
IEC 60146 Semiconductor converters (attached 1st Amendment) Semiconductor convertors IEC 60146A 1st Addition. Chapter 7. converter equipment and components mark Semiconductor convertors IEC 60146-2 Part 2. Semiconductor self-commutated converter Semiconductor convertors IEC 60146-3 Part 3. Semiconductor direct DC converter (chopper direct converter) IEC 60119 polycrystalline semiconductor rectifier stack and rectifier equipment Recommendations
3 Cooling arrangement
3.1 Semiconductor convertors is preferably a dry air-cooled.
3.2 immersion semiconductor converters should be sealed. If ventilation measures, it should be equipped with appropriate desiccant.
3.3 pairs immersion semiconductor converters should consider configuring a liquid over-temperature alarm and pneumatic protection device.
NOTE. Installation Notes See IEC 60092-401 "Installation and test of completed" in Chapter 16.
4 Selenium rectifying elements
Even small amounts of mercury can damage the anti-fogging agent type selenium rectifying elements, and therefore does not allow the use of mercury selenium rectifying element type anti-fogging agent.
5 Accessibility
Semiconductor convertors group or member should enable mounting a semiconductor device is removed without having to break up the entire converter.
6 Conditions
6.1 Semiconductor convertors conditions of use shall apply IEC 60092-101 "Definitions and general requirements" provisions (such as ambient temperature).
6.2 If the converter equipment needs to be dried to facilitate maintenance and inspection, then heating should be particularly careful to prevent it from exceeding the maximum allowable temperature Temperature rise limit.
7 Applications
7.1 Forced cooling
Such as the use of forced cooling circuits should be designed to maintain effective only when cooled, variable flow reactor to power up or remain charged.
7.2 Interaction with the power supply or the load system
7.2.1 Precautions should be taken to prevent over-current or load due to a power system disturbance caused by or overvoltage (if the load operation can be regenerated, further it should include regenerative power) harmful effects on the converter equipment.
GB/T 22193-2008/IEC 60092-304:1995
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.
Referenced standards
How to Download GB/T 22193-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
Secure payment via Stripe
Payments accepted
GB/T 22193-2008
$85.00