GB/T 21546-2008Critical current measurement -- DC critical current of Nb-Ti composite superconductors (English PDF)
铌钛复合超导体的直流临界电流测量
This is a limited preview
Buy now to download the full PDF (14 pages)
Need quotation for your management?
Get a formal quotation for GB/T 21546-2008 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
March 31, 2008
Implementation date
November 1, 2008
Scope
GB/T 21546-2008 is the English-translated version of 铌钛复合超导体的直流临界电流测量.
GB/T 21546-2008 — This standard applies to the determination of copper-Super ratio greater than 1 DC critical current of Cu/Nb-Ti composite superconductors, are equally applicable to the determination of niobium titanium wire core diameter greater than 1��m, Copper-Ultra ratio greater than 0.
9, copper-nickel alloy-superconductor ratio is greater than 0. 2 Cu/Cu Ni/Nb-Ti superconducting wire DC critical current.
Needed due to the Cu/Nb-Ti composite superconductors and copper/copper-nickel/niobium titanium superconductor critical current two slightly different test methods, the standard Annex C (normative) will introduce the measure copper/copper-nickel/niobium titanium superconductor Special to comply.
This standard test method is applicable under standard test conditions in which the magnetic superconductor is less than or equal to 0. 7 times the upper critical field, critical current of less than 1000A, n is greater than the superconductor 12.
Measurement, the sample should be immersed in liquid helium at a known temperature. Conductor should be tested for the integration of superconducting wire circular or rectangular cross-section, the cross-sectional area of ??less than 2 mm 2.
The sample should have a helical coil geometry. This standard is also given in daily testing of the experimental method allowed deviation and other specifically defined.
The critical current is greater than 1000A or greater than 2 mm 2 cross-sectional area of ??the conductor can also use this method of measurement, but the measurement uncertainty will increase, and the self-field effect is more pronounced.
Furthermore, in order to maintain a simple and relatively low measurement uncertainty, this standard does not involve special sample shape for large conductor cross-section may be more suitable.
Found what you need?
Document preview — GB/T 21546-2008
National Standard of the People's Republic of China
- ICS
- 77.040.01
- Classification
- H 21
Issued by: Standardization Administration of China
Contents
- What this standard covers1
- Document data2
- Standards quoted by this document3
What this standard covers
This standard applies to the determination of copper-Super ratio greater than 1 DC critical current of Cu/Nb-Ti composite superconductors, are equally applicable to the determination of niobium titanium wire core diameter greater than 1µm, Copper-Ultra ratio greater than 0. 9, copper-nickel alloy-superconductor ratio is greater than 0. 2 Cu/Cu Ni/Nb-Ti superconducting wire DC critical current. Needed due to the Cu/Nb-Ti composite superconductors and copper/copper-nickel/niobium titanium superconductor critical current two slightly different test methods, the standard Annex C (normative) will introduce the measure copper/copper-nickel/niobium titanium superconductor Special to comply. This standard test method is applicable under standard test conditions in which the magnetic superconductor is less than or equal to 0. 7 times the upper critical field, critical current of less than 1000A, n is greater than the superconductor 12. Measurement, the sample should be immersed in liquid helium at a known temperature. Conductor should be tested for the integration of superconducting wire circular or rectangular cross-section, the cross-sectional area of ??less than 2 mm 2. The sample should have a helical coil geometry. This standard is also given in daily testing of the experimental method allowed deviation and other specifically defined. The critical current is greater than 1000A or greater than 2 mm 2 cross-sectional area of ??the conductor can also use this method of measurement, but the measurement uncertainty will increase, and the self-field effect is more pronounced. Furthermore, in order to maintain a simple and relatively low measurement uncertainty, this standard does not involve special sample shape for large conductor cross-section may be more suitable. This standard measurement method given through appropriate modifications applicable to other types of composite superconducting wire measuring critical current.
Document data
International classification (ICS): 77.040.01.
Chinese classification (CCS): H21.
Estimated length of the Chinese original: 21,276 words.
Adopted international standard: IEC 61788-1-2006, IDT.
Standards quoted by this document
GB/T 13811-2003
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 14 pages — is available in the English PDF.
Referenced standards
How to Download GB/T 21546-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
Secure payment via Stripe
Payments accepted
GB/T 21546-2008
$399.00