GB/T 20441.3-2010Electroacoustics -- Measurement microphone -- Part 3: Primary method for free-field calibration of laboratory standard microphones by the reciprocity technique (English PDF)
电声学 测量传声器 第3部分:采用互易技术对实验室标准传声器的自由场校准的原级方法
This is a limited preview
Buy now to download the full PDF (12 pages)
Need quotation for your management?
Get a formal quotation for GB/T 20441.3-2010 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
December 1, 2010
Implementation date
May 1, 2011
Scope
GB/T 20441.3-2010 is the English-translated version of 电声学 测量传声器 第3部分:采用互易技术对实验室标准传声器的自由场校准的原级方法.
GB/T 20441.3-2010 — This section GB/T 20441 specifies the primary method for determining the free-field sensitivity level in order to establish in a free field conditions and reproducible Accurate measurement of sound pressure basis.
This section applies for laboratory standard microphones GB/T 20441.1 requirements. Principle calibration method applicable to other types of microphone. In particular, when fitted with the provisions of the adapter, in line with GB/T 20441.1 requirements microphone adapter can be removed, in accordance with this section calibration.
This section applies to laboratory technicians with high experience and special requirements.
Found what you need?
Document preview — GB/T 20441.3-2010
National Standard of the People's Republic of China
- ICS
- 17.140.50
- Classification
- A 59
- Replacing
- GB/T 6511-1986
Issued by: Standardization Administration of China
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Reference conditions
- 5 Free-field reciprocity calibration Principle
- 6 Factors Affecting the free-field sensitivity of
- 7 Calibration uncertainties
Foreword
GB/T 20441 "electric acoustic measurement microphone" is divided into seven sections.
--- Part 1. Laboratory standard microphones;
--- Part 2. Method using the original grade reciprocity technique of laboratory standard microphones sound pressure calibration;
--- Part 3. Method using the original grade reciprocity technique of laboratory standard microphones free-field calibration;
--- Part 4. Specifications for working standard microphones;
--- Part 5. working standard microphones calibration by comparison method;
--- Part 6. Determination of the frequency response of the electrostatic actuator;
--- Part 7. difference between laboratory standard microphones free-field sensitivity and sound pressure sensitivity between.
This section GB/T 20441 Part 3.
This section identical with IEC 61094-3:1995 "Electroacoustics Measurement microphones - Part 3. reciprocity technique laboratory standard the method of the original level of free-field microphone calibration "(in English).
For ease of use, this standard made the following editorial changes.
a) instead of as a decimal by decimal comma ",". ",";
b) Remove the IEC 61094-3:1995 Foreword;
c) increasing the mathematical meaning explanation letter underlined in Note 5.2.
This Part replaces GB/T 6511-1986 "adopted reciprocity technique phi23.77mm standard condenser microphone for free - field calibration of precision Encryption method. " this part of GB/T 6511-1986 The main differences are as follows.
In addition to the basic principles and techniques have a greater change in the content, structure, narrative and choreography;
a) increasing the foreword and directory;
b) the standard applies only to phi23.77mm of standard condenser microphones, the original scale method specified in this part apply to GB/T 20441 Laboratory standard microphones in Section 1 (including phi23.77mm standard microphone). Thus, in the text content in addition to the increased phi23.77mm microphone, the other part of laboratory standard microphones;
c) the content of the text by the 4 to 7. Increase the scope, normative references, reference conditions, the impact of free-field sensitivity Degree of uncertainty factors and calibration, replace the original standard calibration method and apparatus for calibration of absolute accuracy, etc.
content;
d) increase environmental impact Appendix C microphone sensitivity.
This part of the Annex A, Annex B, Annex C is informative appendix.
This part is proposed by the Ministry of Industry and Information Technology of the People's Republic of China.
This part of the National Standardization Technical Committee electro-acoustics (SAC/TC23) centralized.
This section is drafted. Nanjing University, Jiangsu Electronic Information Products Quality Supervision and Inspection Institute, China Testing Technology Research Institute.
1 Scope
This section GB/T 20441 specifies the primary method for determining the free-field sensitivity level in order to establish in a free field conditions and reproducible Accurate measurement of sound pressure basis.
This section applies for laboratory standard microphones GB/T 20441.1 requirements. Principle calibration method applicable to other types of microphone. In particular, when fitted with the provisions of the adapter, in line with GB/T 20441.1 requirements microphone adapter can be removed, in accordance with this section calibration.
This section applies to laboratory technicians with high experience and special requirements.
2 Normative references
The following documents contain provisions which, through reference GB/T 20441 in this section constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.
GB/T 17247.1-2000 acoustic attenuation of sound during propagation outdoors - Part 1. Calculation (eqv ISO 9613-1 atmospheric sound absorption.
1993)
GB/T 20441.1-2010 Electric Acoustic Measurement microphones - Part 1. Laboratory standard microphones (IEC 61094-1.
2000, IDT)
SJ/T 10444-1993 electroacoustic term (eqv IEC 60050 (801). 1984AcousticsandElectro-acoustics) Letter symbols used in Section 21972 of electronic technology.. IEC 60027-2 telecommunications and electronics IEC 61094-2:1992 Measurement microphones - Part 2. reciprocity technology laboratory calibration microphone sound pressure level of the original method ISO/IEC Guide.1995 Guide to the Expression of Uncertainty in Measurement (GUM)
3 Terms and Definitions
GB/T 20441.1-2010 and as defined in the following terms and definitions apply to this section.
Reciprocity microphone reciprocalmicrophone Linear passive microphone, its open forward and reverse transfer impedance (see IEC 60027-2. 1972 206) in magnitude relative and the like.
Free-field microphone sensitivity of the phase angle phaseangleoffree-fieldsensitivityofamicrophone for the sine plane traveling wave a given frequency, the sound incident direction and under given environmental conditions, the open circuit voltage of a predetermined sound pressure the phase angle between the microphone when not in the position of its center about the sound.
Note. in degrees or radians (° or rad).
Microphone acoustic center acousticcentreofamicrophone for transmitting the microphone, to a predetermined fixed frequency sinusoidal signal and the direction and distance of a point, the point about the concept of a small scale
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 17247.1-2000Acoustics. Attenuation of sound during propagation outdoors. Part 1: Calculation of the absorption of sound by the atmosphere
- GB/T 20441.1-2010Electroacoustics -- Measurement microphones -- Part 1: Specifications for laboratory standard microphones
GB/T 20441 · ISO 9613 · IEC 61094 · IEC 60050 · IEC 60027
How to Download GB/T 20441.3-2010
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 17247.1-2000 — Acoustics. Attenuation of sound during propagation outdoors. Part 1: Calculation of the absorption of sound by the atmosphere
GB/T 20441.1-2010 — Electroacoustics -- Measurement microphones -- Part 1: Specifications for laboratory standard microphones
GB/T 20441.2-2018 — Electroacoustics -- Measurement microphones -- Part 2: Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique
Secure payment via Stripe
Payments accepted
GB/T 20441.3-2010
$265.00