Scope

GB/T 20429-2024 is the English-translated version of 电热水器安装规范.

GB/T 20429-2024 lays down the requirements for installation accessories, the installation requirements, the installation operating procedure and the qualification of installers for electrical water heaters, and applies to the installation of the appliances covered by GB/T 4706.11 and GB/T 4706.12. It defines the user, the professional installer, the installing base, the installing frame and the installation activity itself, and lists the key accessories, from expansion bolts and the installing frame through mixing valve, shower head and hose, safety valve, temperature and pressure valve, discharge pipe, sealing gasket, non-return valve and pressure reducing valve to the expansion tank, that need the authorisation of the manufacturer. Clause 5 fixes how the position is chosen, the load-bearing capacity required of the installing base and of the installing frame relative to the mass of the appliance when full of water, the supply voltage range, the socket-outlet, the circuit capacity and the residual current protection, together with the rust-proofing and the free pressure relief outlet. Clause 6 follows the work from preparation and pre-installation checks through the installation itself to the post-installation checks, the trial run and the handover to the user.

Document preview — GB/T 20429-2024

National Standard of the People's Republic of China

ICS
97.100.10
Classification
Y 63
Replacing
GB 20429-2006

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Installation accessories for water heaters and their requirements
  • 4.1 Installation accessories and fittings
  • 4.2 Fasteners
  • 4.3 Water pipe connection
  • 5 Installation requirements for water heaters
  • 5.1 General requirements
  • 5.2 Installation position
  • 5.3 Installing base
  • 5.4 Electrical safety
  • 5.5 Mechanical strength
  • 5.6 Installation quality
  • 6 Installation operating procedure
  • 6.1 Preparation for installation
  • 6.2 Checks before installation
  • 6.3 Installation operations
  • 6.4 Checks after installation
  • 6.5 Trial run
  • 6.6 Handover
  • 7 Qualification requirements for installers

1 Scope, normative references and terms

1 The document lays down the requirements for the installation accessories, the installation requirements, the installation operating procedure and the qualification requirements for installers of electrical water heaters. It applies to the installation of the electrical water heaters covered by GB/T 4706.11 and GB/T 4706.12, referred to below as water heaters.

2 The normative references are GB/T 1002 on single-phase plugs and socket-outlets for household and similar purposes, GB/T 2099.1 on plugs and socket-outlets for household and similar purposes, GB/T 4706.11 on the particular requirements for instantaneous water heaters and GB/T 4706.12 on the particular requirements for storage water heaters.

3.1 user - individual, household or social body that uses the water heater product and receives the water heater service.

3.2 professional installer - person with a certain grounding and technical experience who has passed professional training and is authorised to complete the installation of a water heater in the correct manner.

3.3 installing base - load-bearing surface that supports and fixes the water heater. Note: usually a wall, floor or ceiling of the building.

3.4 installing frame - structural part that allows the water heater to be fixed securely to the installing base. Note: mounting brackets, hooks and hanging frames all count as installing frames.

3.5 installation for water heater - complete activity in which the professional installer, taking account of the actual installation environment, fixes the water heater in place and carries out the correct assembly, connection, commissioning and explanation so that its intended function is achieved.

4 Installation accessories for water heaters and their requirements

4.1 The accessories and fittings used to install the water heater are to meet the relevant national and industry standards and the installation instructions; where there is no national or industry standard, they are to meet the relevant standard of the water heater manufacturer. The following key accessories and fittings need the authorisation of the water heater manufacturer before use: expansion bolts; installing frame; mixing valve; shower head; shower hose; safety valve; temperature and pressure valve; discharge pipe; sealing gasket; non-return valve; pressure reducing valve; expansion tank.

4.2 The fixing or connecting bolts that carry load and resist shear during installation are to meet the relevant national standards and the installation instructions. Where the professional installer fits expansion bolts into concrete or a similar installing base, the diameter and depth of the hole are to be decided according to the material and the soundness of the base and a suitable size of expansion bolt chosen. The number of fixing points on the installing base is not to be fewer than that given in the installation instructions, so that the installation is stable, firm and reliable.

4.3 The pipework connecting the water heater to the tap water supply of the user is to have a certain strength and toughness, and for the safety of the user its resistance to high and low temperature, to water pressure and to corrosion is to reach the relevant national standards.

5 Installation requirements for water heaters

5.1 Installation is to be carried out by a professional installer. The choice of accessories and the installation are to meet the document and the general principles of the safety regulations, and to comply with the laws, regulations and standards issued by national and local government on electrical matters, building and environmental protection, as well as with the installation instructions of the product. The water heater to be installed is to have a mounting structure suited to its intended use and type and is to carry at least a safety certification mark.

5.2 The installation position is chosen after considering the conditions at the premises of the user: places where flammable gas may leak or where strongly corrosive gases may be present are to be avoided, as are places under the direct action of strong electric or magnetic fields; places subject to vibration should be avoided and the run between the water heater and the draw-off point should be kept short. Space is to be left for later repair, servicing, replacement, relocation and removal. The power connection is to be at a position where there is no risk of electric shock. The position is to take account of the power and water supply points so that water is not sprayed directly onto the water heater or the power connection; where the power connection is in a place liable to splashing, waterproofing measures are needed. The position is also to take account of free drainage so that drainage does not become obstructed. A class I water heater is to have an independent power connection with reliable earthing, failing which it is not to be installed. Unless the water heater is designed for outdoor use, the effects of direct sunlight, rain and wind are to be taken into account so that it works normally.

5.3 The installing base is to be firm and solid with sufficient load-bearing capacity, and its structure and material are to meet the relevant building requirements; its load-bearing capacity is to be not less than four times the total mass of the water heater when full of water. Where the strength of the base falls short, the user is to reinforce, support or damp it, or a dedicated installing frame is to be used, so that the normal operation of the water heater is not affected and no safety hazard arises.

5.4 The supply voltage of the water heater is to lie within 85 % to 110 % of its rated voltage. A water heater fitted with a plug is to use its own fixed socket-outlet, the structure of which matches the plug of the water heater and meets GB/T 2099.1 and GB/T 1002. Where the water heater has requirements concerning electromagnetic interference from the environment, such interference is to be avoided. The capacity of the supply circuit is to be greater than 1.5 times the rated current of the water heater. The water heater is to be connected through a residual current protective device, unless it already incorporates residual current protection beyond earthing protection.

5.5 The load-bearing capacity of the installing frame is to be not less than twice the total mass of the water heater when full of water. The connections between the installing base, the installing frame and the water heater are to be firm, stable and reliable so that the installed water heater does not slip off, overturn or fall. The installing frame and the fasteners are to be rust-proofed. On completion of the installation the pressure relief outlet of the water heater is to be open to the atmosphere.

5.6 The installation is not to have an adverse effect on the use of the product, and within one year of use of the water heater poor installation is not to affect its normal operation and performance.

6 Installation operating procedure and installer qualification

6.1 Before installation the installer is to bring the necessary installation tools and the calibrated inspection instruments, check the water heater and its accessories against the packing list for completeness and condition, and read the operating and installation instructions carefully so as to know the functions, method of use, installation requirements and installation method of the water heater to be fitted.

6.2 Before installation the installer is to check the power supply, the position of the socket-outlet, the water pressure, the drainage, the earthing, the available space and the load-bearing capacity of the installing base of the user, and find out whether the capacity of the meter, the wiring and the socket-outlet meets the requirements of the water heater; help the user choose the installation position; check with a phase tester or test pen that the live and neutral conductors of the supply to be used are correctly connected; and check the earthing of the supply by visual inspection and with an effective or dedicated earthing measuring device such as an earth resistance meter or phase tester, and judge whether it is sound. Where the requirements for installing the water heater cannot be met, the installer is to tell the user clearly and advise rectification; where rectification is not possible, the installer is to refuse to install.

6.3 During installation the accessories supplied with the appliance and the specified fittings are to be used, and the installer is not to substitute, omit or modify them at will; where a part has to be made up on site, it is to be made to the document and the installation instructions, to meet the relevant national standards and to be agreed by the manufacturer of the water heater before use. A suitable installation method is chosen according to the particular model and the installing frame is fixed firmly to the installing base; the work is not to damage the structures on which the safety of the building depends, and where necessary measures are to be taken so that neither the installer nor others are put at risk. On a closed water heater, where a non-return valve is added to the pipework, a means of safe pressure relief is to be provided between the non-return valve and the water heater. Where a safety valve is fitted, the discharge pipe is to be installed with a continuous downward run, open to the atmosphere, so that discharge is free and safe. When installation is complete the vessel of the water heater is filled until water flows continuously from the outlet.

6.4 After installation the quality of the work is checked, the main points being that the pipework is connected and routed sensibly with no leakage at the joints; that the mechanical connections are firm and reliable, the installing frame not slipping, working loose or bending when loaded in the most unfavourable position and direction; and that the electrical arrangement is safe and correct, the power connection of the water heater fitting closely.

6.5 The water heater is energised for a trial run and is to work normally. Parts of the enclosure where leakage current may appear are checked with a test pen, a multimeter or similar instrument; where leakage is found the appliance is stopped at once and the cause investigated, and where the fault is one of installation it is corrected before the trial run is repeated, until the water heater runs safely and normally. On a water heater with a residual current protective plug, a test is made to confirm that the plug works properly. The safety valve is operated by hand to confirm that the water heater can relieve pressure normally.

6.6 On completion the installer is to explain to the user the knowledge needed to use, maintain and service the water heater and to set out the rights and responsibilities of the user, and is to fill in the installation certificate carefully, which is confirmed by the user and signed and filed by the installer.

7 A person carrying out water heater installation work is to have passed professional training and obtained the corresponding certificate of qualification before taking up the work.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 8 pages — is available in the English PDF.

Referenced standards

Editions of GB/T 20429

EditionTitleRevisionStatus
GB/T 20429-2024Installation rule for electrical water heaterscurrent editionCurrent
GB 20429-2006Installation rule for electrical water heatersprevious editionIn force until 2026-08-01

This page sells the current edition, GB/T 20429-2024. Earlier editions are listed for reference only.

How to Buy GB/T 20429-2024

  1. 1Add to cart. Click the "Buy GB/T 20429-2024" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
8 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 20429-2024

$180.00

$155.00for partners