Valid

GB/T 19864.2-2013Stereomicroscopes -- Part 2: High performance microscopes (English PDF)

体视显微镜 第2部分:高性能体视显微镜

Preview PDF

This is a limited preview

Buy now to download the full PDF (7 pages)

Need quotation for your management?

Get a formal quotation for GB/T 19864.2-2013 in 30 minutes.

Issued by

Standardization Administration of China

Level / Type

National · Recommended

Issue date

December 17, 2013

Implementation date

July 15, 2014

Scope

GB/T 19864.2-2013 is the English-translated version of 体视显微镜 第2部分:高性能体视显微镜.

GB/T 19864.2-2013 — GB/T 19864 provisions of this part of the high-performance stereo microscope (hereinafter referred to as the microscope) of the basic parameters, requirements, test methods, Inspection rules, marking, packaging, and transportation and storage.

This section applies to continuous zoom stereo microscope. This section does not apply to the operating microscope.

Found what you need?

Document preview — GB/T 19864.2-2013

National Standard of the People's Republic of China

ICS
37.020
Classification
N 32
Replacing
GB/T 19864.2-2005

Issued by: Standardization Administration of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Basic parameters
  • 4 Eyepiece diopter adjustment range (diopter) -5 to 5

Foreword

GB/T 19864 "stereo microscope" is divided into two parts.

--- Part 1. universal stereo microscope;

--- Part 2. High performance stereo microscope.

This section GB/T Part of 219,864.

This section drafted in accordance with GB/T 1.1-2009 given rules.

This Part replaces GB/T 19864.2-2005 "stereomicroscopes - Part 2. High performance stereo microscope," and this section GB/T 19864.2-2005 main changes are as follows.

--- Chapter 1 increases the scope of application;

--- Remove phi23.2

Eyepiece and eyepiece Connecting dimensions;

--- Original standard 4.1.4 The title read. like object plane deviation in the center of the left and right center of the field;

--- Original standard 4.1.5 The title should read. about the optical system of the light beam direction deviations and its requirements increase to about convergence of 10 ', is divergent about 45';

--- Resolution lens center of the field increased to not less than 2500NA line pairs/mm;

--- Electrical safety performance of the pressure test requirements and methods for increasing the DC test.

This part of ISO 11884-2:2007 "minimum requirements for optics and photonics stereomicroscopes - Part 2. High performance reflects Microscopy Mirror "the degree of consistency is not equivalent. This part of ISO 11884-2:2007 The main differences are as follows.

--- Increasing the basic parameters of the instrument;

--- Press accustomed to "optical and mechanical properties" table format to the requirements of the provisions of narration;

--- In the "optical and mechanical properties" section adds about clear imaging, the basic requirements of the transmission mechanism, lighting, cleaning, etc.;

--- Increase the requirements for the appearance of the instrument;

--- Environmental testing provides only under conditions of transport packaging for environmental adaptability requirements.

This part is proposed by China Machinery Industry Federation.

This part of the National Standardization Technical Committee on Photonic and Optical Science (SAC/TC103) centralized.

This section is drafted. Shanghai Polytechnic University, Wuzhou Oka Optical Instrument Co., Ltd., Ningbo City, teaching Instrument Co., Ltd., Nanjing East Lee to Photoelectric Industrial Co., Ltd. Ningbo Sunny Instruments Co., Ltd. Ningbo Huaguang Precision Instrument Co., Ltd., Ningbo Yongxin Optics Company Limited Division Nanjing Jiangnan Yong new Optical Co., Ltd., Ningbo Cham Beijing Optical Instrument Co., Mike Audi Industrial Group Co., Ltd., Guangzhou, Guangdong was light Science Instrument Co., Ltd., Guiyang Xintian Optoelectronics Technology Co., Ltd., Chongqing Optical Instrument Co., Ltd.

1 Scope

GB/T 19864 provisions of this part of the high-performance stereo microscope (hereinafter referred to as the microscope) of the basic parameters, requirements, test methods, Inspection rules, marking, packaging, and transportation and storage.

This section applies to continuous zoom stereo microscope.

This section does not apply to the operating microscope.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

GB/T 2828.1 Sampling procedures for inspection - Part 1. by acceptance quality limit (AQL) retrieval batch inspection sampling plan GB/T 2829 periodic inspection Sampling procedures and tables (suitable for process stability test) GB 4793.1-2007 measurement, control and laboratory safety requirements for electrical equipment - Part 1. General requirements GB/T 9246 microscope eyepiece GB/T 13384 mechanical and electrical products packaging General technical conditions GB/T 19863 Test Method stereomicroscope GB/T 22056 and the eyepiece of the microscope objective signs GB/T 25480 Instrumentation transportation, storage and basic environmental conditions and test methods

3 Basic parameters

The basic parameters of the microscope should be consistent with Table 1.

Table 1

No. The basic parameters of the project 1 eyepiece and eyepiece connection size a/mm phi30 (30.5) F8 h8 ; Phi34 F8 h8 2 eyepiece magnification according to GB/T 9246 provisions choice

3 Binocular IPD adjustment range/mm minimum pupil distance of not more than 55, the maximum pupillary distance is not less than 75

4 Eyepiece diopter adjustment range (diopter) -5 to 5

a microscope according to the size of the model to select one size.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 19864.2-2013

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
7 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 19864.2-2013

$165.00