Valid

GB/T 19346-2003Amorphous and nanocrystalline alloys measurement methods -- Part 1: AC magnetic properties by the use of ring specimens (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (7 pages)

Need quotation for your management?

Get a formal quotation for GB/T 19346-2003 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People 's Republic of China

Level / Type

National · Recommended

Issue date

February 28, 2017

Implementation date

November 1, 2017

Scope

GB/T 19346-2003 (Amorphous and nanocrystalline alloys measurement methods -- Part 1: AC magnetic properties by the use of ring specimens) is available as an English-translated PDF.

GB/T 19346-2003 — This part of GB/T 19346 specifies the measurement method for the alternating magnetic properties of amorphous nanocrystalline alloy wound ring specimens.

This part is suitable for measuring a variety of transformer and inductance components and magnetic shielding with amorphous nanocrystalline soft magnetic alloy at 50Hz ~ 200kHz frequency range of the relative amplitude of the permeability, than the total loss, compared to the apparent power AC magnetic performance.

If there is a suitable calibration of the instrument, the frequency upper limit can be extended to 1MHz, but this time the reproduction should be appropriate to relax the requirements.

Found what you need?

Document preview — GB/T 19346-2003

National Standard of the People's Republic of China

ICS
77.040.99
Classification
H 21
Replacing
GB/T 19346-2003

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People 's Republic of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative reference documents
  • 3 Terms and definitions
  • 4 General rules
  • 4.1 Specimen

Foreword

This part is part 1 of GB/T 19346.

This part is drafted in accordance with the rules given in GB/T 1.1-2009.

This part of the replacement GB/T 19346-2003 "amorphous nanocrystalline soft magnetic alloy AC magnetic properties test method".

Compared with GB/T 19346-2003, the main contents are as follows.

--- name changed to "amorphous nanocrystalline alloy test method part 1. ring sample AC magnetic performance";

- Added terms and definitions (see Chapter 3);

- removed the voltammetric method of AC magnetic measurement (see Chapter 3 of the 2003 edition);

- Added general rules and modified sample requirements (see Chapter 4, Chapter 4 of the 2003 edition);

- Added technical requirements for digital peak ammeter, voltage digital-to-analog converters and power meters (see 5.4, 5.5, 5.16, 2003) Chapter 6);

- a method of measuring the permeability and magnetization curves by voltammetry (see Chapter 6);

- Removal of the voltammetric method (see 5.1 of 2003);

- increased method of measuring total loss with a power meter (see Chapter 7);

- modified and supplemented the digital sampling method and increased the measurement method of apparent power (see Chapter 8, Edition 5.2 of 2003);

- Increased requirements for reproducibility and uncertainty assessment of measurement results (see Chapter 9);

- Added the measurement report (see Chapter 10, Chapter 8 of the 2003 edition).

This part is made by China Iron and Steel Industry Association.

This part is headed by the National Steel Standardization Technical Committee (SAC/TC183).

This part of the drafting unit. China Steel Research Technology Group Co., Ltd., Metallurgical Industry Information Standards Institute, China Institute of Metrology.

1 Scope

This part of GB/T 19346 specifies the measurement method for the alternating magnetic properties of amorphous nanocrystalline alloy wound ring specimens.

This part is suitable for measuring a variety of transformer and inductance components and magnetic shielding with amorphous nanocrystalline soft magnetic alloy at 50Hz ~ 200kHz frequency range of the relative amplitude of the permeability, than the total loss, compared to the apparent power AC magnetic performance. If there is a suitable calibration of the instrument, the frequency upper limit can be extended to 1MHz, but this time the reproduction should be appropriate to relax the requirements.

2 Normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document.

GB/T 2900.1 Basic terminology for electrical terminology Electrotechnical terminology - Magnetic materials and components GB/T

3 Terms and definitions

GB/T 2900.1 and GB/T 9637 and the following terms and definitions apply to this document.

Than the total loss of specifictotalloss the total power absorbed by the unit mass of the homogeneous magnetized material in watts per kilogram (W/kg).

More specific than the apparent power Than apparent power the total apparent power delivered to the uniform magnetization of the unit mass in volts per kilogram (VA/kg).

4 General rules

4.1 Specimen

4.1.1 Measurement of AC magnetic properties of amorphous nanocrystalline soft magnetic alloys An annular specimen made of strip is used. If no special requirements, winding system the strip surface does not take insulation measures when the sample is taken.

4.1.2 Recommended specimen diameter of 35mm ± 2mm, the sample diameter and diameter ratio should be less than 1.25. If you need to use other feet the sample should be stated in the measurement report.

4.1.3 Specimens should be flat, burr, deformation and other defects.

4.1.4 The specimen shall be subjected to appropriate heat treatment prior to measurement. Specimen in the heat treatment process, should use non-ferromagnetic metal or ceramic lining support Hold the specimen inside the window to prevent the specimen from being deformed. The diameter of the lining should be slightly smaller than the diameter of the specimen and the height is comparable to that of the specimen. Sample heat treatment should be in a protective atmosphere to prevent surface oxidation.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.

How to Download GB/T 19346-2003

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
7 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 19346-2003

$174.00