GB/T 19212.5-2025Safety of transformers, reactors, power supply units and combinations thereof - Part 5: Particular requirements and tests for isolating transformers and power supply units incorporating isolating transformers for general applications (English PDF)
This is a limited preview
Buy now to download the full PDF (20 pages)
Need quotation for your management?
Get a formal quotation for GB/T 19212.5-2025 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Recommended
Issue date
February 28, 2025
Implementation date
September 1, 2025
Scope
GB/T 19212.5-2025 (Safety of transformers, reactors, power supply units and combinations thereof - Part 5: Particular requirements and tests for isolating transformers and power supply units incorporating isolating transformers for general applications) is available as an English-translated PDF.
GB/T 19212.5-2025 — This chapter of GB/T 19212.1-2023 is replaced by the following content. This document specifies the electrical, temperature and mechanical safety requirements and test requirements for isolating transformers and power supply units incorporating isolating transformers for general applications.
Transformers with electronic circuits are also included in this document. Unless otherwise specified, the term "transformer" below includes isolating transformers and power supply units incorporating isolating transformers for general applications.
For (linear) power supply units, this document applies. For switch mode power supply units, GB/T 19212.17 applies. This document applies to stationary or mobile, single-phase or multi-phase, air-cooled (natural or air-cooled), independent or associated dry-type transformers.
The windings can be encapsulated or non-encapsulated. The rated power supply voltage shall not exceed AC 1000 V, and the rated power supply frequency and internal operating frequency shall not exceed 500 Hz.
Rated output does not exceed. -- 25 kVA for single-phase transformers; -- 40 kVA for multiphase transformers. If the purchaser and the manufacturer agree otherwise, this document also applies to transformers with no restrictions on rated output.
NOTE 1.Transformers intended to supply power to distribution networks are not included in this scope. The no-load output voltage or rated output voltage exceeds 50 V AC or 120 V ripple- ......
Found what you need?
Document preview — GB/T 19212.5-2025
National Standard of the People's Republic of China
- ICS
- 29.180
Issued by: State Administration for Market Regulation
Contents
- Foreword...3
- Introduction...7
- 1 Scope...11
- 2 Normative references...12
- 3 Terms and definitions...13
- 4 General requirements...13
- 5 General notes on tests...13
- 6 Ratings...13
- 7 Classification...14
- 8 Marking and other information...14
- 9 Protection against electric shock...15
- 10 Change of input voltage setting value...15
- 11 Output voltage and output current under load...15
- 12 No-load output voltage...15
- 13 Short-circuit voltage...16
- 14 Heating...17
- 15 Short circuit and overload protection...17
- 16 Mechanical strength...17
- 17 Protection against harmful ingress of dust, solid foreign objects and moisture..17
- 18 Insulation resistance, dielectric strength and leakage current...17
- 19 Construction...17
- 20 Components...17
- 21 Internal wiring...17
- 22 Power supply connection and other external flexible cables or cords...17
- 23 Terminals for external conductors...18
- 24 Protective earthing device...18
- 25 Screws and connections...18
- 26 Creepage distances, clearances and distances through insulation...18
- 27 Resistance to heat, fire and tracking...18
- 28 Resistance to rusting...18
- Appendix...19
- References...20
Foreword
This document was drafted in accordance with the provisions of GB/T 1.1-2020
Directives for standardization - Part 1.Rules for the structure and drafting of
standardizing documents.
This document is Part 5 of GB/T 19212 Safety of transformers, reactors, power supply
units and combinations thereof 1). GB/T 19212 has been published in the following parts.
-- Part 1.General requirements and tests;
-- Part 2.Particular requirements and tests for separating transformers and power
supply units incorporating separating transformers for general applications;
-- Part 3.Particular requirements and tests for control transformers and power
supplies incorporating control transformers;
-- Part 4.Particular requirements and tests for ignition transformers for gas and oil
burners;
-- Part 5.Particular requirements and tests for isolating transformers and power
supply units incorporating isolating transformers for general applications;
-- Part 6.Particular requirements and test for transformer for shavers, power supply
units for shavers and shaver supply units;
-- Part 7.Particular requirements and test for safety isolating transformers and
power supply units incorporating safety isolating transformers;
-- Part 8.Particular requirements and tests for transformers and power supplies for
toys;
-- Part 9.Particular requirements and tests for transformers and power supply units
for bells and chimes;
-- Part 10.Particular requirements and tests for transformers and power supply
units for class III handlamps for tungsten filament lamps;
1) In this series of documents, some parts are under the title of "Safety of power transformers, power supplies,
reactors and similar products", some parts are under the title of "Safety of transformers, reactors, power supply
units and similar products for supply voltages up to 1100 V", and some parts are under the title of "Safety of
transformers, reactors, power supply units and combinations thereof". All future releases of this series of
documents will be published under the title of "Safety of transformers, reactors, power supply units and
combinations thereof".
-- Part 11.Particular requirements and tests for separating transformers with high
insulation level and separating transformers with output voltages exceeding
1000 V;
-- Part 13.Particular requirements and tests for constant voltage transformers and
power supply units for constant voltage;
-- Part 14.Particular requirements and tests for auto-transformers and power supply
units incorporating auto-transformers for general applications;
-- Part 15.Particular requirements and tests for variable transformers and power
supply units incorporating variable transformers;
-- Part 16.Particular requirements and tests for isolating transformers for the supply
of medical locations;
-- Part 17.Particular requirements and tests for switch mode power supply units
and transformers for switch mode power supply units;
-- Part 20.Particular requirements for perturbation attenuation transformers;
-- Part 21.Particular requirements and tests for small reactors;
-- Part 24.Particular requirements and test for transformers and power supply units
for construction sites;
-- Part 27.Particular requirements and tests for transformers and power supply
units all for saving energy and other purposes.
This document replaces GB/T 19212.5-2011 Safety of transformers, reactors, power
supply units and similar products for supply voltages up to 1100V - Part 5.Particular
requirements and tests for isolating transformers and power supply units incorporating
isolating transformers. Compared with GB/T 19212.5-2011, in addition to structural
adjustments and editorial changes, the main technical changes are as follows.
-- The scope has been changed and the rated power supply voltage of the applicable
scope has been changed from "1100 V" to "1000 V" (see Chapter 1; see Chapter
1 of the 2011 edition);
-- The rated power supply voltage has been changed (see 6.104; see 6.104 of the
2011 edition);
-- The graphic symbols have been changed, and a new symbol for the output
voltage of "linear power supply unit" has been added (see Chapter 8; see Chapter
8 of the 2011 edition);
Safety of transformers, reactors, power supply units and
combinations thereof - Part 5.Particular requirements and
tests for isolating transformers and power supply units
incorporating isolating transformers for general applications
1 Scope
This chapter of GB/T 19212.1-2023 is replaced by the following content.
This document specifies the electrical, temperature and mechanical safety requirements
and test requirements for isolating transformers and power supply units incorporating
isolating transformers for general applications. Transformers with electronic circuits are
also included in this document.
Unless otherwise specified, the term "transformer" below includes isolating
transformers and power supply units incorporating isolating transformers for general
applications.
For (linear) power supply units, this document applies. For switch mode power supply
units, GB/T 19212.17 applies.
This document applies to stationary or mobile, single-phase or multi-phase, air-cooled
(natural or air-cooled), independent or associated dry-type transformers. The windings
can be encapsulated or non-encapsulated.
The rated power supply voltage shall not exceed AC 1000 V, and the rated power supply
frequency and internal operating frequency shall not exceed 500 Hz.
Rated output does not exceed.
-- 25 kVA for single-phase transformers;
-- 40 kVA for multiphase transformers.
If the purchaser and the manufacturer agree otherwise, this document also applies to
transformers with no restrictions on rated output.
NOTE 1.Transformers intended to supply power to distribution networks are not included in this scope.
The no-load output voltage or rated output voltage exceeds 50 V AC or 120 V ripple-
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.
Referenced standards
Cited by
- GB/T 4706.103-2024Safety of household and similar electrical appliances - Part 103: Particular requirements for electric fishing machines
- GB/T 4706.18-2024Safety of household and similar electrical appliances - Part 18: Particular requirements for battery chargers
- GB/T 20674.2-2020Plastic pipes and fittings Polyethylene system welding equipment - Part 2: Electrofusion connection
- GB/T 19212.17-2019Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V -- Part 17: Particular requirements and tests for switch mode power supply units and transformers for switch mode power supply units
How to Download GB/T 19212.5-2025
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 19212.1-2023 — Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests
GB/T 19212.11-2020 — Safety of transformers, reactors, power supply units and combinations thereof - Part 11: Particular requirements and tests for separating transformers with high insulation level and separating transformers with output voltages exceeding 1 000 V
GB/T 19212.13-2019 — Safety of transformers, reactors, power supply units and combination thereof -- Part 13: Particular requirements and tests for constant voltage transformers and power supply units for constant voltage
Secure payment via Stripe
Payments accepted
GB/T 19212.5-2025
$250.00