GB/T 18989-2013Radionuclide imaging device -- Characteristics and test conditions -- Gamma cameras (English PDF)
放射性核素成像设备 性能和试验规则 伽玛照相机
This is a limited preview
Buy now to download the full PDF (35 pages)
Need quotation for your management?
Get a formal quotation for GB/T 18989-2013 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
December 17, 2013
Implementation date
August 1, 2014
Scope
GB/T 18989-2013 is the English-translated version of 放射性核素成像设备 性能和试验规则 伽玛照相机.
GB/T 18989-2013 — This standard specifies the relevant definitions, test methods and product random file gamma camera. This standard applies to Anger type gamma camera, the apparatus comprises a collimator and detector shielding radiation detector assembly, as well as record and a display device.
Found what you need?
Document preview — GB/T 18989-2013
National Standard of the People's Republic of China
- ICS
- 11.040.50
- Classification
- C 43
- Replacing
- GB/T 18989-2003
Issued by: Standardization Administration of China
Contents
- Introduction
- Introduction
- 1 Scope
- 2 Terms and definitions
- Test Method 3
- 4 Product random file
- Determination of Annex A (informative) source activity of
- Annex B (informative) Performance Parameters Symbol Index
- Annex C (informative) This standard reg number and IEC 60789:1992 reg control number
- Annex D (informative) This standard and IEC 60789:1992 technical differences and their reasons
- Appendix E (Informative Appendix) NEMANU1 publication gamma camera probe test
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard replaces GB/T 18989-2003 "Radionuclide imaging device - Characteristics and test gamma camera", and GB/T 18989-2003, compared the main technical changes are as follows.
--- Remove the GB/T 18989-2003 body NEMA relevant content;
--- Increase the informative Appendix E, appendix uses a NEMA Standards Publication NU1-2007 "Gamma Camera Performance Test" Chapter 2, Section 3 of the content;
--- Increased introduction.
This standard uses redrafted law revision adopted IEC 60789:1992 "Radionuclide imaging device - Characteristics and test gamma Camera ", according to the standard rules of the preparation of this standard, the following editorial changes made. Added informative and informative Appendix B attached Record E.
This standard remains GB/T 18989-2003 modify using IEC 60789:1992; This standard and IEC 60789:1992 Code of reg CrossRef See Appendix C; this standard and IEC 60789:1992 technical differences between their causes, see Appendix D.
Please note that some of the content of this document may involve patents. The standard release mechanism does not assume the responsibility to identify these patents.
This standard was proposed by the State Food and Drug Administration.
This standard by the National Standardization Technical Committee appliances medical radiotherapy, nuclear medicine and radiation dosimetry equipment Standardization Technical Committee Will (SAC/TC10/SC3) centralized.
This standard was drafted. Beijing Medical Device Testing, Beijing Hamamatsu Photonics Co., Ltd., Siemens (China) Co., Ltd., Tong Electrical (China) Co., Ltd.
Introduction
GB/T 18989-2003 modify using IEC 60789:1992. Currently, the major manufacturers of radionuclide imaging device production Venues are located in the United States, the parameters of its report, the data processing software, test phantoms are the National Electrical Manufacturers Association NEMA standards for for the design basis, but also manufacturers use IEC standard. In order to facilitate the government, enterprises and medical institutions understand and use these products IEC and two series NEMA standard content, this revision will NEMA Standards Publication NU1-2007 "Gamma Camera Performance Test" on Chapter 2, Chapter 3 of the introduction of this standard, as an information Appendix E.
Since the IEC and NEMA standards there are some differences in testing requirements, test methods, the use of motifs, test conditions, test Position, the calculation method is different, so I can not compare with each other between the two standard test items and complete references recommend two standard user the method of any one species, not cross-use.
Radionuclide imaging devices - Characteristics and test Gamma Camera
1 Scope
This standard specifies the relevant definitions, test methods and product random file gamma camera.
This standard applies to Anger type gamma camera, the apparatus comprises a collimator and detector shielding radiation detector assembly, as well as record and a display device.
2 Terms and definitions
The following terms and definitions apply to this document.
Sources radioactivesource 2.1.1 Sources radioactivesource Activity and specific activity are predetermined level above a certain amount of radioactive material.
2.1.2
Point Source Approximate dimensions in three directions are radioactive delta function.
2.1.3
Line source Size in both directions delta approximate linear function of radioactive sources in the third direction of activity is uniform.
2.1.4
Activity
At a time, in a certain amount of radionuclide specific levels of radioactivity on quantified. Activity divided by the dN dt quotient OK, where dN is the expected value at the time the number of nuclei decay within a certain level interval dt, see equation (1).
A = dN/dt (1)
The special unit of activity Bq [Harrell] (Bq), 1Bq decay per second is equal to one. Activity unit s-1 can also be represented.
2.1.5
Attenuation when radiation passes through matter, interacting with a variety of substances to cause a decrease in some amount of radiation. For example, the amount of radiation may be a particle through the amount of energy flux density or density.
Note. does not include the amount of radiation attenuation due to different geometric distance from the radiation source caused decreases.
Pulse amplitude analyzer window (called the analyzer window) pulseamplitudeanalyserwindow Pulse amplitude analyzer input signal amplitude range, in this range, an output signal analyzer.
Gamma Camera
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 35 pages — is available in the English PDF.
Referenced standards
Cited by
- YY/T 1546-2017Testing method for SPECT imaging based on CT-attenuation correction
- YY/T 1408-2016Performance characteristics and test methods of imaging system of single photon emission and X-ray computed tomograph
- GB/T 18988.3-2013Radionuclide imaging device -- Characteristics and test conditions -- Part 3: Gamma camera based-whole body imaging systems
How to Download GB/T 18989-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 47915.2-2026 — Chemical analysis methods for rare earth zirconium-based compounds — Part 2: Determination of the total content of zirconium oxide and hafnium oxide — Mandelic acid gravimetric method
GB/T 47813-2026 — General specification for the tether launching and retrieving mechanism of tethered aerostats
GB/T 33679-2026 — Storage conditions for combustion agents and cooling agents used in weather modification
Secure payment via Stripe
Payments accepted
GB/T 18989-2013
$885.00