GB/T 18802.31-2021Low-voltage surge protective devices—Part 31: Surge protective devices connected to photovoltaic installations—Requirements and test methods (English PDF)
低压电涌保护器 第31部分:用于光伏系统的电涌保护器 性能要求和试验方法
Also coversGBT18802.31-2021
This is a limited preview
Buy now to download the full PDF
Need quotation for your management?
Get a formal quotation for GB/T 18802.31-2021 in 30 minutes.
Issued by
State Administration for Market Regulation; Standardization Administration of China
Level / Type
National · Recommended
Issue date
March 9, 2021
Implementation date
October 1, 2021
Scope
GB/T 18802.31-2021 is the English-translated version of 低压电涌保护器 第31部分:用于光伏系统的电涌保护器 性能要求和试验方法.
GB/T 18802.31-2021 — This part specifies the performance requirements and test methods for SPDs installed on the DC side of a photovoltaic system. This type of SPD is used to reduce the impact of lightning induction or direct lightning on the DC side of photovoltaic power generation equipment. These appliances will be connected to the DC power circuit of a photovoltaic power generation equipment which has a rated voltage not exceeding 1500 V. This part considers the following characteristics of photovoltaic power generation equipment. - Characteristics similar to current sources; - The nominal current depends on the light intensity; - The short-circuit current is almost equal to the nominal current; - Output various sizes of voltage, current and power in series and/or parallel combination, from several hundred watts (civil facilities) to several megawatts (photovoltaic field). The very special electrical parameters on the DC side of the photovoltaic equipment place special test requirements on the SPD. SPD with special series impedance between separate input and output terminals (so-called two-port SPD in EN 61643-11) are not currently fully covered by the performance requirements of this standard, which require additional consideration. Note. For SPD used in photovoltaic systems, for power efficiency considerations, special series impedances are typically not included between the input and output terminals. SPD conforming to this standard are only designed to be installed on the DC side of a photovoltaic generator. Regardless of photovoltaic equipment containing battery packs and other DC equipment, it requires additional requirements and tests for SPDs used in this equipment. For SPD where the manufacturer states that the overload characteristic is short- circuit mode, special measures must be required to prevent the DC arc that may be generated during the maintenance and replacement of such SPD from jeopardizing the operator.
Found what you need?
Document preview — GB/T 18802.31-2021
National Standard of the People's Republic of China
- ICS
- 29.240.10
- Classification
- K30
Issued by: State Administration for Market Regulation; Standardization Administration of China
Contents
- Foreword...6
- 1 Scope...8
- 2 Normative references...9
- 3 Terms, definitions and abbreviations...10
- 3.1 Terms and definitions...10
- 3.2 Abbreviations...19
- 4 Conditions of use...20
- 4.1 Voltage...20
- 4.2 Air pressure and altitude...20
- 4.3 Temperature...20
- 4.4 Humidity...21
- 5 Classification...21
- 5.1 SPD's design type...21
- 5.2 Class I and class II tests for class 1 and class 2 SPD...21
- 5.3 Location of use...21
- 5.3.1 Indoors...21
- 5.3.2 Outdoor...22
- 5.4 Accessibility...22
- 5.4.1 Easily accessible...22
- 5.4.2 Not easily accessible...22
- 5.5 SPD disconnector (including over-current protection)...22
- 5.6 Degree of protection of enclosure...23
- 5.7 Temperature and humidity range...23
- 5.8 Multipole SPD...23
- 5.9 Connection structure...23
- 5.10 SPD's overload characteristic mode...25
- 6 Technical requirements...25
- 6.1 General requirements...25
- 6.1.1 General...25
- 6.1.2 Identification...25
- 6.1.3 Markings...28
- 6.2 Electrical performance requirements...28
- 6.2.1 Protection against direct contact...28
- 6.2.2 Residual current IPE...29
- 6.2.3 Voltage protection level Up...29
- 6.2.5 Disconnector and status indicator...29
- 6.2.6 Insulation resistance...31
- 6.2.7 Dielectric strength...31
- 6.2.8 Continuous operating current (ICPV)...31
- 6.2.9 Total discharge current ITotal (for multipole SPD)...31
- 6.3 Mechanical performance requirements...31
- 6.3.1 Installation...31
- 6.3.2 Screws, current-carrying parts and connections...31
- 6.3.3 External connection...32
- 6.3.4 Electric clearance and creepage distance...32
- 6.3.5 Mechanical strength...32
- 6.4 Environmental and material requirements...32
- 6.4.1 General...32
- 6.4.2 Life test under damp heat conditions...33
- 6.4.3 Electromagnetic compatibility...33
- 6.5 Additional requirements for special SPD designs...33
- 6.5.1 One-port SPD with separate input and output terminals...33
- 6.5.2 Environmental test of outdoor SPD...34
- 6.5.3 SPD with separately-isolated circuit...34
- 6.6 Additional requirements that the manufacturer may claim...34
- 6.6.1 Maximum discharge current Imax...34
- 7 Type test...34
- 7.1 General...34
- 7.2 General test procedures...35
- 7.2.1 General...35
- 7.2.2 Impulse discharge current for class I additional load test...39
Foreword
The structure and name of the "Low-voltage surge protective devices (SPD)"
series of standards are as follows.
- GB 18802.1 Low-voltage surge protective devices - Part 1.Surge protective
devices connected to low-voltage power distribution systems -
Requirements and tests;
- GB/T 18802.12 Low-voltage surge protective devices - Part 12.Surge
protective devices connected to low-voltage power distribution systems -
Selection and application principles;
- GB/T 18802.21 Low-voltage surge protective devices - Part 21.Surge
protective devices connected to telecommunications and signaling
networks - Performance requirements and testing methods;
- GB/T 18802.22 Low-voltage surge protective devices - Part 22.Surge
protective devices connected to telecommunications and signaling
networks - Selection and application principles;
- GB/T 18802.31 Low-voltage surge protective devices - Surge protective
devices for specific application including d.c. - Part 31.Requirements and
tests for SPDs in photovoltaic applications;
- GB/T 18802.311 Components for low-voltage surge protective - Part 311.
Specification for gas discharge tubes (GDT);
- GB/T 18802.321 Components for low-voltage surge protective devices -
Part 321.Specifications for avalanche breakdown diode (ABD);
- GB/T 18802.331 Components for low-voltage surge protective devices -
Part 331.Specification for metal oxide varistors (MOV);
- GB/T 18802.341 Components for low-voltage surge protective devices -
Part 341.Specification for thyristor surge suppressors (TSS).
This part was drafted in accordance with the rules given in GB/T 1.1-2009.
This part was proposed by China Electrical Equipment Industry Association.
This part shall under the jurisdiction of the National Lightning Protection
Standardization Technical Committee (SAC/TC 81).
Responsible drafting organizations of this part. Shanghai Lightning Protection
Center, Xi'an High Voltage Electric Apparatus Research Institute Co., Ltd.
Low-voltage surge protective devices - Surge
protective devices for specific application including
d.c. - Part 31.Requirements and tests for
SPDs in photovoltaic applications
1 Scope
This part specifies the performance requirements and test methods for SPDs
installed on the DC side of a photovoltaic system. This type of SPD is used to
reduce the impact of lightning induction or direct lightning on the DC side of
photovoltaic power generation equipment. These appliances will be connected
to the DC power circuit of a photovoltaic power generation equipment which
has a rated voltage not exceeding 1500 V.
This part considers the following characteristics of photovoltaic power
generation equipment.
- Characteristics similar to current sources;
- The nominal current depends on the light intensity;
- The short-circuit current is almost equal to the nominal current;
- Output various sizes of voltage, current and power in series and/or parallel
combination, from several hundred watts (civil facilities) to several
megawatts (photovoltaic field).
The very special electrical parameters on the DC side of the photovoltaic
equipment place special test requirements on the SPD.
SPD with special series impedance between separate input and output
terminals (so-called two-port SPD in EN 61643-11) are not currently fully
covered by the performance requirements of this standard, which require
additional consideration.
Note. For SPD used in photovoltaic systems, for power efficiency
considerations, special series impedances are typically not included between
the input and output terminals.
SPD conforming to this standard are only designed to be installed on the DC
side of a photovoltaic generator. Regardless of photovoltaic equipment
containing battery packs and other DC equipment, it requires additional
requirements and tests for SPDs used in this equipment.
For SPD where the manufacturer states that the overload characteristic is short-
circuit mode, special measures must be required to prevent the DC arc that
may be generated during the maintenance and replacement of such SPD from
jeopardizing the operator.
2 Normative references
The following documents are essential to the application of this document. For
the dated documents, only the versions with the dates indicated are applicable
to this document; for the undated documents, only the latest version (including
all the amendments) are applicable to this standard.
GB/T 2900.83-2008 Electrotechnical terminology - Electrical and magnetic
devices (IEC 60050-151.2001, IDT)
HD 588.1 S1.1991 High-voltage test techniques - Part 1.General definitions
and test requirements, IEC 60060-1.1989 + corrigendum Mar, IEC 60060-
1.1989 + Errata 1990-03
EN 50521 Connectors for photovoltaic systems Safety requirements and
tests
EN 60068-2-78 Environmental testing - Part 2-78.Tests Test Cab. Damp
heat, steady state, IEC 60068-2-78
EN 60529 Degrees of protection provided by enclosures (IP Code), IEC
EN 60664-1.2007 Insulation coordination for equipment within low-voltage
systems - Part 1.Principles, requirements and tests, IEC 60664-1.2007)
EN 61000-6-1 Electromagnetic compatibility (EMC) - Part 6-1.Generic
standards Immunity for residential, commercial and light-industrial
environments, IEC 61000-6-1
EN 61000-6-3 Electromagnetic compatibility (EMC) - Part 6-3.Generic
standards Emission standard for residential, commercial and light-industrial
environments, IEC 61000 -6-3
EN 61180-1 High-voltage test techniques for low-voltage equipment - Part 1.
Definitions, test and procedure requirements, IEC 61180-1
EN 61643-11.2012 Low-voltage surge protective devices - Part 11.Surge
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
GB/T 2900.83-2008 · IEC 60050 · IEC 60060
Cited by
How to Download GB/T 18802.31-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 18802.11-2020 — Low-voltage surge protective devices (SPD) - Part 11: Surge protective devices connected to low-voltage power systems - Requirements and test methods
GB/T 18802.22-2019 — Low-voltage surge protective devices -- Part 22: Surge protective devices connected to telecommunications and signalling networks -- Selection and application principles
GB/T 18802.351-2019 — Components for low-voltage surge protective devices -- Part 351: Performance requirements and test methods for telecommunications and signalling network surge isolation transformers (SIT)
Secure payment via Stripe
Payments accepted
GB/T 18802.31-2021
$780.00