GB/T 18802.31-2021Low-voltage surge protective devices—Part 31: Surge protective devices connected to photovoltaic installations—Requirements and test methods (English PDF)

低压电涌保护器 第31部分:用于光伏系统的电涌保护器 性能要求和试验方法

Preview PDF

Also coversGBT18802.31-2021

This is a limited preview

Buy now to download the full PDF

Need quotation for your management?

Get a formal quotation for GB/T 18802.31-2021 in 30 minutes.

Issued by

State Administration for Market Regulation; Standardization Administration of China

Level / Type

National · Recommended

Issue date

March 9, 2021

Implementation date

October 1, 2021

Scope

GB/T 18802.31-2021 is the English-translated version of 低压电涌保护器 第31部分:用于光伏系统的电涌保护器 性能要求和试验方法.

GB/T 18802.31-2021 — This part specifies the performance requirements and test methods for SPDs installed on the DC side of a photovoltaic system. This type of SPD is used to reduce the impact of lightning induction or direct lightning on the DC side of photovoltaic power generation equipment. These appliances will be connected to the DC power circuit of a photovoltaic power generation equipment which has a rated voltage not exceeding 1500 V. This part considers the following characteristics of photovoltaic power generation equipment. - Characteristics similar to current sources; - The nominal current depends on the light intensity; - The short-circuit current is almost equal to the nominal current; - Output various sizes of voltage, current and power in series and/or parallel combination, from several hundred watts (civil facilities) to several megawatts (photovoltaic field). The very special electrical parameters on the DC side of the photovoltaic equipment place special test requirements on the SPD. SPD with special series impedance between separate input and output terminals (so-called two-port SPD in EN 61643-11) are not currently fully covered by the performance requirements of this standard, which require additional consideration. Note. For SPD used in photovoltaic systems, for power efficiency considerations, special series impedances are typically not included between the input and output terminals. SPD conforming to this standard are only designed to be installed on the DC side of a photovoltaic generator. Regardless of photovoltaic equipment containing battery packs and other DC equipment, it requires additional requirements and tests for SPDs used in this equipment. For SPD where the manufacturer states that the overload characteristic is short- circuit mode, special measures must be required to prevent the DC arc that may be generated during the maintenance and replacement of such SPD from jeopardizing the operator.

Found what you need?

Document preview — GB/T 18802.31-2021

National Standard of the People's Republic of China

ICS
29.240.10
Classification
K30

Issued by: State Administration for Market Regulation; Standardization Administration of China

Contents

  • Foreword...6
  • 1 Scope...8
  • 2 Normative references...9
  • 3 Terms, definitions and abbreviations...10
  • 3.1 Terms and definitions...10
  • 3.2 Abbreviations...19
  • 4 Conditions of use...20
  • 4.1 Voltage...20
  • 4.2 Air pressure and altitude...20
  • 4.3 Temperature...20
  • 4.4 Humidity...21
  • 5 Classification...21
  • 5.1 SPD's design type...21
  • 5.2 Class I and class II tests for class 1 and class 2 SPD...21
  • 5.3 Location of use...21
  • 5.3.1 Indoors...21
  • 5.3.2 Outdoor...22
  • 5.4 Accessibility...22
  • 5.4.1 Easily accessible...22
  • 5.4.2 Not easily accessible...22
  • 5.5 SPD disconnector (including over-current protection)...22
  • 5.6 Degree of protection of enclosure...23
  • 5.7 Temperature and humidity range...23
  • 5.8 Multipole SPD...23
  • 5.9 Connection structure...23
  • 5.10 SPD's overload characteristic mode...25
  • 6 Technical requirements...25
  • 6.1 General requirements...25
  • 6.1.1 General...25
  • 6.1.2 Identification...25
  • 6.1.3 Markings...28
  • 6.2 Electrical performance requirements...28
  • 6.2.1 Protection against direct contact...28
  • 6.2.2 Residual current IPE...29
  • 6.2.3 Voltage protection level Up...29
  • 6.2.5 Disconnector and status indicator...29
  • 6.2.6 Insulation resistance...31
  • 6.2.7 Dielectric strength...31
  • 6.2.8 Continuous operating current (ICPV)...31
  • 6.2.9 Total discharge current ITotal (for multipole SPD)...31
  • 6.3 Mechanical performance requirements...31
  • 6.3.1 Installation...31
  • 6.3.2 Screws, current-carrying parts and connections...31
  • 6.3.3 External connection...32
  • 6.3.4 Electric clearance and creepage distance...32
  • 6.3.5 Mechanical strength...32
  • 6.4 Environmental and material requirements...32
  • 6.4.1 General...32
  • 6.4.2 Life test under damp heat conditions...33
  • 6.4.3 Electromagnetic compatibility...33
  • 6.5 Additional requirements for special SPD designs...33
  • 6.5.1 One-port SPD with separate input and output terminals...33
  • 6.5.2 Environmental test of outdoor SPD...34
  • 6.5.3 SPD with separately-isolated circuit...34
  • 6.6 Additional requirements that the manufacturer may claim...34
  • 6.6.1 Maximum discharge current Imax...34
  • 7 Type test...34
  • 7.1 General...34
  • 7.2 General test procedures...35
  • 7.2.1 General...35
  • 7.2.2 Impulse discharge current for class I additional load test...39

Foreword

The structure and name of the "Low-voltage surge protective devices (SPD)"

series of standards are as follows.

- GB 18802.1 Low-voltage surge protective devices - Part 1.Surge protective

devices connected to low-voltage power distribution systems -

Requirements and tests;

- GB/T 18802.12 Low-voltage surge protective devices - Part 12.Surge

protective devices connected to low-voltage power distribution systems -

Selection and application principles;

- GB/T 18802.21 Low-voltage surge protective devices - Part 21.Surge

protective devices connected to telecommunications and signaling

networks - Performance requirements and testing methods;

- GB/T 18802.22 Low-voltage surge protective devices - Part 22.Surge

protective devices connected to telecommunications and signaling

networks - Selection and application principles;

- GB/T 18802.31 Low-voltage surge protective devices - Surge protective

devices for specific application including d.c. - Part 31.Requirements and

tests for SPDs in photovoltaic applications;

- GB/T 18802.311 Components for low-voltage surge protective - Part 311.

Specification for gas discharge tubes (GDT);

- GB/T 18802.321 Components for low-voltage surge protective devices -

Part 321.Specifications for avalanche breakdown diode (ABD);

- GB/T 18802.331 Components for low-voltage surge protective devices -

Part 331.Specification for metal oxide varistors (MOV);

- GB/T 18802.341 Components for low-voltage surge protective devices -

Part 341.Specification for thyristor surge suppressors (TSS).

This part was drafted in accordance with the rules given in GB/T 1.1-2009.

This part was proposed by China Electrical Equipment Industry Association.

This part shall under the jurisdiction of the National Lightning Protection

Standardization Technical Committee (SAC/TC 81).

Responsible drafting organizations of this part. Shanghai Lightning Protection

Center, Xi'an High Voltage Electric Apparatus Research Institute Co., Ltd.

Low-voltage surge protective devices - Surge

protective devices for specific application including

d.c. - Part 31.Requirements and tests for

SPDs in photovoltaic applications

1 Scope

This part specifies the performance requirements and test methods for SPDs

installed on the DC side of a photovoltaic system. This type of SPD is used to

reduce the impact of lightning induction or direct lightning on the DC side of

photovoltaic power generation equipment. These appliances will be connected

to the DC power circuit of a photovoltaic power generation equipment which

has a rated voltage not exceeding 1500 V.

This part considers the following characteristics of photovoltaic power

generation equipment.

- Characteristics similar to current sources;

- The nominal current depends on the light intensity;

- The short-circuit current is almost equal to the nominal current;

- Output various sizes of voltage, current and power in series and/or parallel

combination, from several hundred watts (civil facilities) to several

megawatts (photovoltaic field).

The very special electrical parameters on the DC side of the photovoltaic

equipment place special test requirements on the SPD.

SPD with special series impedance between separate input and output

terminals (so-called two-port SPD in EN 61643-11) are not currently fully

covered by the performance requirements of this standard, which require

additional consideration.

Note. For SPD used in photovoltaic systems, for power efficiency

considerations, special series impedances are typically not included between

the input and output terminals.

SPD conforming to this standard are only designed to be installed on the DC

side of a photovoltaic generator. Regardless of photovoltaic equipment

containing battery packs and other DC equipment, it requires additional

requirements and tests for SPDs used in this equipment.

For SPD where the manufacturer states that the overload characteristic is short-

circuit mode, special measures must be required to prevent the DC arc that

may be generated during the maintenance and replacement of such SPD from

jeopardizing the operator.

2 Normative references

The following documents are essential to the application of this document. For

the dated documents, only the versions with the dates indicated are applicable

to this document; for the undated documents, only the latest version (including

all the amendments) are applicable to this standard.

GB/T 2900.83-2008 Electrotechnical terminology - Electrical and magnetic

devices (IEC 60050-151.2001, IDT)

HD 588.1 S1.1991 High-voltage test techniques - Part 1.General definitions

and test requirements, IEC 60060-1.1989 + corrigendum Mar, IEC 60060-

1.1989 + Errata 1990-03

EN 50521 Connectors for photovoltaic systems Safety requirements and

tests

EN 60068-2-78 Environmental testing - Part 2-78.Tests Test Cab. Damp

heat, steady state, IEC 60068-2-78

EN 60529 Degrees of protection provided by enclosures (IP Code), IEC

EN 60664-1.2007 Insulation coordination for equipment within low-voltage

systems - Part 1.Principles, requirements and tests, IEC 60664-1.2007)

EN 61000-6-1 Electromagnetic compatibility (EMC) - Part 6-1.Generic

standards Immunity for residential, commercial and light-industrial

environments, IEC 61000-6-1

EN 61000-6-3 Electromagnetic compatibility (EMC) - Part 6-3.Generic

standards Emission standard for residential, commercial and light-industrial

environments, IEC 61000 -6-3

EN 61180-1 High-voltage test techniques for low-voltage equipment - Part 1.

Definitions, test and procedure requirements, IEC 61180-1

EN 61643-11.2012 Low-voltage surge protective devices - Part 11.Surge

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

Referenced standards

How to Download GB/T 18802.31-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 18802.31-2021

$780.00