GB/T 17949.1-2000Guide for measuring earth resistivity, ground impedance, and earth surface potentials of a ground system. Part 1: Normal measurements (English PDF)
接地系统的土壤电阻率、接地阻抗和地面电位测量导则 第1部分:常规测量
This is a limited preview
Buy now to download the full PDF (24 pages)
Need quotation for your management?
Get a formal quotation for GB/T 17949.1-2000 in 30 minutes.
Issued by
State Quality and Technical Supervision
Level / Type
National · Recommended
Issue date
January 3, 2000
Implementation date
August 1, 2000
Scope
GB/T 17949.1-2000 is the English-translated version of 接地系统的土壤电阻率、接地阻抗和地面电位测量导则 第1部分:常规测量.
GB/T 17949.1-2000 — This standard specifies test methods include: (1) measurement from small ground rod, ground plate to the plant grounding system, and other large-scale ground pole ground resistance and ground impedance, (2) measuring the ground potential, including measuring step voltage, the contact voltage and equipotential lines, (3) to improve the engineering design, proportional model test method, the test chamber predicted ground resistance and ground potential gradient, (4) measurement of soil resistivity.
Listed in this standard test method is limited to the use of direct current, DC current cyclical commutation, sinusoidal AC currents and inrush current (used to measure the impact of grounding impedance). The guidelines do not include all possible means of testing and test methods.
Found what you need?
Document preview — GB/T 17949.1-2000
National Standard of the People's Republic of China
- ICS
- 29.020
- Classification
- K 60
Issued by: State Quality and Technical Supervision
Contents
- What this standard covers1
- Document data2
What this standard covers
This standard specifies test methods include: (1) measurement from small ground rod, ground plate to the plant grounding system, and other large-scale ground pole ground resistance and ground impedance, (2) measuring the ground potential, including measuring step voltage, the contact voltage and equipotential lines, (3) to improve the engineering design, proportional model test method, the test chamber predicted ground resistance and ground potential gradient, (4) measurement of soil resistivity. Listed in this standard test method is limited to the use of direct current, DC current cyclical commutation, sinusoidal AC currents and inrush current (used to measure the impact of grounding impedance). The guidelines do not include all possible means of testing and test methods. Because of the many variables in the test, the test is difficult to achieve highly accurate and therefore the most appropriate use of existing test methods carefully do the test, but also a thorough understanding of the cause of the error.
Document data
International classification (ICS): 29.020.
Chinese classification (CCS): K60.
Estimated length of the Chinese original: 36,371 words.
Adopted international standard: ANSI/IEEE 81-1993, IDT.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 24 pages — is available in the English PDF.
Referenced standards
How to Download GB/T 17949.1-2000
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
Secure payment via Stripe
Payments accepted
GB/T 17949.1-2000
$405.00