Valid

GB/T 17215.686-2024Electricity metering data exchange - The DLMS/COSEM suite - Part 86: High speed PLC ISO/IEC 12139-1 profile for neighbourhood networks (English PDF)

电测量数据交换 DLMS/COSEM组件 第86部分:社区网络高速PLC ISO/IEC 12139-1配置

Preview PDF

This is a limited preview

Buy now to download the full PDF (31 pages)

Need quotation for your management?

Get a formal quotation for GB/T 17215.686-2024 in 30 minutes.

Issued by

State Administration for Market Regulation, China National Standardization Administration

Level / Type

National · Recommended

Issue date

September 29, 2024

Implementation date

April 1, 2025

Scope

GB/T 17215.686-2024 is the English-translated version of 电测量数据交换 DLMS/COSEM组件 第86部分:社区网络高速PLC ISO/IEC 12139-1配置.

GB/T 17215.686-2024 — This document specifies the DLMS/COSEM communication configuration for ISO/IEC 12139-1 High Speed PLC (HS-PLC) Community Networks. This document applies to high-speed PLCs specified in ISO/IEC 12139-1.

Found what you need?

Document preview — GB/T 17215.686-2024

National Standard of the People's Republic of China

ICS
17.220.20
Classification
N 22

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • Preface
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms, definitions and abbreviations
  • 3.1 Terms and Definitions
  • 3.2 Abbreviations
  • 4 Target communication environment
  • 5 Usage of this configuration communication layer
  • 5.1 Information related to the use of the standard that specifies the lower layer
  • 5.2 Structure of communication configuration
  • 5.3 Lower protocol layers and their use
  • 5.3.1 Overview
  • 5.3.2 Physical Layer
  • 5.3.3 MAC layer
  • 5.4 Service Mapping and Adaptation Layer
  • 5.4.1 Overview
  • 5.4.2 Common Part Adaptation Sublayer (CPAS)
  • 5.4.3 IP Specific Service Adaptation Sublayer (SSAS)
  • 5.4.4 HDLCSSAS
  • 5.5 Registration and Connection Management
  • 6 Identification and addressing schemes
  • 7 Specific considerations for application layer services
  • 7.1 Overview
  • 7.2 Establishment and release of application connection. ACSE service
  • 7.3 XDLMS Service
  • 7.4 Security Mechanism
  • 7.5 Transmission of long application messages
  • 7.6 Media access, bandwidth, and timing considerations
  • 7.7 Other Notes
  • 8 Communication Configuration and Management
  • 9 COSEM Applications
  • 10 Other things to note when using this configuration
  • Appendix A (Informative) Example
  • A.1 IP-based communication example
  • A.2 Communication Example Based on HDLC
  • A.2.1 Example 1.Establishment of data link layer connection (SNRM-UA exchange)
  • A.2.2 Example 2.Establishing AA (AARQ-AARE Exchange)
  • A.2.3 Example 3.Data Communication (Get-request)
  • A.2.4 Example 4.Example of disconnecting with Releasing (DISC)
  • Appendix B (Normative) COSEM interface class for data exchange using HS-PLC ISO/IEC 12139-1 community network
  • B.1 Overview
  • B.2 DLMS/COSEM interface class for setting up and managing HS-PLC ISO/IEC 12139-1 networks
  • B.2.1 Overview
  • B.2.2 HS-PLCISO /IEC 12139-1MACsetup(class_id=140,version=0)
  • B.2.3 HS-PLCISO /IEC 12139-1CPASsetup(class_id=141,version=0)
  • B.2.4 HS-PLCISO /IEC 12139-1IPSSASsetup(class_id=141,version=0)
  • B.3 Relationship with OBIS
  • B.3.1 Use of value group C
  • B.3.2 Objects for data exchange using DLMS/COSEM HS-PLC ISO/IEC 12139-1 network
  • Reference

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1: Structure and drafting rules for standardization documents" Drafting.

This document is part 86 of GB/T (Z) 17215.6 "DLMS/COSEM components for electrical measurement data exchange".

The following parts have been published.

--- Part 10: Standardized framework for intelligent measurement;

--- Part 11: Template for DLMS/COSEM communication configuration standard;

--- Part 31: Use of local area networks based on twisted pair carrier signals;

--- Part 46: Data link layer using HDLC protocol;

--- Part 47: DLMS/COSEM transport layer based on IP network;

--- Part 51: Application layer protocol;

--- Part 52: Communication protocol management distribution line message specification (DLMS) server;

--- Part 53: DLMS/COSEM application layer;

--- Part 61: Object Identification System (OBIS);

--- Part 62: COSEM interface class;

--- Part 69: Common Information Model Message Set (IEC 61968-9) and DLMS/COSEM (IEC 62056) data model and coordination Mapping between proposals;

--- Part 73: Wired and wireless M-Bus communication configurations for local and community networks;

--- Part 75: Local data transmission configuration for local network (LN);

--- Part 76: Connection-oriented layer 3 communication configuration based on HDLC;

--- Part 82: Community Network Mesh Communication Configuration;

--- Part 86: Community network high-speed PLC ISO/IEC 12139-1 configuration;

--- Part 91: Communication using Web services to access DLMS/COSEM servers via COSEM Access Service (CAS) Configuration;

--- Part 97: Communication configuration based on TCP-UDP/IP network.

This document is equivalent to IEC 62056-8-6:2017 "Electrical measurement data exchange DLMS/COSEM components Part 8-6.Community Network High Speed PLC ISO/IEC 12139-1 Configuration.

The following minimal editorial changes were made to this document.

--- In order to coordinate with the existing standards, the name of the standard is changed from "Electrical Measurement Data Exchange DLMS/COSEM Components Part 8-6.Social the "High-speed PLC ISO/IEC 12139-1 Configuration for Area Networks" was changed to "DLMS/COSEM Components for Electrical Measurement Data Exchange Part 86: Community network high-speed PLC ISO/IEC 12139-1 configuration.

Introduction

At present, energy conservation, emission reduction, low carbon, environmental protection and the establishment of a sustainable society have become a global consensus. Countries are actively building regional energy management system to promote efficient and scientific use of energy. On this basis, IEC/TC57 (Power System Management and Related Information Exchange Technology) the EN/TC294 (Technical Committee for Instrument Communication Systems) and TC13 (Technical Committee for Power Measurement and Control) jointly established DLMS/COSEM energy measurement system transmission protocol, the electrical energy part is completed by IEC 62056 (all parts), and the non-electrical part is completed by EN13757 (all parts) is completed. In order to establish a global unified and open interoperability, countries around the world have successively adopted IEC 62056 (all parts) Transformed into national standards. my country transformed IEC 62056-XY into GB/T 17215.6XY.

GB/T 17215.6 "Electrical Measurement Data Exchange DLMS/COSEM Components" is intended to consist of the following 27 parts.

--- Part 10: Intelligent measurement standardization framework. The purpose is to understand the architecture, interoperability, and information security of GB/T 17215.6 and other relevant information.

--- Part 11: Template for DLMS/COSEM communication configuration standard. The purpose is to establish the communication configuration standard to follow template.

--- Part 31: Local area network based on twisted pair carrier signal. The purpose is to use twisted pair carrier signal local area network to comply with specifications.

--- Part 41: Data exchange using wide area networks. Public switched telephone network (PSTN) with LINK protocol.

Specifications followed by the Public Switched Telephone Network with the LINK protocol.

--- Part 42: Physical layer service procedures for connection-oriented asynchronous data exchange. The purpose is to establish the physical layer service procedures for asynchronous data exchange.

The layer connection process should follow the specifications

--- Part 46: Data link layer using HDLC protocol. The purpose is to use the HDLC asynchronous communication protocol suite to follow the data Link layer specifications.

--- Part 47: DLMS/COSEM transport layer based on IP network.

The COSEM transport layer follows the specification.

--- Part 51: Application layer protocol. The purpose is to provide the transport layer and metering equipment communication architecture described in DL/T 790.441 ization application layer.

--- Part 52: Communication protocol management distribution line message specification (DLMS) server. The purpose is to provide IEC 62056-31, IEC the protocol management DLMS server of IEC 62056-41 and IEC 62056-51 is consistent with and different from DL/T 790.441.

--- Part 53: DLMS/COSEM application layer. The purpose is to give the application of DLMS/COSEM client and server Layer structure, services and protocols.

--- Part 58: Smart Message Language (SML). The purpose is to provide a XML-based grammar for constructing SML for use in TCP/IP Internet language.

--- Part 61: Object Identification System (OBIS). The purpose is to specify unique identifiers for data in electrical measuring equipment.

--- Part 62: COSEM interface class. The purpose is to specify the instrument model and build the instrument function in the form of interface class.

--- Part 69: Common Information Model Message Set (IEC 61968-9) and DLMS/COSEM (IEC 62056) data model and coordination the purpose is to provide the mapping between CIM and DLMS/COSEM required for information exchange with the master ERP.

--- Part 73: Wired and wireless M-Bus communication configuration for local and community networks. The purpose is to use wired and wireless M-bus the model follows the specification.

--- Part 75: Local data transmission configuration for local network (LN). The purpose is to use the specifications followed by the local network mode.

--- Part 76: Connection-oriented three-layer communication configuration based on HDLC.

The DLMS/COSEM three-layer model follows the specifications.

--- Part 82: Community Network Mesh Communication Configuration. The purpose is to use the wireless mesh mode to follow the specification.

--- Part 83: Community Network PLCS-FSK Communication Configuration. The purpose is to use the PLCS-FSK mode to follow the specifications.

--- Part 84: Narrowband OFDMPRIME PLC communication configuration for community networks. The purpose is to use OFDMPRIME the PLC mode follows the specification.

--- Part 85: Community network narrowband OFDMG3-PLC network communication configuration. The purpose is to use OFDMG3-PLC mode Specifications to follow.

--- Part 86: Community network high-speed PLC ISO/IEC 12139-1 configuration. The purpose is to use PLC ISO/IEC 12139-1 the specification that the pattern follows.

--- Part 88: Communication configuration for ISO/IEC 14908 series networks. The purpose is to use the ISO/IEC 14908 model to follow the specification.

--- Part 811: Wi-SUN community mesh network communication configuration. The purpose is to use the Wi-SUN mode to follow the specification.

--- Part 812: Low Power Wide Area Network (LPWAN) Communication Configuration. The purpose is to use the specifications followed by the LPWAN mode.

--- Part 91: Communication configuration for accessing DLMS/COSEM servers via COSEM Access Service (CAS) using Web services the purpose is to adopt the specifications followed by the Web server model.

--- Part 97: Communication configuration based on TCP-UDP/IP network. The purpose is to use the TCP-UDP/IP mode to follow specification.

According to the definition of IEC 62056-1-0, IEC 62056 (all parts) DLMS/COSEM components are for communication related to smart metering the medium provides a specific communication configuration standard.

Such communication profile standards specify how to use the COSEM data model and DLMS/COSEM application layer.

Communication profile standard refers to the communication standard part of IEC 62056 (all parts) DLMS/COSEM components or other open communication Letter standard.

This document specifies DLMS/COSEM communication for community networks using high-speed PLC (HS-PLC) technology compliant with ISO/IEC 12139-1.

Profile. The technology is based on discrete multi-tone (DMT) modulation. It can be used in low-voltage or medium-voltage distribution networks. High-speed PLC physical layer (PHY) the rate is usually 24Mbps, but data throughput varies depending on the low or medium voltage power line. Although high-speed PLC can be used for the low voltage grid can also be used for the medium voltage grid, but in this document HS-PLC is only considered for low voltage.

When implementing advanced services based on DLMS/COSEM profiles, such as complex tariff plans, data security measures, demand response the community network can become a bottleneck for bidirectional consumer data exchange, etc. High-speed PLC technology minimizes this bottleneck due to the high data rates available.

In addition, high-speed PLC can accommodate larger amounts of data, so it can also be used to support other applications, such as the Internet of Things (IoT).

DLMS/COSEM components for electrical measurement data exchange Part 86: Community Network High-Speed PLC ISO/IEC 12139-1 Configuration

1 Scope

This document specifies the DLMS/COSEM communication configuration for ISO/IEC 12139-1 High Speed PLC (HS-PLC) Community Networks.

This document applies to high-speed PLCs specified in ISO/IEC 12139-1.

2 Normative references

The contents of the following documents constitute essential clauses of this document through normative references in this document.

For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to this document.

IEC 62056-5-3 Electrical measurement data exchange DLMS/COSEM components Part 5-3.DLMS/COSEM application layer (Electricity Metering Data Exchange-The DLMS/COSEM suite-Part 5-3.DLMS/COSEM Note. GB/T 17215.653-2018 Electrical measurement data exchange DLMS/COSEM components Part 53: DLMS/COSEM application layer (IEC 62056-5-3:2017, IDT).

IEC 62056-6-2 Electrical measurement data exchange DLMS/COSEM components Part 6-2.COSEM interface class ses) Note. GB/T 17215.662-2018 Electrical measurement data exchange DLMS/COSEM components Part 62: COSEM interface class (IEC 62056-6-2:2017,IDT).

IEC 62056-7-6 Electrical measurement data exchange DLMS/COSEM components Part 7-6.Connection-oriented three-way communication based on HDLC Note. GB/T 17215.676-2018 Electrical measurement data exchange DLMS/COSEM component Part 76: Connection-oriented layer 3 communication based on HDLC Signal configuration (IEC 62056-7-6:2013, IDT).

IEC 62056-9-7 Electrical measurement data exchange DLMS/COSEM components Part 9-7.TCP-UDP/IP based network profile for TCP-UDP/IP networks) Note. GB/T 17215.697-2018 Electrical measurement data exchange DLMS/COSEM components Part 97: Communication based on TCP-UDP/IP network Configuration (IEC 62056-9-7:2013, IDT).

ISO/IEC 12139-1 Information technology - Communications and information exchange between systems - Power line communication (PLC) - High-speed PLC media access

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 31 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 17215.686-2024

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
31 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 17215.686-2024

$545.00