Valid

GB/T 17215.646-2018Electricity metering data exchange -- The DLMS/COSEM suite -- Part 46: Data link layer using HDLC protocol (English PDF)

电测量数据交换 DLMS/COSEM组件 第46部分:使用HDLC协议的数据链路层

Preview PDF

This is a limited preview

Buy now to download the full PDF (98 pages)

Need quotation for your management?

Get a formal quotation for GB/T 17215.646-2018 in 30 minutes.

Issued by

State Administration for Market Regulation, China National Standardization Administration

Level / Type

National · Recommended

Issue date

December 28, 2018

Implementation date

July 1, 2019

Scope

GB/T 17215.646-2018 is the English-translated version of 电测量数据交换 DLMS/COSEM组件 第46部分:使用HDLC协议的数据链路层.

GB/T 17215.646-2018 is the Chinese standard "Electricity metering data exchange -- The DLMS/COSEM suite -- Part 46: Data link layer using HDLC protocol". Its scope clause reads: This part of GB/T 17215.6 specifies a data link layer for connection-oriented, HDLC-based, asynchronous communication protocol sets.

To ensure a consistent data link layer service specification for both connection-oriented and connection-free operation, the data link layer is divided into two Sublayer. logical link control sublayer (LLCsub-layer) and medium access control sublayer (MACsub-layer).

This section supports the following communication environments. ---Point-to-point and point-to-multipoint configuration; --- Dedicated and switched data transmission equipment; ---Half duplex and full duplex connection; --- Asynchronous start/stop transmission, 1 start bit, 8 data bits, no parity, 1 stop bit.

At the same time, the following two special procedures are defined. --- The separately received service user layer PDU part is transmitted from the server side to the client in a transparent manner.

Server side service The user layer can send its PDU to the data link layer in fragmented form, and the data link layer can hide the fragment for the client side; --- An event report by sending a UI frame from the slave to the primary station.

Appendix B explains the role of data models and protocols for data exchange in electricity meters.

Found what you need?

Document preview — GB/T 17215.646-2018

National Standard of the People's Republic of China

ICS
17.220.20
Classification
N 22
Replacing
GB/T 19897.4-2005

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions and abbreviations
  • 3.1 Terms and Definitions
  • 3.2 Abbreviations
  • 4 Overview
  • 4.1 LLC Sublayer
  • 4.2 MAC Sublayer
  • 4.3 Specification Method
  • 5 LLC sublayer
  • 5.1 The role of the LLC sublayer
  • 5.2 LLC Sublayer Service Specification
  • 5.3 LLC Sublayer Protocol Specification
  • 6 MAC sublayer
  • 6.1 HDLC selection
  • 6.2 MAC sublayer service specification
  • 6.3 Physical layer services used by the MAC sublayer
  • 6.4 MAC Sublayer Protocol Specification
  • Appendix A (informative) FCS calculation
  • Appendix B (informative) Data Models and Protocols
  • Appendix C (informative) Data Link Layer Management Service

1 Scope

This part of GB/T 17215.6 specifies a data link layer for connection-oriented, HDLC-based, asynchronous communication protocol sets.

To ensure a consistent data link layer service specification for both connection-oriented and connection-free operation, the data link layer is divided into two

Sublayer. logical link control sublayer (LLCsub-layer) and medium access control sublayer (MACsub-layer).

This section supports the following communication environments.

---Point-to-point and point-to-multipoint configuration;

--- Dedicated and switched data transmission equipment;

---Half duplex and full duplex connection;

--- Asynchronous start/stop transmission, 1 start bit, 8 data bits, no parity, 1 stop bit.

At the same time, the following two special procedures are defined.

--- The separately received service user layer PDU part is transmitted from the server side to the client in a transparent manner. Server side service

The user layer can send its PDU to the data link layer in fragmented form, and the data link layer can hide the fragment for the client side;

--- An event report by sending a UI frame from the slave to the primary station.

Appendix B explains the role of data models and protocols for data exchange in electricity meters.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.

Pieces. For undated references, the latest edition (including all amendments) applies to this document.

IEC 60050-300.2001 Electrotechnical terminology - Electrotechnical measurement and instrumentation - Part 311. General terms

Part 312. General terms for electrical measurements - Part 313. Types of electrical measuring instruments - Part 314. Special

Language (InternationalElectrotechnicalVocabulary-Electricalandelectronicmeasurementsandmeasuring instruments-Part 311.Generaltermsrelatingtomeasurements-Part 312.Generaltermsrelatingto electricaleasurements-Part 313. Typesofelectricalmeasuringinstruments-Part 314.Specificterms

Accordingtothetypeofinstrument)

IEC /T R62051.1999 Electrical measurement terms (Electricity metering-Glossary of terms)

IEC 62051-1.2004 Terms of data exchange for metering, tariffs and load control - Part 1. Part 1

COSEM measuring equipment exchanges data related terms (Electricity metering-Dataexchangeformeterreading, tariffandloadcontrol-GlossaryofTerms-Part 1,Termsrelatedtodataexchangewithmetering equipmentusingDLMS/COSEM)

IEC 62056-42.2002 Data exchange for metering, rate and load control - Part 42. Connection-oriented asynchronous data

Exchanged physical layer service process (Electricity metering-Dataexchangeformeterreading, tariffandloadcon- trol-Part 42. Physicallayerservicesandproceduresforconnectionorientedasynchronousdataex-

Change)

IEC 62056-53.2006 Data exchange for electrical measurement meter reading, rates and load control - Part 53. COSEM application layer (ElectricitymeteringDataexchangeformeterreading,tariffandloadcontrolPart 53.COSEMAppli-

GB/T 15284 | GB/T 17215.321 | GB/T 34067.2 | GB/Z 17215.652 | GB/Z 17215.651 | GB/T 17215.647 | […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 98 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 17215.646-2018

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
98 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 17215.646-2018

$650.00