GB/T 17215.631-2018Electricity metering data exchange -- The DLMS/COSEM suite -- Part 31: Use of local area networks on twisted pair with carrier signalling (English PDF)
Also coversGBT17215.631-2018
Open the GB/T 17215.631-2018 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
December 28, 2018
Implementation date
July 1, 2019
Scope
GB/T 17215.631-2018 (Electricity metering data exchange -- The DLMS/COSEM suite -- Part 31: Use of local area networks on twisted pair with carrier signalling) is available as an English-translated PDF.
GB/T 17215.631-2018 — This part of GB/T 17215.6 specifies three protocol structures for local bus data exchange between active stations or passive stations. Which for none The source station will be powered by the bus for data exchange. Support for three different structures. ---Basic structure. This three-layer protocol structure provides remote transmission services; Note 1. This protocol structure has been published in the basic protocol IEC 61142.1993 and has become the famous Euridis standard. ---With DLMS structure. This structure allows the use of DLMS services, as described in detail in IEC 61334-4-41; Note 2. This protocol structure has been published in IEC 62056-31.1999. --- with DLMS/COSEM structure. this structure allows the use of DLMS/COSEM application layer and COSEM object model, Each is described in detail in IEC 62056-5-3.2013 and IEC 62056-6-2.2013. The three protocol structures use the same physical layer and are fully compatible, which means that devices implementing these protocol structures can be in the same Run on a bus. The transmission medium is a twisted pair using a carrier signal, which is called an Euridis bus.
Document preview — GB/T 17215.631-2018
National Standard of the People's Republic of China
- ICS
- 17.220.20
- Classification
- N 22
- Replacing
- GB/T 19897.2-2005
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 4 Datacommunicationprotocols-Section41. Applicationprotocols-Distributionlinemessagespec-
Foreword
GB/T 17215 "AC measuring equipment" is divided into several parts, GB/T 17215.6 "Electrical measurement data exchange DLMS/COSEM
Components are divided into the following sections.
--- Part 10. Intelligent Measurement Standardization Framework;
--- Part 11. DLMS/COSEM communication configuration standard template;
--- Part 31. Local area network use based on twisted pair carrier signals;
--- Part 46. Data link layer using HDLC protocol;
--- Part 47. DLMS/COSEM transmission layer based on IP network;
--- Part 53. DLMS/COSEM application layer;
--- Part 61. Object Identification System (OBIS);
--- Part 62. COSEM interface class;
--- Part 73. Wired and wireless M-Bus communication configurations for local and community networks;
--- Part 76. HDLC-based connection-oriented three-layer communication configuration;
--- Part 91. Communication configuration using the WEB service to access the COSEM server via CAS;
--- Part 97. Communication configuration based on TCP-UDP/IP network.
This part is the 31st part of GB/T 17215.6.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This part replaces GB/T 19897.2-2005 "Automated meter reading system low-level communication protocol Part 2. Based on twisted pair carrier signal
The use of LAN, the main technical changes compared with GB/T 19897.2-2005 are as follows.
--- Added a protocol structure that uses the DLMS/COSEM application layer of IEC 62056 and the COSEM object model;
--- Redefine the data link layer, which is divided into two parts.
* pure data link layer;
* Management support entities that manage the media.
--- Negotiate the transmission rate, you can increase the baud rate to 9600 baud.
This section uses the translation method equivalent to IEC 62056-3-1.2013 "Electrical Measurement Data Exchange DLMS/COSEM Components Section 3-1
Part. LAN Usage Based on Twisted Pair Carrier Signals.
The documents of our country that have a consistent correspondence with this section are as follows.
---GB/T 15127-2008 Telecommunication and information exchange between information technology systems Twisted pair multi-point interconnection (ISO /IEC
8482.1993, IDT);
---GB/T 17215.653-2018 Electrical Measurement Data Exchange DLMS/COSEM Components Part 53. DLMS/CO-
SEM application layer (IEC 62056-5-3..2017, IDT);
---DL/T 790.441-2004 Distribution automation using distribution line carriers - Part 4-41. Data communication protocol application layer
Protocol - Distribution Line Message Specification (IEC 61334-4-41.1996, IDT).
This section has made the following editorial changes.
--- The standard name was changed from Section 3-1 to Part 31;
1 Scope
This part of GB/T 17215.6 specifies three protocol structures for local bus data exchange between active stations or passive stations. Which for none
The source station will be powered by the bus for data exchange.
Support for three different structures.
---Basic structure. This three-layer protocol structure provides remote transmission services;
Note 1. This protocol structure has been published in the basic protocol IEC 61142.1993 and has become the famous Euridis standard.
---With DLMS structure. This structure allows the use of DLMS services, as described in detail in IEC 61334-4-41;
Note 2. This protocol structure has been published in IEC 62056-31.1999.
--- with DLMS/COSEM structure. this structure allows the use of DLMS/COSEM application layer and COSEM object model,
Each is described in detail in IEC 62056-5-3.2013 and IEC 62056-6-2.2013.
The three protocol structures use the same physical layer and are fully compatible, which means that devices implementing these protocol structures can be in the same
Run on a bus.
The transmission medium is a twisted pair using a carrier signal, which is called an Euridis bus.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only the dated version applies to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
IEC 61334-4-41.1996 Distribution automation using distribution line carrier systems Part 4. Data communication protocols Section 41.
Application Protocol Distribution Line Message Specification (Distributionautomationusingdistributionlinecarriersystems-Part
4 Datacommunicationprotocols-Section41. Applicationprotocols-Distributionlinemessagespec-
Identification)
IEC 62056-51.1998 Electrical measurement data exchange, meter reading, rate and load control - Part 51. Application layer protocol
(Electricitymeteringdataexchangeformeterreading,tariffandloadcontrol-Part 51.Application
Layerprotocols)
IEC 62056-5-3.2013 Electrical Measurement Data Exchange DLMS/COSEM Components Part 5-3. DLMS/COSEM
Use layer (Electricity meteringdataexchange-TheDLMS/COSEMsuite-Part 5-3. DLMS/COSEMap-
Plioationlayer)
ISO /IEC 8482.1993 Telematics and information exchange between information technology systems - Twisted pair multi-point interconnection (Information
technology-Telecommunications and information exchange between systems-Twisted pair
Multipointinterconnections)
EIA485 Standard for balancing the electrical characteristics of transmitters and receivers of digital multipoint systems (Standardforlectrical
Characteristicsofgeneratorsandreceiversforuseinbalanceddigitalmultipointsystems)
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
IEC 61334
How to Buy GB/T 17215.631-2018
- 1Add to cart. Click the "Buy GB/T 17215.631-2018" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 17215.211-2021 — Electricity metering equipment(AC) - General requirements, tests and test conditions - Part 11: Metering equipment
GB/T 17215.221-2021 — Electricity metering equipment(a. c. ) - General requirements, tests and test conditions - Part 21: Tariff and load control equipment
GB/T 17215.231-2021 — Electricity metering equipment (AC) - General requirements, tests and test conditions - Part 31: Product safety requirements and tests
Secure payment via Stripe
Payments accepted
GB/T 17215.631-2018
$1,680.00