Valid

GB/T 17213.14-2018Industrial-process control valves -- Part 8-2: Noise considerations -- Laboratory measurement of noise generated by hydrodynamic flow through control valves (English PDF)

工业过程控制阀 第8-2部分:噪声的考虑 实验室内测量液动流流经控制阀产生的噪声

Preview PDF

This is a limited preview

Buy now to download the full PDF (30 pages)

Need quotation for your management?

Get a formal quotation for GB/T 17213.14-2018 in 30 minutes.

Issued by

State Administration for Market Regulation, China National Standardization Administration

Level / Type

National · Recommended

Issue date

July 13, 2018

Implementation date

February 1, 2019

Scope

GB/T 17213.14-2018 is the English-translated version of 工业过程控制阀 第8-2部分:噪声的考虑 实验室内测量液动流流经控制阀产生的噪声.

GB/T 17213.14-2018 is the Chinese standard "Industrial-process control valves -- Part 8-2: Noise considerations -- Laboratory measurement of noise generated by hydrodynamic flow through control valves".

Its scope clause reads: This part of GB/T 17213 specifies the measurement method of the sound pressure level generated by the flow of hydraulic fluid through the control valve and determines the determination due to cavitation.

A method that uses characteristics that cause an increase in noise. This section also specifies the requirements for measuring airborne noise in the laboratory to determine these characteristics.

Equipment, methods and procedures. These two methods are mainly used to test the characteristics of noise generated by the control valve.

The first method is to measure the radiated noise generated by the control valve and associated test piping [including the fixed throttling device through which the test fluid (water) flows] A unified approach to sound (see Note 1).

The noise standard is expressed by determining the sound pressure level of the control valve under test. The second method is to measure the sound pressure level in the upstream and downstream piping systems of the control valve under fixed operating conditions.

Due to the elimination of the pipeline Inaccuracy of transmission, this method should be preferred to evaluate the acoustic characteristics of the control valve.

The noise characteristics can be used for the following purposes. a) determining the acoustic characteristics of the control valve and valve assembly and the characteristic differential pressure ratio coefficient of the control valve xFz; b) predicting the noise of the control valve for a given process condition; c) compare the performance of different control valves and various measurement results; d) develop measures to extend working life and reduce noise; e) determine the possible adverse effects on the measurement of the ultrasonic flowmeter; f) Determine the size of the sound absorbing device.

Note 1. This section does not apply to test fluids other than water or control valves without downstream piping. Note 2. The coefficient xFz is used for the noise prediction method described in IEC 60534-8-4.

Found what you need?

Document preview — GB/T 17213.14-2018

National Standard of the People's Republic of China

ICS
17.140.20; 23.060.40; 25.040.40
Classification
N 16

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 symbol
  • 5 General Test Rules
  • 5.1 General
  • 5.2 Pressure regulating device
  • 5.3 Sound insulation of test samples
  • 5.4 Test section pipe
  • 5.5 Pressure tapping hole
  • 5.6 Acoustic environment
  • 5.7 Measuring instrument
  • 6 External sound pressure measurement
  • 6.1 General
  • 6.2 Noise measuring instrument
  • 6.3 Accuracy of test data
  • 6.4 Test data
  • 7 Internal sound pressure measurement
  • 7.1 Test System
  • 7.2 Noise measuring instrument
  • 7.3 Test fluid
  • 7.4 Background noise
  • 7.5 Position of the sound level sensor
  • 7.6 Accuracy of test data
  • 7.7 Test data
  • 7.8 Accuracy
  • 7.9 Data Evaluation
  • 8 Determine the characteristic differential pressure ratio xFz
  • 8.1 General
  • 8.2 Test procedure
  • 8.3 Determining xFz

1 Scope

This part of GB/T 17213 specifies the measurement method of the sound pressure level generated by the flow of hydraulic fluid through the control valve and determines the determination due to cavitation.

A method that uses characteristics that cause an increase in noise. This section also specifies the requirements for measuring airborne noise in the laboratory to determine these characteristics.

Equipment, methods and procedures.

These two methods are mainly used to test the characteristics of noise generated by the control valve.

The first method is to measure the radiated noise generated by the control valve and associated test piping [including the fixed throttling device through which the test fluid (water) flows]

A unified approach to sound (see Note 1). The noise standard is expressed by determining the sound pressure level of the control valve under test.

The second method is to measure the sound pressure level in the upstream and downstream piping systems of the control valve under fixed operating conditions. Due to the elimination of the pipeline

Inaccuracy of transmission, this method should be preferred to evaluate the acoustic characteristics of the control valve.

The noise characteristics can be used for the following purposes.

a) determining the acoustic characteristics of the control valve and valve assembly and the characteristic differential pressure ratio coefficient of the control valve xFz;

b) predicting the noise of the control valve for a given process condition;

c) compare the performance of different control valves and various measurement results;

d) develop measures to extend working life and reduce noise;

e) determine the possible adverse effects on the measurement of the ultrasonic flowmeter;

f) Determine the size of the sound absorbing device.

Note 1. This section does not apply to test fluids other than water or control valves without downstream piping.

Note 2. The coefficient xFz is used for the noise prediction method described in IEC 60534-8-4.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.

Pieces. For undated references, the latest edition (including all amendments) applies to this document.

GB/T 3785.1-2010 Electroacoustic sound level meters - Part 1. Specification (IEC 61672-1.2002, IDT)

GB/T 17213.1-2015 Industrial process control valves - Part 1. Terminology and general rules for control valves (IEC 60534-1.2005, IDT)

GB/T 17213.9-2005 Industrial process control valves - Part 2-3. Circulation capacity test procedures (IEC 60534-2-3.

1997, IDT)

ISO 3744.1994 Acoustic sound pressure method for the determination of the approximate free field above the acoustic power level of the noise source (Acous- tics-Determinationofsoundpowerlevelsofnoisesourcesusingsoundpressure-Engineering

Methodsinanessentialyfreefieldconditionsoverareflectingplane)

ISO 3745.2003 Acoustic sound pressure method for the determination of noise source sound power level anechoic chamber and semi-anechoic chamber precision method (Acoustics-De-

Terminationofsoundpowerlevelsofnoisesourcesusingsoundpressure-Precisionmethodsforane-

Choicandhemi-anechoicrooms)

IEC 60534-8-4 Industrial Process Control Valves - Part 8-4. Noise Considerations Noise Predictions from Fluid Flow Through Control Valves

Method (Industrial-processcontrolvalves-Part 8-4. Noiseconsiderations-Predictionofnoisegenerated

Byhydrodynamicflow)

GB/T 17213.8 | GB/T 17213.4 | GB/T 17213.18 | GB/T 17213.9 | GB/T 17213.7 | GB/T 17213.15 | […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 30 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 17213.14-2018

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
30 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 17213.14-2018