GB/T 17147-2012Measurement of audio-frequency noise voltage level in sound broadcasting (English PDF)
Also coversGBT17147-2012
Open the GB/T 17147-2012 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Level / Type
National · Recommended
Issue date
June 29, 2012
Implementation date
October 1, 2012
Scope
GB/T 17147-2012 (Measurement of audio-frequency noise voltage level in sound broadcasting) is available as an English-translated PDF.
GB/T 17147-2012 — This standard specifies the sound broadcasting audio noise level measurement method for the desired weighting network features, characteristics and measurement instruments Measurement methods. This standard applies to audio production, sound recording and reproducing system and audio broadcasting system measurement noise level.
Document preview — GB/T 17147-2012
National Standard of the People's Republic of China
- ICS
- 33.160.01
- Classification
- M 60
- Replacing
- GB/T 17147-1997
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Contents
- 1 Scope1
- Label 12
- 3 Measurement1
Foreword
This standard rule according to GB/T 1.1-2009 given draft.
This standard replaces GB/T 17147-1997 "sound broadcasting audio noise level measurements."
This standard and GB/T 17147-1997 compared to the main technical changes are as follows.
--- Weighted network in the frequency response 31500Hz by -47.7dB to -42.7dB (see Table 1);
--- Adds a new level to achieve noise measurement weighting network circuit (see Appendix A).
This standard uses the translation method is equivalent to using ITU-RBS.468-4.2002 "sound broadcasting audio noise level measurements."
This standard made the following editorial changes.
--- Increasing the Code chapter;
--- Increased by reference.
This standard was proposed by the State Administration of Radio, Film and Television.
This standard by the National Film and Television Broadcasting Standardization Technical Committee (SAC/TC239) centralized.
This standard was drafted. the State Administration of Radio, Film Radio and Television Planning Institute.
Drafters of this standard. any instrument, Marvin, Cui Junsheng, Xiao Hui, Zhang Qian.
Sound broadcasting audio noise level measurement
1 Scope
This standard specifies the sound broadcasting audio noise level measurement method for the desired weighting network features, characteristics and measurement instruments
Measurement methods.
This standard applies to audio production, sound recording and reproducing system and audio broadcasting system measurement noise level.
2 Code
The following codes apply to this document.
dBqps
Taken as a reference voltage of 0.775V RMS, quasi-peak noise meter with a weighted measure (sound program transmission weight), expressed in decibels of the absolute
Voltage level.
[GB/T 3383-1982,2.12]
3 Measurement Methods
3.1 weighted network
Measurements should be selected in line with the requirements of this quasi-peak meter, such as the use of weighted networks, it should also be used in line with the requirements of this weighting
The internet.
Figure 1 shows the circuit diagram of the weighting network, Figure 2 shows the nominal frequency weighting network response curve. Table 1 shows at different frequencies
Response values. Tolerance response curve and the nominal curve and weighted by the amplifier network of measuring equipment between FIG. 3, Table
The last column gives 1.
When used with 3.1 audio noise weighting network measurements, measuring instruments comply with 3.2 should be a quasi-peak table using any
What other instruments (such as the root mean square value tables) for such measurements would cause the measured signal to noise ratio is not directly related to the use of the standard instrument characteristics
The table compares the measured SNR.
Instrumentation (including weighting network) at 1kHz at calibration, see 3.2.6.
1 simple form of weighting network
Component values \u200b\u200btolerance and maximum 1% tolerance (1000Hz 10000Hz in the Q value of not less than 200, to meet given in Table 1
And the difference between the response of 6300Hz at, or by changing capacitor 33.06nF more precisely adjusted through the use of active filter).
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
How to Buy GB/T 17147-2012
- 1Add to cart. Click the "Buy GB/T 17147-2012" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 47719-2026 — Micro-electromechanical systems (MEMS) technology - Test methods for the performance of MEMS capacitive microphones
GB/T 47600.4-2026 — Product information description for e-commerce transactions - Part 4: Home building materials
GB/T 47541-2026 — Specification for the competency assessment of science and technology evaluation organizations
Secure payment via Stripe
Payments accepted
GB/T 17147-2012
$200.00