Valid

GB/T 17147-2012Measurement of audio-frequency noise voltage level in sound broadcasting (English PDF)

声音广播中音频噪声电平的测量

Preview PDF

This is a limited preview

Buy now to download the full PDF (25 pages)

Need quotation for your management?

Get a formal quotation for GB/T 17147-2012 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Level / Type

National · Recommended

Issue date

June 29, 2012

Implementation date

October 1, 2012

Scope

GB/T 17147-2012 is the English-translated version of 声音广播中音频噪声电平的测量.

GB/T 17147-2012 — This standard specifies the sound broadcasting audio noise level measurement method for the desired weighting network features, characteristics and measurement instruments Measurement methods.

This standard applies to audio production, sound recording and reproducing system and audio broadcasting system measurement noise level.

Found what you need?

Document preview — GB/T 17147-2012

National Standard of the People's Republic of China

ICS
33.160.01
Classification
M 60
Replacing
GB/T 17147-1997

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Contents

  • 1 Scope1
  • Label 12
  • 3 Measurement1

Foreword

This standard rule according to GB/T 1.1-2009 given draft.

This standard replaces GB/T 17147-1997 "sound broadcasting audio noise level measurements."

This standard and GB/T 17147-1997 compared to the main technical changes are as follows.

--- Weighted network in the frequency response 31500Hz by -47.7dB to -42.7dB (see Table 1);

--- Adds a new level to achieve noise measurement weighting network circuit (see Appendix A).

This standard uses the translation method is equivalent to using ITU-RBS.468-4.2002 "sound broadcasting audio noise level measurements."

This standard made the following editorial changes.

--- Increasing the Code chapter;

--- Increased by reference.

This standard was proposed by the State Administration of Radio, Film and Television.

This standard by the National Film and Television Broadcasting Standardization Technical Committee (SAC/TC239) centralized.

This standard was drafted. the State Administration of Radio, Film Radio and Television Planning Institute.

Drafters of this standard. any instrument, Marvin, Cui Junsheng, Xiao Hui, Zhang Qian.

Sound broadcasting audio noise level measurement

1 Scope

This standard specifies the sound broadcasting audio noise level measurement method for the desired weighting network features, characteristics and measurement instruments

Measurement methods.

This standard applies to audio production, sound recording and reproducing system and audio broadcasting system measurement noise level.

2 Code

The following codes apply to this document.

dBqps

Taken as a reference voltage of 0.775V RMS, quasi-peak noise meter with a weighted measure (sound program transmission weight), expressed in decibels of the absolute

Voltage level.

[GB/T 3383-1982,2.12]

3 Measurement Methods

3.1 weighted network

Measurements should be selected in line with the requirements of this quasi-peak meter, such as the use of weighted networks, it should also be used in line with the requirements of this weighting

The internet.

Figure 1 shows the circuit diagram of the weighting network, Figure 2 shows the nominal frequency weighting network response curve. Table 1 shows at different frequencies

Response values. Tolerance response curve and the nominal curve and weighted by the amplifier network of measuring equipment between FIG. 3, Table

The last column gives 1.

When used with 3.1 audio noise weighting network measurements, measuring instruments comply with 3.2 should be a quasi-peak table using any

What other instruments (such as the root mean square value tables) for such measurements would cause the measured signal to noise ratio is not directly related to the use of the standard instrument characteristics

The table compares the measured SNR.

Instrumentation (including weighting network) at 1kHz at calibration, see 3.2.6.

1 simple form of weighting network

Component values tolerance and maximum 1% tolerance (1000Hz 10000Hz in the Q value of not less than 200, to meet given in Table 1

And the difference between the response of 6300Hz at, or by changing capacitor 33.06nF more precisely adjusted through the use of active filter).

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 25 pages — is available in the English PDF.

How to Download GB/T 17147-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
25 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 17147-2012

$195.00