Scope
GB/T 16484.22-2009 is the English-translated version of 氯化稀土、碳酸轻稀土化学分析方法 第22部分:氧化锌量的测定 火焰原子吸收光谱法.
GB/T 16484.22-2009 is the Chinese standard "Chemical analysis methods of rare earth chloride and light rare earth carbonate - Part 22: Determination of zinc oxide content - Flame atomic absorption spectrometry".
Its scope clause reads: GB/T 16484 provisions of this part of the determination of earth chloride and light rare earth carbonate, zinc oxide content. This section applies to the rare earth carbonate light rare earth oxide zinc contents chloride.
Measurement range. 0.010% to 1.00%. Its clauses include principle of the method; reagents and materials; instrument; sample.
Found what you need?
Document preview — GB/T 16484.22-2009
National Standard of the People's Republic of China
- ICS
- 77.120.99
- Classification
- H 14
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 principle of the method
- 3 Reagents and materials
- 4 Instrument
- 5 Sample
1 Scope
GB/T 16484 provisions of this part of the determination of earth chloride and light rare earth carbonate, zinc oxide content.
This section applies to the rare earth carbonate light rare earth oxide zinc contents chloride. Measurement range. 0.010% to 1.00%.
2 principle of the method
The sample was dissolved in nitric acid or hydrochloric acid. In acid medium, with air - acetylene flame atomic absorption spectrometer measured at a wavelength of 213.9nm
The amount of zinc absorbance by standard addition method to calculate the amount of zinc oxide.
3 Reagents and materials
3.1
nitrate (rho1.42g/mL), pure class distinctions.
3.2
Hydrogen peroxide (30%), pure class distinctions.
3.3
hydrochloric acid (l + 1), pure class distinctions.
3.4 standard zinc stock solution
Weigh accurately 0.5000g zinc metal [w1 (Zn) >=99.99%] in 200mL beaker, add 10mL
Hydrochloric acid (3.3), was added dropwise a few drops of hydrogen peroxide (3.2) and let dissolve completely after heated to boiling for a few minutes, the solution was transferred to the cooling capacity 500mL
Volumetric flask, dilute with water to volume, and mix. This solution 1mL containing 1000µg zinc.
3.5 Zinc standard solution
Pipette 10.00mL standard zinc stock solution (3.4) in 100mL volumetric flask, was added 10mL of hydrochloric acid (3.3),
Dilute with water to volume, and mix. This solution 1mL containing 100µg zinc.
3.6 Zinc standard solution
Pipette 10.00mL standard zinc solution (3.5) in 100mL volumetric flask, was added 10mL of hydrochloric acid (3.3), washed with water
Dilute to volume, and mix. This solution 1mL containing 10µg zinc.
4 Instrument
Atomic absorption spectrometer, with zinc hollow cathode lamp.
Under optimum working conditions for those who can reach the following indicators can be used.
--- Sensitivity. In the measurement of the sample solution matrix consistent solution, characterized in zinc concentration should be less than 0.005µg/mL.
--- Precision. measure 10 times the absorbance of the highest concentration of the standard solution, the standard deviation should not exceed 1% of the average absorbance; with
The lowest concentration of standard solution (not a zero standard solution) measuring the absorbance of 10 times, the standard deviation should not exceed the maximum concentration of the standard
0.5% average absorbance of the solution.
--- Linear curve. The curve is divided into five sections according to concentration, absorbance difference between the absorbance difference between the highest and the lowest segment of the segment
Ratio of not less than 0.7.
5 Sample
5.1 Preparation of rare earth chloride sample
A sample was crushed, quickly placed in a weighing bottle immediately weighed.
5.2 Preparation of light rare earth carbonate sample
weigh the sample immediately after the opening.
Step 6 Analysis
6.1 Sample
Table 1 sample was weighed, accurate to 0.0001g.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
How to Download GB/T 16484.22-2009
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 16484.23-2009 — Chemical analysis methods of rare earth chloride and light rare earth carbonate - Part 23: Determination of acid insoluble substance in light rare earth carbonate - Gravimetry
GB/T 16484.21-2009 — Chemical analysis methods of rare earth chloride and light rare earth carbonate - Part 21: Determination of iron oxide content - 1,10-phenanthroline spectrophotometry
GB/T 16484.20-2009 — Chemical analysis methods of rare earth chloride and light rare earth carbonate - Part 20: Determination of nickel oxide, manganese oxide, lead oxide, aluminum oxide, zinc oxide, thorium oxide content - Inductively coupled plasma mass spectrometry
GB/T 16484.22-2009
$105.00