GB/T 16404.3-2006Acoustics -- Determination of sound power levels of noise sources using sound intensity -- Part 3: Precision method for measurement by scanning (English PDF)

声学 声强法测定噪声源声功率级 第3部分:扫描测量精密法

Preview PDF

This is a limited preview

Buy now to download the full PDF (23 pages)

Need quotation for your management?

Get a formal quotation for GB/T 16404.3-2006 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Level / Type

National · Recommended

Issue date

May 8, 2006

Implementation date

November 1, 2006

Scope

GB/T 16404.3-2006 is the English-translated version of 声学 声强法测定噪声源声功率级 第3部分:扫描测量精密法.

GB/T 16404.3-2006 — This standard specifies a surface by measuring sound intensity measurement method to measure the components of sound power levels of noise sources method, the measurement surface shall be completely surrounded by the measured noise source.

Perpendicular to the plane of the sound intensity measurements on the area integral component of sound intensity probe is being divided into a number of adjacent partial measurement surface, covering the surface of the range along a continuous path for scanning to approximate.

Measuring instruments are measured during each scan, the average normal sound intensity component and the mean square sound pressure. Scanning operation can be achieved manually or by mechanical means.

Octave band or limited band -weighted sound power level is measured 1/3 octave band values ??to calculate. This method can be used to determine the stability of the measuring face with any of the sound source, the surface of this measurement, the measured apparent sound source and the other external sound source generates sound is stable in time.

Range of the noise source measured by the measuring surface to define the selection. This method can be used to meet all the relevant requirements of this section specified test environment.

Appendix C describes this part of the acoustic power measurement to be performed with the auxiliary test, the measurement results are used to evaluate the quality of sound power level of accuracy.

If the measured quality can not meet the requirements of this section, the measurement process should be amended in accordance with the method specified. This section does not apply to the measured sound power source is negative for any band.

This section can be used for any of the following sources of noise in the environment: With the time change does not lead to sound intensity measurement accuracy drops to an unacceptable situation, sound intensity probe will not encounter speed large or unstable flow conditions unacceptable (see 5. 2. 2, 5. 3 and 5. 4).

Found what you need?

Document preview — GB/T 16404.3-2006

National Standard of the People's Republic of China

ICS
17.140
Classification
A 59

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Contents

  • What this standard covers1
  • Document data2

What this standard covers

This standard specifies a surface by measuring sound intensity measurement method to measure the components of sound power levels of noise sources method, the measurement surface shall be completely surrounded by the measured noise source. Perpendicular to the plane of the sound intensity measurements on the area integral component of sound intensity probe is being divided into a number of adjacent partial measurement surface, covering the surface of the range along a continuous path for scanning to approximate. Measuring instruments are measured during each scan, the average normal sound intensity component and the mean square sound pressure. Scanning operation can be achieved manually or by mechanical means. Octave band or limited band -weighted sound power level is measured 1/3 octave band values ??to calculate. This method can be used to determine the stability of the measuring face with any of the sound source, the surface of this measurement, the measured apparent sound source and the other external sound source generates sound is stable in time. Range of the noise source measured by the measuring surface to define the selection. This method can be used to meet all the relevant requirements of this section specified test environment. Appendix C describes this part of the acoustic power measurement to be performed with the auxiliary test, the measurement results are used to evaluate the quality of sound power level of accuracy. If the measured quality can not meet the requirements of this section, the measurement process should be amended in accordance with the method specified. This section does not apply to the measured sound power source is negative for any band. This section can be used for any of the following sources of noise in the environment: With the time change does not lead to sound intensity measurement accuracy drops to an unacceptable situation, sound intensity probe will not encounter speed large or unstable flow conditions unacceptable (see 5. 2. 2, 5. 3 and 5. 4). In some cases, the measurement conditions are not too bad suppliers

Document data

International classification (ICS): 17.140.

Chinese classification (CCS): A59.

Estimated length of the Chinese original: 35,348 words.

Adopted international standard: ISO 9614-3-2002, IDT.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 23 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 16404.3-2006

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
23 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 16404.3-2006

$679.00