GB/T 15912.1-2009Monitoring and testing method for energy conservation of refrigerating systems - Part 1: Cold storage systems (English PDF)

制冷机组及供制冷系统节能测试 第1部分:冷库

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 15912.1-2009 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

October 30, 2009

Implementation date

May 1, 2010

Scope

GB/T 15912.1-2009 is the English-translated version of 制冷机组及供制冷系统节能测试 第1部分:冷库.

GB/T 15912.1-2009 is the Chinese standard "Monitoring and testing method for energy conservation of refrigerating systems - Part 1: Cold storage systems".

Its scope clause reads: This section GB/T 15912 specifies the use of refrigeration compressor (unit), condenser, evaporator and accessories, piping and other independent parts Energy monitoring and energy content in the test methods of the user-site installation of refrigeration systems.

This section applies to storage space larger than 500m3 freezer, refrigerator (hereinafter referred to as cold storage). This section does not apply to cave cold storage, cold storage casing stone arch, inter underground, semi-underground cold storage and cooling and freezing cold. Its clauses include terms and definitions.

Found what you need?

Document preview — GB/T 15912.1-2009

National Standard of the People's Republic of China

ICS
27.010
Classification
F 01
Replacing
GB/T 15912-1995

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 3.1 Accession buildings goods at low temperatures
  • 3.2 Cold storage buildings in the main building
  • 3.3 Overall consumption of refrigerators and cooling equipment

1 Scope

This section GB/T 15912 specifies the use of refrigeration compressor (unit), condenser, evaporator and accessories, piping and other independent parts

Energy monitoring and energy content in the test methods of the user-site installation of refrigeration systems.

This section applies to storage space larger than 500m3 freezer, refrigerator (hereinafter referred to as cold storage).

This section does not apply to cave cold storage, cold storage casing stone arch, inter underground, semi-underground cold storage and cooling and freezing cold.

2 Normative references

The following documents contain provisions which, through reference GB/T 15912 in this section constitute provisions of this section. For dated reference documents

Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section

Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.

GB/T 18517 refrigeration term

3 Terms and Definitions

GB/T 18517 and established the following terms and definitions apply to this section.

3.1 Accession buildings goods at low temperatures

Including warehouses, refrigeration compressor room, power distribution room and its subsidiary buildings (structures).

3.2 Cold storage buildings in the main building

Including cold rooms, cold rooms, freezers and building directly for its services (such as stairwells, elevators

Room, hallway, small room and other subsidiary).

3.3 Overall consumption of refrigerators and cooling equipment

Including all piping, fittings, control devices, cold consumers, and they are usually contained refrigerant and cold

Agent contact.

3.4

It means for containing refrigerant through the internal coupled to each other to form a closed refrigeration circuit, the refrigerant sucked by the circulation loop

Heat and heat.

3.5

Refrigerating capacity of the refrigeration system.

3.6

The refrigeration system of electric power consumed, a compressor, a heat exchanger fan motor, the refrigerant circulating pump, the electrical system, cooling water pump, cooling

All tower fan energy-using equipment, such as a pump refrigerant contained refrigeration system comprising consumed electric power.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB/T 15912.1

EditionTitleRevisionStatus
GB/T 15912.1-2009Monitoring and testing method for energy conservation of refrigerating systems - Part 1: Cold storage systemscurrent editionCurrent
GB/T 15912-1995Monitoring and testing method for energy conservation of refrigerating systems - Part 1: Cold storage systemsprevious editionSuperseded

This page sells the current edition, GB/T 15912.1-2009. Earlier editions are listed for reference only.

How to Download GB/T 15912.1-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included