GB/T 15470.2-2025Household electric direct-acting room heaters - Methods for measuring performance - Part 2: Additional provisions for the measurement of the radiant factor (English PDF)
This is a limited preview
Buy now to download the full PDF (17 pages)
Need quotation for your management?
Get a formal quotation for GB/T 15470.2-2025 in 30 minutes.
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
April 25, 2025
Implementation date
November 1, 2025
Scope
GB/T 15470.2-2025 (Household electric direct-acting room heaters - Methods for measuring performance - Part 2: Additional provisions for the measurement of the radiant factor) is available as an English-translated PDF.
GB/T 15470.2-2025 — This chapter of IEC 60675:1994 is applicable with the following amendments. The first and second paragraphs are replaced by the following. This document specifies the performance characteristics related to the radiant effect of domestic direct-acting electric room heaters and describes them for the reference of users.
Method for measuring emissivity. This document applies to the measurement of the emissivity of direct-acting electric room heaters for domestic use.
Found what you need?
Document preview — GB/T 15470.2-2025
National Standard of the People's Republic of China
- ICS
- 97.100.10
- Classification
- Y 63
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- Preface
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Categories
- 5 Measurement Items
- 6 General conditions for measurement
- 7 Dimensions, mass and connection to the power supply
- 8 Temperature rise of air outlet grid and outer surface
- 9 Temperature rise of the surface around the heater
- 10 Heater heating time
- 11 Indoor temperature stability
- 12 Cooling
- 13 Antifreeze Temperature
- 14 Inrush current
- 15 Heat radiation effect
- 16 Measurement of effective power
- 17 Verify the manufacturer's maximum room temperature
- Appendix A (Normative) Climate Test Chamber
- Appendix B (Informative) Information provided by the point of sale
- Appendix C (Informative) Test Report Format
- Appendix AA (normative) Determination of radiation coefficient
- Figure 101 Radiation reference plane
- Figure 102 Measurement grid
- Figure AA.1 Design features of a radiometer
- Figure AA.2 Determination of correlation coefficient for luminous radiant heaters
- Table 101 Symbol
- Table AA.1 Lamp heater calibration
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1: Structure and drafting rules for standardization documents" Drafting.
This document is Part 2 of GB/T 15470 "Performance test methods for household direct-acting room electric heaters".
The following parts have been published.
---Performance test method for household direct-acting room electric heaters;
--- Part 2: Additional provisions for emissivity measurement;
--- Part 3: Additional provisions for radiant efficiency measurement.
This document is equivalent to IEC 60675-2:2020 "Performance test methods for household direct-acting room electric heaters Part 2: Radiation "Supplementary Provisions for Measurement of Emissivity Coefficient".
The following minimal editorial changes were made to this document.
---Fij in formula (AA.3) is corrected from Figure AA.2 to Figure 102.Since there is no example of Fij in Figure AA.2, the correct example is
Figure 102.
Introduction
GB/T 15470 "Performance test methods for household direct-acting room electric heaters" aims to standardize direct-acting room electric heaters the performance testing method is planned to consist of three parts.
---Performance test method for household direct-acting room electric heaters. The purpose is to specify the performance test method for household direct-acting room electric heaters.
performance testing method.
--- Part 2: Additional provisions for the measurement of emissivity. The purpose is to specify the radiation coefficient of household direct-acting room electric heaters.
Number measurement method.
--- Part 3: Additional provisions for the measurement of radiant efficiency. The purpose is to specify the radiant efficiency of household direct-acting room electric heaters.
Rate measurement method.
Household direct-acting electric room heaters Performance Test Methods Part 2.
Additional provisions for emissivity measurements
1 Scope
This chapter of IEC 60675:1994 is applicable with the following amendments. The first and second paragraphs are replaced by the following.
This document specifies the performance characteristics related to the radiant effect of domestic direct-acting electric room heaters and describes them for the reference of users.
Method for measuring emissivity.
This document applies to the measurement of the emissivity of direct-acting electric room heaters for domestic use.
2 Normative references
Chapter 2 of IEC 60675:1994 is replaced by the following.
The contents of the following documents constitute essential clauses of this document through normative references in this document.
For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to this document.
GB/T 15470.3-2025 Performance test methods for household direct-acting room electric heaters Part 3: Measurement of radiant efficiency Additional provisions (IEC 60675-3:2020, IDT) IEC 60675:1994/AMD1.1998 IEC 60675:1994/AMD2.2018 Note. GB/T 15470-2002 Performance test method for household direct-acting room electric heaters (idtIEC 60675.1994)
3 Terms and definitions
Chapter 3 of IEC 60675:1994 is replaced by the following.
IEC 60675:1994, IEC 60675:1994/AMD1.1998, GB/T 15470.3-2025 and the following terms and for the purposes of this document, the definitions apply.
ISO and IEC maintain terminology databases used for standardization at the following addresses.
3.101
radiant factor
The ratio of the measured infrared heat output to the measured total energy input, expressed in %.
Note. The emissivity of plate heaters, convection heaters and radiant heaters can be measured.
3.102
Radiation efficiency the heat flowing into the (test) chamber through radiation exchange between the effective radiation heating surface and the inner surface of the chamber is equal to the heat of the heater in the test chamber.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 15470.3-2025Household electric direct-acting room heaters - Methods for measuring performance - Part 3: Additional provisions for the measurement of the radiation efficiency
- GB/T 15470-2002Household electric direct-acting room heaters - Methods for measuring performance - Part 1: General provisions
IEC 60675
How to Download GB/T 15470.2-2025
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 15470-2002 — Household electric direct-acting room heaters - Methods for measuring performance - Part 1: General provisions
GB/T 15470.3-2025 — Household electric direct-acting room heaters - Methods for measuring performance - Part 3: Additional provisions for the measurement of the radiation efficiency
GB/T 15470.1-2026 — Household electric direct-acting room heaters - Methods for measuring performance - Part 1: General provisions
Secure payment via Stripe
Payments accepted
GB/T 15470.2-2025
$360.00