Valid

GB/T 15175-2012Measurement methods for main parameter of solid state lasers (English PDF)

固体激光器主要参数测量方法

Open the GB/T 15175-2012 preview as PDF

Preview — first pages of GB/T 15175-2012 (full document: 25 pages)

This is a limited preview

Buy now to download the full PDF (25 pages)

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China

Level / Type

National · Recommended

Issue date

December 31, 2012

Implementation date

June 1, 2013

Scope

GB/T 15175-2012 is the English-translated version of 固体激光器主要参数测量方法.

GB/T 15175-2012 is the Chinese national standard on measurement methods for main parameter of solid state lasers, in the field of electronics. The /T suffix marks it as a recommended standard: it is not compulsory by itself, but it becomes binding as soon as a contract, a tender or a customer specification calls it up - which in practice is how most foreign buyers meet it. It was issued on 31 December 2012 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 June 2013. Classification: ICS 31.260, CCS L51. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.

Document preview — GB/T 15175-2012

National Standard of the People's Republic of China

ICS
31.260
Classification
L51

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China

Contents

  • 1 Scope1
  • 2 Normative references1
  • 3 Terms, definitions and symbols 14
  • 4.1 Measurement Condition2
  • 4.2 measurement apparatus2
  • 4.3 Security2
  • 4.4 test laser2
  • 4.5 Preparation for measurement 2 5 main parameters of the laser measurement method2
  • 5.1 peak wavelength of2
  • 5.2 Continuous Power3
  • 5.3 Pulse repetition frequency4
  • 5 Pulse width 5.56
  • 5.6 Peak power6
  • 5.7 beam width or beam diameter of6
  • 5.8 beam divergence angle of10
  • 5.9 beam quality11
  • 5.10 output instability13
  • 5.11 degree of polarization14
  • 20 Annex C (informative) Derivation object space beam waist diameter is calculated21

Foreword

This standard rule according to GB/T 1.1-2009 given draft. This standard replaces GB/T 15175-1994 "solid-state lasers main parameters of the test method." This standard and GB/T 15175-1994 compared to the main changes are as follows:

--- Quoted in Chapter 3 GB/T 15313, delete the original standard and GB/T 15313 the same content of terms and definitions;

--- Chapter 4 adds provisions "arbitration measure atmospheric conditions";

--- Delete the original standard "transverse mode mode" measuring method (see 1994 edition 5.3);

--- In the "beam width or beam diameter" measurement method increases the measurement "hollow probe method" (see 5.7);

--- Increase "beam quality" measurement methods (see 5.9);

--- States that the "degree of polarization" specific content measurement method, delete the original standard GB/T 7257 "helium-neon laser parameters tested party Law "reference (see 5.11);

--- Added Appendix A, Appendix B and Appendix C. The standard proposed by the Ministry of Industry and Information Technology of the People's Republic of China. The standard by the China Electronics Standardization Institute. This standard was drafted. China Electronics Standardization Institute. The main drafters. Zhang Peng, Chen Lan. This standard replaces the standards previously issued as follows:

--- GB/T 15175-1994. The main parameters of solid-state laser measurement method

1 Scope

GB/T 15175-2012 is the Chinese national standard on measurement methods for main parameter of solid state lasers, in the field of electronics. The /T suffix marks it as a recommended standard: it is not compulsory by itself, but it becomes binding as soon as a contract, a tender or a customer specification calls it up - which in practice is how most foreign buyers meet it. It was issued on 31 December 2012 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 June 2013. Classification: ICS 31.260, CCS L51. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.

This standard specifies the method for measuring the main parameters of solid-state lasers. The main measurement standard applies to solid-state lasers (hereinafter referred to as "laser") parameters.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated edition applies to this article Member. For undated references, the latest edition (including any amendments) applies to this document. Safety - Part 1

GB 7247.1 laser products. Equipment classification, requirements GB/T 15313 Laser term

3 Terms, definitions and symbols

GB/T 15313 and established the following terms and definitions apply to this document.

3.1 Operating current operatingcurrents When the laser is operating, the pump source operating current.

3.2 Working conditions operatingconditions Laser operating conditions refer to its operating mode and the operating wavelength and other conditions.

3.3 Output instability

3.3.1 Output power instability outputpowerinstability SP Output power within a predetermined time interval fluctuate over time characteristics when the laser is operating properly.

3.3.2 Output energy instability outputenergyinstability SQ Energy output within the specified time intervals fluctuate over time characteristics when the laser is operating properly.

3.4 The maximum beam offset beammaximalexcursion Deltathetamax Within a certain time frame, the maximum angle of deviation from the center of the beam spot of the optical axis.

3.5 Repeat pulse average power output repetitionpulseoutputaveragepower Repeat pulse laser under specified operating conditions, over a period of time of the n-times the average output power measurement.

5 Pulse width 5.5

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 25 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB/T 15175

EditionTitleRevisionStatus
GB/T 15175-2012Measurement methods for main parameter of solid state laserscurrent editionCurrent
GB/T 15175-1994Measurement methods for main parameter of solid - State lasersprevious editionSuperseded

This page sells the current edition, GB/T 15175-2012. Earlier editions are listed for reference only.

How to Buy GB/T 15175-2012

  1. 1Add to cart. Click the "Buy GB/T 15175-2012" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
25 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 15175-2012

$380.00

$325.00for partners