Valid

GB/T 15072.19-2008Test method of precious metal alloys - Determination of vanadium and magnesium contents for silver alloys - Inductively coupled plasma atomic emission spectrometry (English PDF)

贵金属合金化学分析方法 银合金中钒和镁量的测定 电感耦合等离子体原子发射光谱法

Open the GB/T 15072.19-2008 preview as PDF

Preview — first pages of GB/T 15072.19-2008 (full document: 8 pages)

This is a limited preview

Buy now to download the full PDF (8 pages)

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China

Level / Type

National · Recommended

Issue date

March 31, 2008

Implementation date

September 1, 2008

Scope

GB/T 15072.19-2008 is the English-translated version of 贵金属合金化学分析方法 银合金中钒和镁量的测定 电感耦合等离子体原子发射光谱法.

GB/T 15072.19-2008 is the Chinese national standard on test method of precious metal alloys - determination of vanadium and magnesium contents for silver alloys - inductively coupled plasma atomic emission spectrometry, in the field of metallurgy. The /T suffix marks it as a recommended standard: it is not compulsory by itself, but it becomes binding as soon as a contract, a tender or a customer specification calls it up - which in practice is how most foreign buyers meet it. It was issued on 31 March 2008 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 September 2008. Classification: ICS 77.120.99, CCS H68. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.

Document preview — GB/T 15072.19-2008

National Standard of the People's Republic of China

ICS
77.120.99
Classification
H68

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Method summary
  • 4 Reagents and materials
  • 5 Instruments

Foreword

This standard is GB/T 15072-1994 "precious metals and their alloys -" (all parts) the integration of amendments into Part 19. Determination

--- GB/T 15072.1-2008 Methods for chemical analysis of precious metal alloys of gold, platinum, palladium, gold alloy amount of ferrous sulfate Potentiometric titration;

--- GB/T 15072.2-2008 Methods for chemical analysis of precious metal alloys silver alloys Determination of silver content of sodium chloride potential drop Titration;

--- GB/T 15072.3-2008 Methods for chemical analysis of precious metal alloys of gold, platinum, palladium, platinum alloys determining the amount of potassium permanganate Current titration;

--- GB /15072.4-2008 Methods for chemical analysis of precious metal alloys of palladium, silver-palladium alloy determining the amount of T-dimethyl glyoxal Gravimetric method;

--- GB/T 15072.5-2008 Methods for chemical analysis of precious metal alloys of gold, measuring the potential of potassium iodide palladium alloy of silver content drops Titration;

--- GB/T 15072.6-2008 precious metal alloys - Determination of platinum, palladium, iridium alloy in determining the amount of ferrous sulfate Current titration;

--- GB/T 15072.7-2008 precious metal alloys - Gold alloys chromium and iron content - Inductively coupled plasma Plasma atomic emission spectrometry;

--- GB/T 15072.8-2008 precious metal alloys - gold, palladium, silver and copper alloys - Determination of the amount of precipitation thiourea EDTA complexometric back titration;

--- GB/T 15072.9-2008 precious metal alloys - Gold alloys - Determination of the amount of indium by EDTA back drop Titration;

--- GB/T 15072.10-2008 precious metal alloys - Gold alloys - Determination of nickel by EDTA back drop Titration;

--- GB/T 15072.11-2008 precious metal alloys - gold alloy of gadolinium and beryllium content - Inductively coupled plasma Plasma atomic emission spectrometry;

--- GB T 15072.12-2008 precious metal alloys - Silver alloys - Determination of vanadium content/hydrogen peroxide spectrophotometer Law degree;

--- GB/T 15072.13-2008 precious metal alloys - Tin in silver, cerium and lanthanum content - Inductively coupled Plasma atomic emission spectrometry;

1 Scope

GB/T 15072.19-2008 is the Chinese national standard on test method of precious metal alloys - determination of vanadium and magnesium contents for silver alloys - inductively coupled plasma atomic emission spectrometry, in the field of metallurgy. The /T suffix marks it as a recommended standard: it is not compulsory by itself, but it becomes binding as soon as a contract, a tender or a customer specification calls it up - which in practice is how most foreign buyers meet it. It was issued on 31 March 2008 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 September 2008. Classification: ICS 77.120.99, CCS H68. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.

This section provides the determination of silver alloy of vanadium and magnesium content. This section applies to the determination AgCuV and AgMgNi alloy vanadium and magnesium content, the measurement range (mass fraction). 0.05% to 1%.

2 Normative references

The following documents contain provisions which, through reference in this text, constitute provisions of this part. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this section, however, encourage the parties to this part of the research agreement Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this section. 371 precious metal alloys - General rules and regulations YS/T

3 Method summary

Sample dissolved in nitric acid, hydrochloric acid precipitation of silver chloride formed was isolated by filtration silver, inductively coupled plasma atomic emission spectrometry (hereinafter Acronym ICP-AES) was measured to calculate the mass fraction of vanadium and magnesium.

4 Reagents and materials

Unless otherwise indicated, this part of the reagents and materials shall comply with the provisions of YS/T 371's.

4.1 Argon ((Ar) >=99.95%).

4.2 hydrochloride (rho1.19g/mL). Nitrate 4.3 (rho1.42g/mL). Hydrochloride 4.4 (1 + 9).

4.5 V stock standard solution. Weigh 0.1000g vanadium ((V) >=99.99%), placed in 200mL beaker, add 5mL hydrochloric acid (4.2), cover the surface of the pan, over low heat until dissolved completely. Cooled to room temperature, moved with hydrochloric acid (4.4) 100mL volumetric flask and dilute to Scale. Mix well. 1mL solution containing 1mg vanadium.

4.6 Magnesium stock standard solution. Weigh 0.3469g magnesium carbonate ((MgCO3) >=99.95%, advance after 1000 °C burning 1h, placed Desiccator, cool to room temperature), placed in 200mL beaker. 5mL of water was added, 3mL hydrochloric acid was added slowly (4.2), covered with a watch glass, Warmed to completely dissolve the reaction to be slowed. Cooled to room temperature, moved with hydrochloric acid (4.4) 100mL volumetric flask and dilute to volume. mix uniform. This solution 1mL 1mg containing magnesium.

5 Instruments

ICP-AES instrument. Under optimum working conditions for those who can reach the following indicators can be used.

5.1 source. argon plasma light source, the generator is not less than the maximum output power of 1.3kW.

5.2 Resolution. Optical resolution of about 200nm is not more than 0.010nm; Optical resolution of about 400nm, there is little To 0.020nm.

5.3 Instrument stability. stability within the instrument 1h (RSD) less than 2.0%.

5.4 The detection limit of the spectrometer. white liquid detection limit of vanadium and magnesium was no more than 0.05mg/L.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 8 pages — is available in the English PDF.

Similar standards

Editions of GB/T 15072.19

EditionTitleRevisionStatus
GB/T 15072.19-2008Test method of precious metal alloys - Determination of vanadium and magnesium contents for silver alloys - Inductively coupled plasma atomic emission spectrometrycurrent editionCurrent

This page sells the current edition, GB/T 15072.19-2008. Earlier editions are listed for reference only.

How to Buy GB/T 15072.19-2008

  1. 1Add to cart. Click the "Buy GB/T 15072.19-2008" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
8 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 15072.19-2008

$80.00

$70.00for partners