Valid

GB/T 1408.3-2016Insulating materials -- Test methods for electric strength -- Part 3: Additional requirements for 1.2/50µs impulse tests (English PDF)

Preview PDF

Also coversGBT1408.3-2016

This is a limited preview

Buy now to download the full PDF (10 pages)

Need quotation for your management?

Get a formal quotation for GB/T 1408.3-2016 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Recommended

Issue date

December 13, 2016

Implementation date

July 1, 2017

Scope

GB/T 1408.3-2016 (Insulating materials -- Test methods for electric strength -- Part 3: Additional requirements for 1.2/50µs impulse tests) is available as an English-translated PDF.

GB/T 1408.3-2016 - This Part of GB/T 1408 gives requirements additional to those in GB/T 1408.1 for the determination of the electric strength of solid insulating materials under 1.2/50µs impulse voltage stress.

Found what you need?

Document preview — GB/T 1408.3-2016

National Standard of the People's Republic of China

ICS
29.035.99
Classification
K 15

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Foreword...3
  • 1 Scope...5
  • 2 Normative References...5
  • 3 Terms and Definitions...5
  • 4 Significance of the Test...6
  • 5 Electrodes and Test Specimens...7
  • 6 Conditioning before Tests...7
  • 7 Surrounding Medium...7
  • 8 Electrical Apparatus...8
  • 9 Procedure...8
  • 10 Application of Voltage...8
  • 11 Criterion of Breakdown...9
  • 12 Number of Tests...9
  • 13 Report...10

Foreword

GB/T 1408 Electrical Strength of Insulating Materials - Test Methods consists of the following

3 parts:

--- Part 1: Tests at Power Frequencies;

--- Part 2: Additional Requirements for Tests Using Direct Voltage;

--- Part 3: Additional Requirements for 1.2/50µs Impulse Tests.

This Part is Part 3 of GB/T 1408.

This Standard was drafted as per the rules specified in GB/T 1.1-2009.

This Part replaced GB/T 1408.3-2007 Electric Strength of Insulating Materials Test Methods -

Part 3: Additional Requirements for 1.2/50µs Impulse Tests. Compared with GB/T 1408.3-2007,

the major technical changes of this Part are as follows:

--- Modify GB/T 1408.1-2006 into "GB/T 1408.1-2016" in the whole text;

--- Modify "pulse" into "impulse" in the whole text;

--- Change the term "virtual" to "apparent" (see 3.3~3.6 of this Edition; 3.3~3.6 of the 2007

Edition);

--- Add the terms "impulse breakdown voltage" and "withstand voltage" (see 3.7 and 3.8 of

this Edition);

--- Modify "report content".

This Part uses translation method to equivalently adopt IEC 60243-3:2013 Electric Strength of

Insulating Materials – Test Methods – Part 3: Additional Requirements for 1.2/50µs Impulse

Tests (The 3rd Version).

This Part was proposed by China Electrical Equipment Industry Association.

This Part shall be under the jurisdiction of National Technical Committee on Electrical

Insulating Materials and Insulating System Evaluation of Standardization Administration of

China (SAC/TC 301).

Drafting organizations of this Part: Machinery Industry Beijing Electrotechnical Institute of

Economic Research; Jiaxing New World Electromechanical Co., Ltd.; Foshan Shunde Quality

and Technical Supervision Standards and Coding Institute; Guilin Electrical Equipment

Scientific Research Institute Co., Ltd.; and Beijing BEIZHONG Stem Turbine Generator Co.,

Ltd.

Insulating Materials – Test Methods for Electric Strength –

Part 3: Additional Requirements for 1.2/50µs Impulse Tests

1 Scope

This Part of GB/T 1408 gives requirements additional to those in GB/T 1408.1 for the

determination of the electric strength of solid insulating materials under 1.2/50µs impulse

voltage stress.

2 Normative References

The following documents are essential to the application of this Document. For the dated

documents, only the versions with the dates indicated are applicable to this Document; for the

undated documents, only the latest version (including all the amendments) is applicable to this

Document.

GB/T 1408.1-2016 Electrical strength of insulating materials - Test methods - Part 1: Tests

at power frequencies (IEC 60243-1:2013, IDT)

3 Terms and Definitions

For the purposes of this Document, the terms and definitions given in GB/T 1408.1-2016 apply.

3.1 Full impulse-voltage wave

Aperiodic transient voltage that rises rapidly to a maximum value, then falls less rapidly to zero

(see Figure 1).

3.2 Peak value (of an impulse-voltage wave); UP

Maximum value of voltage.

3.3 Virtual peak value of an impulse-voltage wave; U1

Value derived from a recording of an impulse-voltage wave on which high-frequency

oscillations, or overshoot of a limited magnitude, may be present.

3.4 Virtual origin of an impulse-voltage wave; O1

peak voltages. The peak voltage of the initial set should be approximately 70 % of the expected

breakdown voltage.

Increase the peak voltage of successive sets by 5 % ~ 10 % of the peak value of the first set.

Table 1 of GB/T 1408.1-2016 is applicable.

Allow sufficient time between successive impulses for the generator to become completely

charged. Normally, a time of three times the charging time constant for the generator is

sufficient.

Sufficient time shall also be allowed between successive impulses to allow dissipation of any

injected space-charge. For many materials, the charging time of the generator will cover this

eventuality. For materials having a longer space-charge retention time, the necessary time shall

be specified in the material specification sheet. If this information is not known, but a long

space-charge retention period is suspected, then additional tests should be run with longer

intervals between impulses, to determine if a significant difference in breakdown values is

obtained.

A valid test on a test specimen is one in which impulse waves are applied at least two voltage

levels without breakdown, before breakdown occurs at the third or a subsequent level.

The electric strength shall be based on the virtual peak voltage of the last set of three waves

which was applied without breakdown. The breakdown voltage is the nominal voltage of the

next set of waves causing breakdown.

When using asymmetrical electrode systems, preliminary tests shall be conducted to determine

the polarity which yields the lower breakdown voltage. If significant differences are obtained,

the polarity giving the lower test results should be used.

10.2 Proof tests

One set of three impulses of specified proof voltage (virtual value) shall be applied to the test

specimen in accordance with Clause 11 of GB/T 1408.1-2016. When necessary for calibration

purposes, up to three impulses with peak voltages not exceeding 80 % of the proof voltage may

be applied prior to the application of the proof voltage waves.

11 Criterion of Breakdown

Clause 11 of GB/T 1408.1-2016 is applicable.

12 Number of Tests

Clause 12 of GB/T 1408.1-2016 is applicable.

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 1408.3-2016

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
10 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 1408.3-2016

$130.00