GB/T 1408.2-2016Insulating materials -- Test methods for electric strength -- Part 2: Additional requirements for tests using direct voltage (English PDF)

Preview PDF

Also coversGBT1408.2-2016

This is a limited preview

Buy now to download the full PDF (9 pages)

Need quotation for your management?

Get a formal quotation for GB/T 1408.2-2016 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Recommended

Issue date

December 13, 2016

Implementation date

July 1, 2017

Scope

GB/T 1408.2-2016 (Insulating materials -- Test methods for electric strength -- Part 2: Additional requirements for tests using direct voltage) is available as an English-translated PDF.

GB/T 1408.2-2016 — This Part of GB/T 1408 gives requirements additional to those in GB/T 1408.1 for the determination of the electric strength of solid insulating materials under direct voltage stress.

Found what you need?

Document preview — GB/T 1408.2-2016

National Standard of the People's Republic of China

ICS
29.035.99
Classification
K 15

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Foreword...3
  • 1 Scope...5
  • 2 Normative References...5
  • 3 Terms and Definitions...5
  • 4 Significance of the Test...5
  • 5 Electrodes and Test Specimens...6
  • 6 Conditioning before Tests...6
  • 7 Surrounding Medium...6
  • 8 Electrical Apparatus...6
  • 9 Procedure...7
  • 10 Mode of Increase of Voltage...7
  • 11 Criterion of Breakdown...8
  • 12 Number of Tests...8
  • 13 Report...8
  • Bibliography...9

Foreword

GB/T 1408 Electrical Strength of Insulating Materials - Test Methods consists of the following

3 parts:

--- Part 1: Tests at Power Frequencies;

--- Part 2: Additional Requirements for Tests Using Direct Voltage;

--- Part 3: Additional Requirements for 1.2/50µs Impulse Tests.

This Part is Part 2 of GB/T 1408.

This Standard was drafted as per the rules specified in GB/T 1.1-2009.

This Part replaced GB/T 1408.2-2006 Electrical Strength of Insulating Materials - Test Methods

- Part 2: Additional Requirements for Tests Using Direct Voltage. Compared with GB/T 1408.2-

2006, the major technical changes of this Part are as follows:

--- Modify GB/T 1408.1-2006 INTO "GB/T 1408.1-2016" in the whole text;

--- Delete 10 reference documents including GB/T 1981.2-2003;

--- Modify the report content;

--- Add Bibliography.

This Part uses translation method to equivalently adopt IEC 60243-2:2013 Electric Strength of

Insulating Materials – Test Methods – Part 2: Additional Requirements for Tests Using Direct

Voltage (The 3rd Version).

This Part was proposed by China Electrical Equipment Industry Association.

This Part shall be under the jurisdiction of National Technical Committee on Electrical

Insulating Materials and Insulating System Evaluation of Standardization Administration of

China (SAC/TC 301).

Drafting organizations of this Part: Suzhou Taihu Electric Advanced Material Co., Ltd.;

Machinery Industry Beijing Electrotechnical Institute of Economic Research; Shanghai Electric

Cable Research Institute; Guilin Electrical Equipment Scientific Research Institute Co., Ltd.;

and Sichuan EM Technology Co., Ltd.

Chief drafting staffs of this Part: Liu Yali, Zhang Chunqi, Xia Junfeng, Xia Zhifeng, Wu Bin,

Cheng Hao, Wang Xianfeng, Zhao Ping, and Li Jiexia.

The historical edition replaced by this Part is as follows:

Insulating Materials – Test Methods for Electric Strength –

Part 2: Additional Requirements for Tests Using Direct Voltage

1 Scope

This Part of GB/T 1408 gives requirements additional to those in GB/T 1408.1 for the

determination of the electric strength of solid insulating materials under direct voltage stress.

2 Normative References

The following documents are essential to the application of this Document. For the dated

documents, only the versions with the dates indicated are applicable to this Document; for the

undated documents, only the latest version (including all the amendments) is applicable to this

Document.

GB/T 1408.1-2016 Electrical strength of insulating materials - Test methods - Part 1: Tests

at power frequencies (IEC 60243-1:2013, IDT)

3 Terms and Definitions

For the purposes of this Document, the terms and definitions given in GB/T 1408.1-2016 apply.

4 Significance of the Test

In addition to the requirements of Clause 4 of GB/T 1408.1-2016, the following points shall be

considered when using direct-voltage tests.

For a non-homogeneous test specimen, with alternating voltage, the distribution of voltage

stress within the test specimen is determined by impedance (largely capacitive). With an

increasing direct voltage, the voltage distribution may still be largely capacitive but depends

partly on the rate of voltage increase. The resistive voltage distribution, after constant voltage

application, represents the steady-state condition. The choice between direct or alternating

voltage depends upon the purpose for which the breakdown test is to be used and, to some

extent, on the intended application of the material.

Upon direct voltage application, the following currents result: the capacitive current, the electric

transients in initiating premature breakdowns.

The controls on voltage shall be capable of varying the test voltage smoothly and uniformly

between zero and the maximum test voltage and with the requested rate of voltage rise. The

rate of voltage rise shall be controllable within ±20 % of the specified rate. Steps in voltage rise

shall not exceed 2 % of the expected breakdown voltage value. Controls which automatically

increase the voltage at a selectable rate are preferable.

A current-sensitive interrupting device shall be used for switching off the direct voltage source.

For many materials, a dangerous voltage may persist across the test specimen for a considerable

time after the d.c. test voltage is removed. Disconnection of the power supply to the direct

voltage source does not necessarily result in the output voltage or the voltage at the electrodes

being reduced to zero. For this reason, it is essential that the electrodes be short-circuited and

connected to earth for a period equal to minimum twice the total charging time to ensure that

the charge is dissipated. For some large test specimens, it will be necessary to maintain the

shorted condition for 1 h or even longer.

A current-limiting resistance shall be used in series with the test specimen to prevent damage

to the high-voltage supply and to limit as far as possible the damage to the electrodes on the

test specimen when breakdown takes place. The maximum current permitted will depend on

the material under test and on the amount of damage to the electrodes which can be tolerated.

NOTE 1: The use of a very high-valued resistor may result in breakdown voltages which are higher than

those obtained with a lower-valued resistor.

When making tests where the value or increase in the value of the current is used as a criterion

for breakdown, means of measurement of current through the test specimen shall be provided.

8.2 Voltage Measurement

The measurement of applied voltage shall be made across the electrodes. The other

requirements of Clause 8 of GB/T 1408.1-2016 shall be met.

9 Procedure

Clause 9 of GB/T 1408.1-2016 is applicable.

10 Mode of Increase of Voltage

Unless otherwise specified, the voltage shall be applied in accordance with 10.1 (short-time

test), 10.3 or 10.5 (slow and very slow rate-of-rise tests) or 10.6 (proof tests) of GB/T 1408.1-

2016.

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 1408.2-2016

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
9 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 1408.2-2016

$70.00