GB/T 14048.19-2013Low-voltage switchgear and controlgear -- Part 5-7: Control circuit devices and switching elements -- Requirements for proximity devices with analogue output (English PDF)

Also coversGBT14048.19-2013

Open the GB/T 14048.19-2013 preview as PDF

Preview — first pages of GB/T 14048.19-2013

This is a limited preview

Buy now to download the full PDF

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Level / Type

National · Recommended

Issue date

December 17, 2013

Implementation date

April 9, 2014

Scope

GB/T 14048.19-2013 (Low-voltage switchgear and controlgear -- Part 5-7: Control circuit devices and switching elements -- Requirements for proximity devices with analogue output) is available as an English-translated PDF.

GB/T 14048.19-2013 — This section specifies the requirements for access to the equipment with analog outputs. The device may be one or multiple sections. This section applies to access to the equipment with analog outputs. GB/T 14048.10 (proximity switch) is carried out according to the requirements of the provisions of this section After the additions or modifications to it. Terms of this part number according to GB/T 14048.10 in terms of number of sequence numbers needed to make appropriate changes.

Document preview — GB/T 14048.19-2013

National Standard of the People's Republic of China

ICS
29.130.20
Classification
K 32

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Contents

  • Foreword
  • Introduction
  • 1 Basic Requirements
  • 1.1 Scope and purpose
  • 1.2 Normative references
  • 2 Terms and definitions
  • 2.1 Basic Definitions
  • 2.3 access to the equipment operation

Foreword

GB 14048 "Low-voltage switchgear and control equipment" is currently divided into 21 sections.

--- GB 14048.1 low-voltage switchgear and control equipment Part 1. General;

--- GB 14048.2 low-voltage switchgear and control equipment Part 2. Circuit Breaker;

--- GB 14048.3 low-voltage switchgear and control equipment - Part 3. Switches, disconnectors, switch and fuse combination

Appliances;

--- GB 14048.4 low-voltage switchgear and control equipment - Part 4-1. Contactors and motor starters Electromechanical contactors

And motor starters (including motor protection);

--- GB 14048.5 low-voltage switchgear and control equipment Part 5-1. Control circuit devices and switching elements - Electromechanical control

Electrical circuit;

--- GB 14048.6 low-voltage switchgear and control equipment Part 4-2. Contactors and motor starters - AC semiconductor

Motor controllers and starters (including soft starter);

--- GB/T 14048.7 low-voltage switchgear and control equipment Part 7-1. Ancillary copper conductor terminal blocks;

--- GB/T 14048.8 low-voltage switchgear and control equipment Part 7-2. Protection of the auxiliary conductor wiring copper conductors

Terminal block;

--- GB 14048.9 low-voltage switchgear and control equipment Part 6-2. Multiple function equipment (equipment) control and protection switch

Electric (equipment) (CPS);

--- GB/T 14048.10 voltage switchgear and control equipment Part 5-2. Control circuit devices and switching elements proximity

switch;

--- GB/T 14048.11 voltage switchgear and control equipment Part 6-1. Multiple function equipment - Transfer switching equipment;

--- GB/T 14048.12 voltage switchgear and control equipment Part 4-3. Contactors and motor starters - Non-Motor

Load AC semiconductor controllers and contactors;

--- GB/T 14048.13 voltage switchgear and control equipment Part 5-3. Control circuit devices and switching elements - Fault

Proximity Switch (PDF) to determine the conditions required to have the function;

--- GB/T 14048.14 voltage switchgear and control equipment Part 5-5. Control circuit devices and switching elements - with a machine

Mechanical latching function electrical emergency braking device;

--- GB/T 14048.15 voltage switchgear and control equipment Part 5-6. Control circuit devices and switching elements - proximity Biography

Sensors and switching amplifiers DC Interface (NAMUR);

--- GB/T 14048.16 voltage switchgear and control equipment - Part 8. rotary motor control with built - in thermal protection (PTC)

Unit;

--- GB/T 14048.17 voltage switchgear and control equipment Part 5-4. Control circuit devices and switching elements of small capacity

The method of evaluating the performance of special test contacts;

--- GB/T 14048.18 voltage switchgear and control equipment Part 7-3. Ancillary safety fuse terminal blocks

Wide requirements;

--- GB/T 14048.19 voltage switchgear and control equipment Part 5-7. Control circuit devices and switching elements for band

Analog output proximity equipment requirements;

--- GB/T 14048.20 voltage switchgear and control equipment Part 5-8. Control circuit devices and switching elements make three

You can switch;

--- GB/T 14048.21 voltage switchgear and control equipment Part 5-9. Control circuit devices and switching elements flow

switch.

This section GB 14048 "Low-voltage switchgear and control equipment" in Section 19.

This section drafted in accordance with GB/T 1.1-2009 given rules.

This section uses the translation method identical with IEC 60947-5-7.2003 "low-voltage switchgear and control equipment Part 5-7. control circuit

Road devices and switching elements for proximity devices requirements "with analog outputs.

This part is proposed by the China Electrical Equipment Industrial Association.

The low-voltage electrical part by the National Standardization Technical Committee (SAC/TC189) centralized.

This section is responsible for drafting unit. Shanghai Electric Apparatus Research Institute, Shanghai Electric Technology Co., Ltd. Electric Division.

Participated in the drafting of this section. Suzhou Institute of Electric Co., Ltd. JU Bang Electric Co., Ltd., Shanghai Electric Equipment Unit

The measured.

Introduction

This section modifies the GB/T 14048.10-2008 the requirements for proximity switches with semiconductor switching element to apply to DYMO

It intends to export close to equipment.

Low-voltage switchgear and control equipment

Part 5-7. Control circuit devices and switching elements

Requirements for proximity devices with analogue output of

1 Basic Requirements

1.1 Scope and purpose

This section specifies the requirements for access to the equipment with analog outputs. The device may be one or multiple sections.

This section applies to access to the equipment with analog outputs. GB/T 14048.10 (proximity switch) is carried out according to the requirements of the provisions of this section

After the additions or modifications to it. Terms of this part number according to GB/T 14048.10 in terms of number of sequence numbers needed to make appropriate changes.

1.2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein

Member. For undated references, the latest edition (including any amendments) applies to this document.

GB/T 14048.10-2008 voltage switchgear and control equipment Part 5-2. Control circuit devices and switching elements proximity

Switches (IEC 60947-5-2.2004, IDT)

2 Terms and definitions

Terms and Definitions The following terms and definitions GB/T 14048.10-2008 defined apply to this document.

2.1 Basic Definitions

2.1.2

Proximity devices with analog outputs proximitydevicewithanalogueoutput

According to the output signal from the sensing surface close to the device to its target object is continuously changed between the devices.

2.1.3

The lower limit distance lowerdistance

Predetermined minimum distance is greater than the value of the output signal changes continuously.

2.1.4

Ceiling distance upperdistance

Predetermined maximum distance, less than this value, the output signal changes continuously.

2.1.5

Distance distancerange

Distance from the lower limit and upper limit of the distance between, including the upper and lower limits.

2.3 access to the equipment operation

2.3.7

Close to the device from the I/O characteristic distance/outputcharacteristicoftheproximitydevice

Steady state, the output signal (current or voltage value) with respect to the distance between the surface and proximity sensor devices target object relationship.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

Referenced standards

Normative references

GB/T 14048.10-2008 · IEC 60947

How to Buy GB/T 14048.19-2013

  1. 1Add to cart. Click the "Buy GB/T 14048.19-2013" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 14048.19-2013

$200.00

$170.00for partners