Scope
GB/T 13747.2-2019 is the English-translated version of 锆及锆合金化学分析方法 第2部分:铁量的测定 1,10-二氮杂菲分光光度法和电感耦合等离子体原子发射光谱法.
GB/T 13747.2-2019, Part 2 of the Chinese series of methods for the chemical analysis of zirconium and zirconium alloys, specifies two methods for determining iron content in sponge zirconium, zirconium and zirconium alloys over the range 0.010% to 0.40%.
Method 1, the referee method, decomposes the sample with sulfuric acid-ammonium sulfate, complexes zirconium with citric acid, reduces iron with hydroxylamine hydrochloride and measures the red iron(II)-1,10-phenanthroline complex at 510 nm.
Method 2 dissolves the sample in hydrofluoric and nitric acids and measures iron by inductively coupled plasma atomic emission spectrometry at 238.20 nm against matrix-matched zirconium calibration solutions; both methods give reagents, apparatus, procedure, calculation formulas and repeatability and reproducibility limits, followed by the content of the test report.
It replaces GB/T 13747.2-1992: the range has been extended from 0.250% to 0.40%, the test portion mass, acidity adjustment and colour development (now 15 min in a 70 °C to 80 °C water bath) have been changed, and the ICP-AES method, a sample clause, precision data and a test report clause have been added.
Issued on 31 December 2019, in force since 1 November 2020. Classification: ICS 77.120.99, CCS H14. The document runs to 8 pages, delivered complete in English translation.
Found what you need?
Document preview — GB/T 13747.2-2019
National Standard of the People's Republic of China
- ICS
- 77.120.99
- Classification
- H14
- Replacing
- GB/T 13747.2-1992
Issued by: State Administration for Market Regulation; Standardization Administration of China
Contents
- ForewordI
- 1 Scope1
- 2 Method 1 - 1,10-phenanthroline spectrophotometry1
- 2.1 Principle1
- 2.2 Reagents1
- 2.3 Apparatus1
- 2.4 Sample1
- 2.5 Procedure2
- 2.5.1 Test portion2
- 2.5.2 Parallel determination2
- 2.5.3 Blank test2
- 2.5.4 Determination2
- 2.5.5 Preparation of the calibration curve2
- 2.6 Calculation and expression of results2
- 2.7 Precision3
- 2.7.1 Repeatability3
- 2.7.2 Reproducibility3
- 3 Method 2 - Inductively coupled plasma atomic emission spectrometry3
- 3.1 Principle3
- 3.2 Reagents3
- 3.3 Apparatus3
- 3.4 Sample4
- 3.5 Procedure4
- 3.5.1 Test portion4
- 3.5.2 Parallel determination4
- 3.5.3 Blank test4
- 3.5.4 Preparation of the test solution4
- 3.5.5 Preparation of the calibration solutions4
- 3.5.6 Determination4
- 3.6 Calculation and expression of results4
- 3.7 Precision5
- 3.7.1 Repeatability5
- 3.7.2 Reproducibility5
- 4 Test report5
Foreword
GB/T 13747, Methods for chemical analysis of zirconium and zirconium alloys, is planned to consist of 27 parts:
- Part 1: Determination of tin content - Potassium iodate titration method and phenylfluorone-polyethylene glycol octylphenyl ether spectrophotometry;
- Part 2: Determination of iron content - 1,10-phenanthroline spectrophotometry and inductively coupled plasma atomic emission spectrometry;
- Part 3: Determination of nickel content - Dimethylglyoxime spectrophotometry and inductively coupled plasma atomic emission spectrometry;
- Part 4: Determination of chromium content - Diphenylcarbazide spectrophotometry and inductively coupled plasma atomic emission spectrometry;
- Part 5: Determination of aluminium content - Chrome azurol S-tetradecylpyridinium chloride spectrophotometry;
- Part 6: Determination of copper content - 2,9-dimethyl-1,10-phenanthroline spectrophotometry;
- Part 7: Determination of manganese content - Potassium periodate spectrophotometry and inductively coupled plasma atomic emission spectrometry;
- Part 8: Determination of cobalt content - Nitroso-R salt spectrophotometry;
- Part 9: Determination of magnesium content - Flame atomic absorption spectrometry;
- Part 10: Determination of tungsten content - Thiocyanate spectrophotometry;
- Part 11: Determination of molybdenum content - Thiocyanate spectrophotometry;
- Part 12: Determination of silicon content - Molybdenum blue spectrophotometry;
- Part 13: Determination of lead content - Polarography;
- Part 14: Determination of uranium content - Polarography;
- Part 15: Determination of boron content - Curcumin spectrophotometry;
- Part 16: Determination of chlorine content - Silver chloride turbidimetry and ion-selective electrode method;
- Part 17: Determination of cadmium content - Polarography;
- Part 18: Determination of vanadium content - N-benzoyl-N-phenylhydroxylamine spectrophotometry;
- Part 19: Determination of titanium content - Diantipyrylmethane spectrophotometry and inductively coupled plasma atomic emission spectrometry;
- Part 20: Determination of hafnium content - Inductively coupled plasma atomic emission spectrometry;
- Part 21: Determination of hydrogen content - Inert gas fusion infrared absorption/thermal conductivity method;
- Part 22: Determination of oxygen and nitrogen content - Inert gas fusion infrared absorption/thermal conductivity method;
- Part 23: Determination of nitrogen content - Distillation separation-Nessler reagent spectrophotometry;
- Part 24: Determination of carbon content - High-frequency combustion infrared absorption method;
- Part 25: Determination of niobium content - 5-Br-PADAP spectrophotometry and inductively coupled plasma atomic emission spectrometry;
- Part 26: Determination of alloying and impurity elements - Inductively coupled plasma atomic emission spectrometry;
- Part 27: Determination of trace impurity elements - Inductively coupled plasma mass spectrometry.
This part is Part 2 of GB/T 13747.
This part was drafted in accordance with the rules given in GB/T 1.1-2009.
This part replaces GB/T 13747.2-1992, Methods for chemical analysis of zirconium and zirconium alloys - Determination of iron content by 1,10-phenanthroline spectrophotometry. Compared with GB/T 13747.2-1992, apart from editorial changes, the main technical changes are as follows:
- the determination range has been extended from 0.010% to 0.250% to 0.010% to 0.40% (see Clause 1; Clause 1 of the 1992 edition);
- the normative references have been deleted (see Clause 2 of the 1992 edition);
- a clause on the sample has been added (see 2.4);
- the mass of the test portion has been adjusted (see 2.5.1; 6.1 of the 1992 edition);
- the acidity adjustment of the test solution has been partly modified (see 2.5.4.2 and 2.5.4.3; 6.3.2 and 6.3.3 of the 1992 edition);
- colour development of iron has been changed from room temperature to heating for 15 min in a water bath at 70 °C to 80 °C (see 2.5.4.3; 6.3.4 of the 1992 edition);
- an inductively coupled plasma atomic emission spectrometry method has been added, with a determination range of 0.010% to 0.40% (see Clause 3);
- precision clauses have been added (see 2.7 and 3.7);
- a test report clause has been added (see Clause 4).
This part was proposed by the China Nonferrous Metals Industry Association.
This part is under the jurisdiction of the National Technical Committee on Nonferrous Metals of Standardization Administration of China (SAC/TC 243).
Drafting organizations of this part: Guangdong Industrial Analysis and Testing Center, Xi'an Hantang Analysis and Testing Co., Ltd., Western Metal Materials Co., Ltd., Baoti Group Co., Ltd., BGRIMM Testing Technology Co., Ltd., Western New Zirconium Nuclear Materials Technology Co., Ltd., and Jinduicheng Molybdenum Co., Ltd.
Drafters of this part: Xiong Xiaoyan, Mai Libi, Liu Biao, Wang Jin, Lu Ni, Zhou Kai, Zhang Bin, Zhao Wuli, Bai Huanhuan, Zhou Hang, Li Weimin, Li Fan, Hui Boning, Xie Mingming and Chai Yuqing.
The previous edition of the standard replaced by this part is:
- GB/T 13747.2-1992.
1 Scope
This part of GB/T 13747 specifies methods for the determination of iron content in zirconium and zirconium alloys.
This part applies to the determination of iron content in sponge zirconium, zirconium and zirconium alloys. Determination range: 0.010% to 0.40%. Method 1 is the referee method.
2 Method 1 - 1,10-phenanthroline spectrophotometry
2.1 Principle
The test portion is decomposed with sulfuric acid-ammonium sulfate, zirconium is complexed with citric acid, and Fe3+ is reduced to Fe2+ with hydroxylamine hydrochloride. At about pH 6, Fe2+ forms a red complex with 1,10-phenanthroline, whose absorbance is measured with a spectrophotometer at a wavelength of 510 nm.
2.2 Reagents
Unless otherwise stated, use only reagents of recognized analytical grade and grade 2 laboratory water.
2.2.1 Hydrochloric acid (1+1).
2.2.2 Ammonium sulfate.
2.2.3 Sulfuric acid (rho = 1.84 g/mL).
2.2.4 Hydroxylamine hydrochloride solution (100 g/L).
2.2.5 Citric acid solution (500 g/L).
2.2.6 Acetic acid-ammonium acetate buffer solution: dissolve 500 g of ammonium acetate in water, add 20 mL of glacial acetic acid, dilute to 1 000 mL with water and mix.
2.2.7 Ammonia solution (1+1).
2.2.8 1,10-phenanthroline solution (5 g/L): dissolve 0.5 g of 1,10-phenanthroline in 20 mL of absolute ethanol, dilute to 100 mL with water, mix and store in a brown bottle.
2.2.9 Iron standard stock solution: weigh 1.000 0 g of metallic iron (wFe >= 99.99%) into a 200 mL beaker, add 30 mL of hydrochloric acid (2.2.1) and heat gently until completely dissolved; cool, transfer to a 1 000 mL volumetric flask, dilute to the mark with water and mix. 1 mL of this solution contains 1 mg of iron.
2.2.10 Iron standard solution: pipette 10.00 mL of the iron standard stock solution (2.2.9) into a 100 mL volumetric flask, dilute to the mark with water and mix. 1 mL of this solution contains 100 µg of iron.
2.3 Apparatus
Spectrophotometer.
2.4 Sample
The sample shall be machined into chips not longer than 5 mm.
2.5 Procedure
2.5.1 Test portion
Weigh the sample (2.4) according to Table 1, to the nearest 0.000 1 g.
Table 1 - Mass of test portion: iron mass fraction 0.010% to 0.10%: test portion 1.00 g, total volume of test solution 100 mL, aliquot 20.00 mL; iron mass fraction >0.10% to 0.40%: test portion 0.50 g, total volume of test solution 100 mL, aliquot 10.00 mL.
2.5.2 Parallel determination
Carry out two determinations in parallel and take the mean value.
2.5.3 Blank test
Carry out a blank test together with the test portion. Where the iron mass fraction is not more than 0.1%, carry out two blank tests in parallel.
2.5.4 Determination
2.5.4.1 Place the test portion (2.5.1) in a 150 mL beaker, add 10 mL of sulfuric acid (2.2.3) and 5 g of ammonium sulfate (2.2.2), cover with a watch glass and decompose by heating on a high-temperature electric hotplate; continue heating until the separated sulfur has disappeared. Cool, transfer to a 100 mL volumetric flask, dilute to the mark with water and mix. Transfer an aliquot of the test solution, as given in Table 1, into a 100 mL volumetric flask.
2.5.4.2 Add 5 mL of citric acid solution (2.2.5) and 5 mL of hydroxylamine hydrochloride solution (2.2.4) and allow to stand for 10 min. Add a small piece of Congo red test paper and neutralize with ammonia solution (2.2.7) until the Congo red paper just turns from blue to purple.
2.5.4.3 Add 3 mL of acetic acid-ammonium acetate buffer solution (2.2.6) and 5 mL of 1,10-phenanthroline solution (2.2.8), heat in a water bath at 70 °C to 80 °C for 15 min, remove, cool to room temperature, dilute to the mark with water and mix.
2.5.4.4 Transfer part of the solution (2.5.4.3) into a 2 cm cell and, using the blank solution carried through with the test portion as reference, measure the absorbance with a spectrophotometer at a wavelength of 510 nm. Read the corresponding iron content from the calibration curve.
2.5.5 Preparation of the calibration curve
2.5.5.1 Pipette 0 mL, 0.20 mL, 0.50 mL, 1.00 mL, 1.50 mL, 2.00 mL and 2.50 mL of iron standard solution (2.2.10) into a series of 100 mL volumetric flasks, add to each a volume of blank test solution equal to the aliquot of test solution, and proceed as in 2.5.4.2 and 2.5.4.3.
2.5.5.2 Transfer part of each solution (2.5.5.1) into a 2 cm cell and, using the reagent blank solution as reference, measure the absorbance with a spectrophotometer at a wavelength of 510 nm. Plot the calibration curve with iron content as abscissa and absorbance as ordinate.
2.6 Calculation and expression of results
The iron content, expressed as the mass fraction of iron wFe, is calculated by formula (1):
wFe = (m1 × V0 × 10^-6) / (m0 × V1) × 100% ... (1)
where:
m1 - mass of iron read from the calibration curve, in micrograms (µg);
V0 - total volume of the test solution, in millilitres (mL);
m0 - mass of the test portion, in grams (g);
V1 - volume of the aliquot of test solution, in millilitres (mL).
The result is expressed to two significant figures.
2.7 Precision
2.7.1 Repeatability
The absolute difference between two independent test results obtained under repeatability conditions, within the range of mean values given in Table 2, shall not exceed the repeatability limit (r) in more than 5% of cases. The repeatability limit (r) is obtained from the data in Table 2 by linear interpolation or extrapolation.
Table 2 - Repeatability limits (Method 1): iron mass fraction 0.047%: r = 0.004%; 0.27%: r = 0.02%; 0.37%: r = 0.03%.
2.7.2 Reproducibility
The absolute difference between two independent test results obtained under reproducibility conditions, within the range of mean values given in Table 3, shall not exceed the reproducibility limit (R) in more than 5% of cases. The reproducibility limit (R) is obtained from the data in Table 3 by linear interpolation or extrapolation.
Table 3 - Reproducibility limits (Method 1): iron mass fraction 0.047%: R = 0.005%; 0.27%: R = 0.02%; 0.37%: R = 0.03%.
3 Method 2 - Inductively coupled plasma atomic emission spectrometry
3.1 Principle
The test portion is dissolved with nitric acid and hydrofluoric acid. The determination is made by inductively coupled plasma atomic emission spectrometry; the mass concentration of iron is calculated by the calibration curve method and the result is expressed as a mass fraction.
3.2 Reagents
Unless otherwise stated, use only reagents of recognized analytical grade and grade 2 laboratory water.
3.2.1 Hydrofluoric acid (rho = 1.13 g/mL).
3.2.2 Nitric acid (1+1).
3.2.3 Iron standard stock solution: weigh 1.000 0 g of metallic iron (wFe >= 99.99%) into a 250 mL beaker, dissolve with 20 mL of nitric acid (3.2.2) and cool. Transfer to a 1 000 mL volumetric flask, dilute to the mark with water and mix. 1 mL of this solution contains 1 mg of iron.
3.2.4 Iron standard solution: pipette 10.00 mL of the iron standard stock solution (3.2.3) into a 100 mL volumetric flask, add 2 mL of nitric acid (3.2.2), dilute to the mark with water and mix. 1 mL of this solution contains 100 µg of iron.
3.2.5 Zirconium metal (wZr >= 99.9%, wFe <= 0.001%).
3.2.6 Argon (volume fraction >= 99.99%).
3.3 Apparatus
Inductively coupled plasma atomic emission spectrometer with a hydrofluoric acid-resistant sample introduction system and a resolution better than 0.006 nm (at 200 nm).
3.4 Sample
The sample shall be machined into chips not longer than 5 mm.
3.5 Procedure
3.5.1 Test portion
Weigh 0.20 g of the sample (3.4), to the nearest 0.000 1 g.
3.5.2 Parallel determination
Carry out two determinations in parallel and take the mean value.
3.5.3 Blank test
Weigh 0.200 g of zirconium metal (3.2.5) and carry out a blank test together with the test portion.
3.5.4 Preparation of the test solution
Place the test portion (3.5.1) in a 150 mL polytetrafluoroethylene beaker, add 10 mL to 15 mL of water and 2 mL of hydrofluoric acid (3.2.1) to dissolve. When the reaction has ceased, add 2 mL of nitric acid (3.2.2) until the sample is completely dissolved, cool, transfer to a 100 mL plastic volumetric flask, dilute to the mark with water and mix.
3.5.5 Preparation of the calibration solutions
Weigh 0.200 g portions of pure zirconium (3.2.5) into a series of 150 mL polytetrafluoroethylene beakers and dissolve them as in 3.5.4. After cooling, transfer each into a 100 mL plastic volumetric flask, add respectively 0 mL, 0.20 mL, 0.50 mL, 2.00 mL, 5.00 mL and 10.00 mL of iron standard solution (3.2.4), dilute to the mark with water and mix.
3.5.6 Determination
3.5.6.1 Recommended analytical line wavelength: 238.20 nm.
3.5.6.2 On the inductively coupled plasma atomic emission spectrometer, at the selected analytical wavelength, measure the calibration solutions (3.5.5). When the linear correlation coefficient of the calibration curve k >= 0.999, measure the emission intensity of iron in the test solution (3.5.4) and in the blank solution (3.5.3), and read the mass concentration of the element from the calibration curve.
3.6 Calculation and expression of results
The iron content, expressed as the mass fraction of iron wFe, is calculated by formula (2):
wFe = ((rho1 - rho0) × V2 × 10^-6) / m × 100% ... (2)
where:
rho1 - mass concentration of iron in the test solution, in micrograms per millilitre (µg/mL);
rho0 - mass concentration of iron in the blank solution, in micrograms per millilitre (µg/mL);
V2 - volume of the test solution, in millilitres (mL);
m - mass of the test portion, in grams (g).
The result is expressed to two significant figures.
3.7 Precision
3.7.1 Repeatability
The absolute difference between two independent determination results obtained under repeatability conditions, within the range of mean values given in Table 4, shall not exceed the repeatability limit (r) in more than 5% of cases. The repeatability limit (r) is obtained from the data in Table 4 by linear interpolation or extrapolation.
Table 4 - Repeatability limits (Method 2): iron mass fraction 0.047%: r = 0.003%; 0.27%: r = 0.02%; 0.37%: r = 0.03%.
3.7.2 Reproducibility
The absolute difference between two independent determination results obtained under reproducibility conditions, within the range of mean values given in Table 5, shall not exceed the reproducibility limit (R) in more than 5% of cases. The reproducibility limit (R) is obtained from the data in Table 5 by linear interpolation or extrapolation.
Table 5 - Reproducibility limits (Method 2): iron mass fraction 0.047%: R = 0.006%; 0.27%: R = 0.02%; 0.37%: R = 0.03%.
4 Test report
The test report shall include the following:
- the test object;
- the number of this part;
- the method used;
- the results;
- any abnormal phenomena observed;
- the date of the test.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 8 pages — is available in the English PDF.
Similar standards
Editions of GB/T 13747.2
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 13747.2-2019 | Methods for chemical analysis of zirconium and zirconium alloys - Part 2: Determination of iron content - 1,10-phenanthroline spectrophotometry and inductively coupled plasma atomic emission spectrometry | current edition | Current |
| GB/T 13747.2-1992 | and zirconium alloys - Determination of iron content-1, 10-phenanthroline spectrophotometric method | previous edition | Superseded |
This page sells the current edition, GB/T 13747.2-2019. Earlier editions are listed for reference only.
How to Download GB/T 13747.2-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 13747.3-2020 — Methods for chemical analysis of zirconium and zirconium alloys-Part 3: Determination of nickel content-Dimethyglyoxime spectrophotometry and inductively coupled plasma atomic emission spectrometry