GB/T 12972.4-2008Flexible rubber-sheathed cables for mining purposes - Part 4: Flexible coalcutter cables with individual metallic screens for rated voltages up to 1.9/3.3kV (English PDF)
矿用橡套软电缆 第4部分:额定电压1.9/3.3kV及以下采煤机金属屏蔽软电缆
This is a limited preview
Buy now to download the full PDF (10 pages)
Need quotation for your management?
Get a formal quotation for GB/T 12972.4-2008 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China
Level / Type
National · Recommended
Issue date
June 30, 2008
Implementation date
April 1, 2009
Scope
GB/T 12972.4-2008 is the English-translated version of 矿用橡套软电缆 第4部分:额定电压1.9/3.3kV及以下采煤机金属屏蔽软电缆.
GB/T 12972.4-2008 is the fourth part of the Chinese national series on flexible rubber-sheathed mining cables, covering coal-cutter cables with individual metallic screens for rated voltages up to 1.9/3.3 kV.
Its summary states that it specifies the product varieties, technical requirements, test methods and inspection rules for these cables, that it applies to rubber-insulated, rubber-sheathed copper cables with metallic screens for shearers and similar machines at 1.9/3.3 kV and below, and that this part is to be used together with GB/T 12972.1-2008.
The cables are rated U0/U 0.66/1.14 kV and 1.9/3.3 kV, and the conductor has a long-term permissible working temperature of 90 °C. Its foreword records that UCPTJ-0.66/1.14 kV sizes were extended from 16-95 mm² to 16-120 mm² and that the burning test now follows GB/T 18380.1.
It replaces GB 12972.4-1991, was issued on 30 June 2008 and has applied since 1 April 2009.
Found what you need?
Document preview — GB/T 12972.4-2008
National Standard of the People's Republic of China
- ICS
- 29.060.20
- Classification
- K 13
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China
Contents
- Foreword
Foreword
GB/T 12972 "mining rubber flexible cable" is divided into 10 parts.
--- Part 1. General requirements;
--- Part 2. Rated voltage 1.9/3.3kV and below Shearer flexible cables;
--- Part 3. rated voltage of 0.66/1.14kV Shearer shielded monitor enhanced flexible cables;
--- Part 4. Rated voltage 1.9/3.3kV and below Shearer metal shield soft cable;
--- Part 5. rated voltage of 0.66/1.14kV and following mobile rubber soft cable;
--- Part 6. Rated voltage 6/10kV and below the metal shield Flexible cables with monitoring;
--- Part 7. rated voltage 6/10kV and below shielded rubber-sheathed cables;
--- Part 8. Rated voltage 0.3/0.5kV drill cables;
--- Part 9. Rated voltage 0.3/0.5kV light mine mobile rubber soft cable;
--- Part 10. Miner 's cap lamp cords. This section GB/T Part of 412,972.
This Part replaces GB 12972.4-1991 "mining rubber-sheathed cables - Part 4. rated voltage of 0.66/1.14kV Shearer metal Shielded flexible cable. " This section compared with GB 12972.4-1991 main changes are as follows.
--- Name changed to "rated voltage 1.9/3.3kV and below Shearer metal shield soft cable";
--- Increasing the rated voltage 1.9/3.3kV Shearer metal shield soft cable (Excerpts of Table 1);
--- Modify a monitoring line UCPT core structure is UCPTJ type (1991 edition Table 1; Table 1 edition);
--- UCPTJ-0.66/1.14kV cable specifications by the conductor cross-section 16mm² ~ 95mm² to 16mm² ~ 120mm² (1991 edition Table 2; Table 2 edition);
--- Increased UCPT-0.66/1.14kV cable content (Excerpts of Tables 1 and 2);
--- Increased UCPT-1.9/3.3kV cable content (Excerpts of Table 1 and Table 4);
--- Increased UCPTJ-1.9/3.3kV cable content (Excerpts of Table 1 and Table 5);
--- Remove the XJ-30A-type rubber content (1991 version 5.3.1);
--- Power core 35mm² and above the cable core stranding pitch ratio "is not more than 11" to "not more than 9" (1991 edition 5.4.3; 6.4 edition);
--- Remove the insulated core flooding frequency AC voltage test content (this version 5.2.3);
--- Increase the ground wire parallel to the shield 20 °C DC resistance Max (edition 7.1);
--- Cable burning test by the GB/T 18380.1 "cables under fire conditions test - Part 1. single insulated wire or Cable vertical burning test method "to replace the original GB 12666.2" single wire or cable vertical burning test method "(1991 edition Table 4; edition 7.3).
3 Use Characteristics
3.1
Rated voltage U0/U of 0.66/1.14kV and 1.9/3.3kV
3.2
Cable conductor long-term allowable working temperature of 90 °C
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.
Similar standards
Editions of GB/T 12972.4
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 12972.4-2008 | Flexible rubber-sheathed cables for mining purposes - Part 4: Flexible coalcutter cables with individual metallic screens for rated voltages up to 1.9/3.3kV | current edition | Current |
| GB 12972.4-1991 | Flexible rubber-sheathed cables for mining purposes-Part 4: Flexible coalcutter cables with indivdual metallic screens for rated voltage of 0.66/1.14kV | merged into this edition | Superseded |
This page sells the current edition, GB/T 12972.4-2008. Earlier editions are listed for reference only.
How to Download GB/T 12972.4-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 12972.5-2008 — Flexible rubber-sheathed cables for mining purposes - Part 5: Flexible cables for rated voltages up to 0.66/1.14kV
GB/T 12972.3-2008 — Flexible rubber-sheathed cables for mining purposes - Part 3: Trailing coalcutter cables with monitoring core and semiconducting screens for rated voltage of 0.66/1.14kV
GB/T 12972.6-2008 — Flexible rubber-sheathed cables for mining purposes - Part 6: Flexible cables with monitoring core and metallic screens for rated voltages up to 6/10kV
Secure payment via Stripe
Payments accepted
GB/T 12972.4-2008
$165.00