Valid

GB/T 12687.3-2010Chemical analysis methods of rare earth nitrate for growth regulator for plant -- Part 3: Determination of the water insoluble matter content -- Gravimetry (English PDF)

硝酸稀土植物生长调节剂化学分析方法 第3部分:水不溶物量的测定 重量法

Preview PDF

This is a limited preview

Buy now to download the full PDF (4 pages)

Need quotation for your management?

Get a formal quotation for GB/T 12687.3-2010 in 30 minutes.

Issued by

Standardization Administration of China

Level / Type

National · Recommended

Issue date

January 14, 2011

Implementation date

November 1, 2011

Scope

GB/T 12687.3-2010 is the English-translated version of 硝酸稀土植物生长调节剂化学分析方法 第3部分:水不溶物量的测定 重量法.

GB/T 12687.3-2010 — GB/T 12687 provisions of this part of the rare earth nitrate plant growth regulator agents Determination of the amount of water insoluble. This section applies to the determination of rare earth nitrate plant growth regulator agent in water-insoluble matter content. Measuring range. 0.10% to 0.30%.

Found what you need?

Document preview — GB/T 12687.3-2010

National Standard of the People's Republic of China

ICS
77.120.99
Classification
H 14
Replacing
GB/T 12687.8-1990

Issued by: Standardization Administration of China

Contents

  • Foreword
  • 1 Scope
  • 2 Principle of the method
  • 3 Instrument
  • 4 Sample
  • 5 Step, Analysis
  • 5.1 Sample
  • 5.3 Determination
  • 6 Calculation and presentation of analysis results

Foreword

GB/T 12687 "analysis of rare earth nitrate plant growth regulator chemical" is divided into three parts.

--- Part 1. arsenic, mercury, lead, cadmium, chromium content - Inductively Coupled Plasma Mass Spectrometry;

--- Part 2. Determination of chlorine content;

--- Part 3. Determination of the amount of water insoluble gravimetric method.

This is Part 3.

This Part replaces GB/T 12687.8-1990 "Determination of water insoluble matter content of agricultural chemical analysis of rare earth nitrate gravimetric method." this section compared with the GB/T 12687.8-1990, have the following main changes.

--- Measurement range limit adjustment from the 1.0 to 0.3 percent;

--- Increasing the precision of the terms;

--- Increased quality assurance and control provisions;

--- Standard text made editorial changes.

This part of the National Standardization Technical Committee of rare earth (SAC/TC229) centralized.

This part by the Beijing Nonferrous Metal Research Institute, China Nonferrous Metals Industry Institute of Standards Metrology and Quality is responsible for drafting.

This section is Baotou Steel Rare Earth Hi-Tech Company, Jiangyin Jiahua Advanced Material Resources Co., Ltd. participated in the drafting.

1 Scope

GB/T 12687 provisions of this part of the rare earth nitrate plant growth regulator agents Determination of the amount of water insoluble.

This section applies to the determination of rare earth nitrate plant growth regulator agent in water-insoluble matter content. Measuring range. 0.10% to 0.30%.

2 Principle of the method

The sample is dissolved in water, insoluble matter was separated by filtration which is calculated by the amount of water insoluble mass value after drying.

3 Instrument

3.1 electric oven.200 °C ± 2 °C.

3.2 Analysis of balance. a sense of the amount of 0.1mg.

3.3 glass sand funnel (filter funnel acid). P16.

4 Sample

Weighing the sample immediately after the opening.

5 Step, Analysis

5.1 Sample

Weigh the sample (4) 20g, accurate to 0.0001g.

5.2 Determination of the number of Weigh two samples (5.1) parallel determination of the mean value.

5.3 Determination

5.3.1 The sample (5.1) into 600mL beaker, 500mL about 60 °C hot water, cover the dish table. Heated to a boil in 60 °C ~ 80 °C incubated 45min, intermediate Stir a few times to completely dissolve the soluble salts, is cooled.

5.3.2 with the constant weight of glass sand funnel (3.3) by suction. Beaker with warm water 3 to 5 times, water insoluble 7-8 times.

5.3.3 The glass sand funnel (3.3) together with water-insoluble substance is placed in the oven (3.2) at 105 °C ~ 110 °C drying 1h, desiccator the cooling to room temperature, and weighed.

5.3.4 5.3.3 Repeat until the difference between two adjacent mass does not exceed 1mg.

6 Calculation and presentation of analysis results

According to equation (1) calculate the water insoluble mass fraction (%).

w (water insoluble) = m1-m0m × 100 (1) where.

Mass m1 --- glass filter and water-insoluble material in grams (g);

m0 --- glass filter mass in grams (g);

M --- quality of the sample in grams (g).

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.

How to Download GB/T 12687.3-2010

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
4 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 12687.3-2010

$105.00