Valid

GB/T 11592-2011Interface between data terminal equipment (DTE) and data circuit-terminating equipment (DCE) for start-stop transmission services on public data networks (English PDF)

公用数据网上起/止传输业务使用的数据终端设备(DTE)和数据电路终接设备(DCE)间的接口

Preview PDF

This is a limited preview

Buy now to download the full PDF (24 pages)

Need quotation for your management?

Get a formal quotation for GB/T 11592-2011 in 30 minutes.

Issued by

Standardization Administration of China

Level / Type

National · Recommended

Issue date

July 29, 2011

Implementation date

November 1, 2011

Scope

GB/T 11592-2011 is the English-translated version of 公用数据网上起/止传输业务使用的数据终端设备(DTE)和数据电路终接设备(DCE)间的接口.

GB/T 11592-2011 — The standard provides a common interface between the DTE and DCE in from ITU-TX.1 defined using the/stop transmission between the user traffic categories Physical characteristics and call control procedures, including the selection of call format and protocol information and DCE provided, comprising a two-way operation Provisions.

Found what you need?

Document preview — GB/T 11592-2011

National Standard of the People's Republic of China

ICS
33.040.50
Classification
M 14
Replacing
GB/T 11592-1989

Issued by: Standardization Administration of China

Contents

  • Preface
  • Introduction
  • 1 Scope
  • 2 DTE/DCE physical interface elements
  • 2.1 Interaction circuit
  • 2.2 Electrical Characteristics
  • 2.3 Mechanical properties
  • 2.4 The interactive fault circuit
  • 3 Call control characters and error checking
  • 4 The elements of the circuit-switched service call control phase
  • 4.1 Call control events in the process
  • 4.2 Unsuccessful call
  • 4.3 Call conflict (state 19)
  • 4.4 Direct Call
  • 4.5 Facility registration/cancellation procedures
  • 4.6 Selection, call progress and DCE provided information about the format of
  • 5 Data transfer phase
  • 5.1 Data transfer (state 12) --- 7-point circuit switched services
  • 5.2 Data transmission --- leased circuit service
  • 5.3 Data transfer (state 12) --- centralized multi-point circuit switched services
  • 6 Stitches Stage
  • 6.1 Stitches by the DTE (state 13,14,15)
  • 6.2 By the DCE stitches (state 16,17,15)
  • 6.3 DCE ready (state 1)
  • 6.4 8 stitches collision
  • 7 Test loop
  • 7.1 DTE test loop --- Category 1 loop
  • 7.2 Local test loop the loop category --- 3
  • 7.3 Network test loop --- category 2 Loop
  • Appendix A (informative) interface signaling state
  • Annex B (informative) interface signaling sequence diagrams and time-out operations
  • Appendix C (Informative Appendix) DTE and DCE minute timeout
  • Annex D (informative) selection, call progress and DCE provided information signal format
  • Annex E (informative) calls coded signal
  • Annex F (informative) facility request indicator and parameter coding
  • Appendix G (Informative Appendix) DCE provided information

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules.

This standard replaces GB/T 11592-1989 "from public data networks of data terminal equipment/stop transmission services (DTE) and data Interface circuit-terminating equipment (DCE) between. " this standard and GB/T 11592-1989/ITU-TX.20. 1984 compared to the main changes are as follows.

--- The content of Chapter 7 of the present standard of editorial changes were made, and added 7.2 and 7.3;

Appendix F --- the content of editorial changes were made, and adds F.2, F.3, F.4, F.5, F.6;

--- Appendix G for the content of editorial changes were made, and adds G.1, G.3, G.5, G.6, G.7.

This standard uses the translation method is equivalent to using ITU-TX.20. 1988 "public data from/to data terminal transmission services provided Equipment (DTE) and data circuit-terminating Interface "Equipment (DCE) between (in English).

Correspondence between the consistency of the standards of international documents and normative references of the following documents.

--- GB/T 3455 electrical characteristics for unbalanced double interface circuit (GB/T 3455-1982, idtITU-TV.28. 1980);

--- GB/T 9952 Information technology - Data communication - 15 pin DTE/DCE interface connector and contact number assignments (GB/T 9952-2008, ISO/IEC 4903. 1989, IDT);

--- GB/T 11589 public data networks and integrated services digital network (ISDN) and international user access service class types (GB/T 11589-2011, ITU-TX.1.2000, IDT);

--- GB/T 11594 on public data networks of data terminal equipment (DTE) and data circuit terminating interchange circuit equipment (DCE) between Definition Table (GB/T 11594-2009, ITU-TX.24. 1988, IDT).

The standard proposed by the Ministry of Industry and Information Technology of the People's Republic of China.

The standard by the China Communications Standards Association.

This standard was drafted. the Ministry of Industry and Information Technology and Telecommunications Research Institute, Shanghai Bell Co., Ltd.

Introduction

CCITT (now ITU-T) taking into account.

a) ITU-TX.1 and ITU-TX.2 specifies provided by a public data network services and service facilities;

b) ITU-TX.92 specifies the hypothetical reference public synchronous data networks using the connections;

c) ITU-TX.96 defines call progress signals;

d) recommendations concerning the provisions of interface elements must be defined in accordance with the hierarchy;

e) public data networks of the interface characteristics between DTE and DCE need to be standardized.

Therefore, unanimously declared. public data networks using the service type start-stop transmission, the interface between the DTE and DCE which should be consistent Provisions of this standard.

Public data from/to data transmission services Terminal Equipment (DTE) and data circuit terminating Interface Equipment (DCE) between

1 Scope

The standard provides a common interface between the DTE and DCE in from ITU-TX.1 defined using the/stop transmission between the user traffic categories Physical characteristics and call control procedures, including the selection of call format and protocol information and DCE provided, comprising a two-way operation Provisions.

2 DTE/DCE physical interface elements

2.1 Interaction circuit

Interface circuits involved are listed in Table 1, ITU-TX.24 gives the definition of these interactions circuits.

Table 1 relates to the interface circuit

Interactive circuit interactive circuit name direction from DCE to DCE G (Note) Signal ground or common return Ga DTE common return X Gb DCE common return X T send X R receiver X

NOTE. This wire can be used to reduce environmental signal interference at the interface. In the case of shielded interconnect cables, consider additional connection is ITU-TX.24 and ISO/IEC 4903 part.

2.2 Electrical Characteristics

Electrical Characteristics Electrical characteristics of the interface DCE side can follow the ITU-TX.26 regulations.

DTE side of the interface electrical characteristics can follow ITU-TX.26, ITU-TX.27 (at no load cable termination), or in accordance with Electrical characteristics defined in ITU-TV.28.

ITU-TV.28 --- DTE and ITU-TX.26 --- see DCE interconnection between ITU-TX.26 and ISO/IEC 4903.

2.3 Mechanical properties

Setting the mechanical characteristics relating to see ISO/IEC 4903.

2.4 Interaction circuit fault conditions

Contact according to the type of fault detection, fault detection circuitry of the receiver and the specific interaction between circuits, see ITU-TX.26 first 11 and ITU-TX.27 Chapter 9.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 24 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 11592-2011

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
24 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 11592-2011

$395.00