GB 9706.229-2021Medical electrical equipment - Part 2-29: Particular requirements for the basic safety and essential performance of radiotherapy simulators (English PDF)

Also coversGB9706.229-2021

Open the GB 9706.229-2021 preview as PDF

Preview — first pages of GB 9706.229-2021

This is a limited preview

Buy now to download the full PDF

Issued by

State Administration for Market Regulation, China National Standardization Administration

Level / Type

National · Mandatory

Issue date

August 10, 2021

Implementation date

May 1, 2023

Scope

GB 9706.229-2021 (Medical electrical equipment - Part 2-29: Particular requirements for the basic safety and essential performance of radiotherapy simulators) is available as an English-translated PDF.

GB 9706.229-2021 — replace. This part of GB 9706 applies to the basic safety and basic performance of radiation therapy simulators, hereinafter referred to as ME equipment. If a clause or sub-clause is specifically intended to apply only to ME equipment or ME systems, the title and content of the clause or sub-clause Will be explained. If this is not the case, this clause or sub-clause applies to ME equipment and ME systems. In addition to 7.2.13 and 8.4.1 of the general standard, the expected physiological effects of the ME equipment or ME system within the scope of this part are caused by There are no specific requirements for hazards in this section. Note. See General Standard 4.2.

Document preview — GB 9706.229-2021

National Standard of the People's Republic of China

Classification
C 43

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • 201.1 Scope, purpose and related standards1
  • 201.2 Normative references2
  • 201.3 Terms and Definitions2
  • 201.4 General requirements3
  • 201.5 General requirements for ME equipment testing3
  • 201.6 Classification of ME equipment and ME systems3
  • 201.7 ME equipment identification, marking and documentation3
  • 201.8 Protection of ME equipment against electric shock hazard (source)5
  • 201.9 Protection of ME equipment and ME system against mechanical hazards5
  • 201.10 Structure of ME equipment12
  • 201.11 Protection against over-temperature and other hazards12
  • 201.12 Accuracy of controllers and instruments and protection against dangerous outputs12
  • 201.13 Hazardous Situations and Failure Conditions of ME Equipment12
  • 201.14 Programmable Medical Electrical System (PEMS)12
  • 201.15 Structure of ME equipment12
  • 201.16 ME System12
  • 201.17 Electromagnetic compatibility of ME equipment and ME systems12
  • Appendix13
  • Appendix C (informative appendix) Guidance requirements for marking and labeling of ME equipment and ME systems14
  • Appendix AA (informative appendix) Special guidance and reasons15
  • Reference16

Foreword

GB 9706 "Medical Electrical Equipment" is divided into the following parts.

---Part 1.General requirements for basic safety and basic performance;

---Part 1-3.General requirements for basic safety and basic performance Parallel standard. Radiation protection of diagnostic X-ray equipment;

---Part 2-1.Specific requirements for the basic safety and basic performance of electron accelerators with an energy of 1MeV to 50MeV;

---Part 2-2.Special requirements for the basic safety and basic performance of high-frequency surgical equipment and high-frequency accessories;

---Part 2-3.Special requirements for basic safety and basic performance of shortwave treatment equipment;

---Part 2-4.Special requirements for the basic safety and basic performance of cardiac defibrillators;

---Part 2-5.Special requirements for the basic safety and basic performance of ultrasonic physical therapy equipment;

---Part 2-6.Special requirements for the basic safety and basic performance of microwave therapy equipment;

---Part 2-8.Special requirements for the basic safety and basic performance of therapeutic X-ray equipment with an energy of 10kV to 1MV;

---Part 2-11.Special requirements for the basic safety and basic performance of gamma beam therapy equipment;

---Part 2-12.Special requirements for the basic safety and basic performance of intensive care ventilators;

---Part 2-13.Special requirements for the basic safety and basic performance of the anesthesia workstation;

---Part 2-16.Specific requirements for the basic safety and basic performance of hemodialysis, hemodiafiltration and hemofiltration equipment;

---Part 2-17.Special requirements for the basic safety and basic performance of automatic control brachytherapy after-installation equipment;

---Part 2-18.Specific requirements for the basic safety and basic performance of endoscopic equipment;

---Part 2-19.Special requirements for basic safety and basic performance of infant incubators;

---Part 2-22.Special requirements for basic safety and basic performance of laser equipment for surgery, plastic surgery, treatment and diagnosis;

---Part 2-24.Specific requirements for the basic safety and basic performance of infusion pumps and infusion controllers;

---Part 2-25.Special requirements for basic safety and basic performance of electrocardiograph;

---Part 2-26.Special requirements for the basic safety and basic performance of EEG machines;

---Part 2-27.Special requirements for basic safety and basic performance of ECG monitoring equipment;

---Part 2-28.Special requirements for the basic safety and basic performance of medical diagnostic X-ray tube components;

---Part 2-29.Specific requirements for the basic safety and basic performance of radiotherapy simulators;

---Part 2-36.Special requirements for the basic safety and basic performance of in vitro lithotripsy equipment;

---Part 2-37.Special requirements for the basic safety and basic performance of ultrasonic diagnostic and monitoring equipment;

---Part 2-39.Special requirements for the basic safety and basic performance of peritoneal dialysis equipment;

---Part 2-43.Special requirements for the basic safety and basic performance of interventional X-ray equipment;

---Part 2-44.Special requirements for the basic safety and basic performance of X-ray computed tomography equipment;

--- Part 2-45.The basic safety and basic performance of mammography equipment and mammography stereotaxic devices

Require;

---Part 2-54.Special requirements for the basic safety and basic performance of X-ray photography and fluoroscopy equipment;

---Part 2-60.Special requirements for basic safety and basic performance of dental equipment;

---Part 2-63.Special requirements for the basic safety and basic performance of extraoral imaging dental X-ray machines;

---Part 2-65.Special requirements for the basic safety and basic performance of intraoral imaging dental X-ray machines;

---Part 2-66.Special requirements for basic safety and basic performance of hearing equipment and hearing equipment system.

This part is part 2-29 of GB 9706.

This section was drafted in accordance with the rules given in GB/T 1.1-2009.

This part replaces GB 9706.16-2015 ``Medical Electrical Equipment Part 2.Special Requirements for the Safety of Radiotherapy Simulators'', and

Compared with GB 9706.16-2015, the main technical changes are as follows.

---Chapter number and order are revised in accordance with the content of IEC 60601-2-29.2008 (see.201.1~201.17);

---Modified some terms and definitions (see.201.3).

This part uses the redrafting law to amend and adopt IEC 60601-2-29.2008 "Medical Electrical Equipment Part 2-29.Radiation Therapy Mode"

Specific requirements for the basic safety and basic performance of the proposed aircraft.

The technical differences between this part and IEC 60601-2-29.2008 and the reasons are as follows.

---Regarding normative reference documents, this section has made adjustments with technical differences to adapt to my country's technical conditions and adjustments.

The situation is collectively reflected in the chapter "Normative Reference Documents", and the specific adjustments are as follows.

* Replace IEC 61217 with GB/T 18987-2015, which is equivalent to adopting international standards.

This section has made the following editorial changes.

--- Deleted some informative "Notes";

---The term index at the end of the international standard text has been deleted.

Introduction

The requirements determined in this section serve as the manufacturer's basis for the design and manufacture of radiation therapy simulators. This section does not attempt to determine

For its optimal performance requirements, its purpose is to determine those currently considered essential for the safe operation of such ME equipment

Design features. This article sets a limit for the degradation of ME equipment performance. When the limit is reached, the ME equipment is considered to be in a fault state. example

For example, when a component fails, the interlocking action needs to be triggered correspondingly to prevent the continued operation of the ME equipment.

Medical Electrical Equipment Part 2-29.

Basic safety and basic performance of radiation therapy simulator

Dedicated requirements

201.1 Scope, purpose and related standards

In addition to the following, Chapter 1 of the general standard applies.

201.1.1 Scope

replace.

This part of GB 9706 applies to the basic safety and basic performance of radiation therapy simulators, hereinafter referred to as ME equipment.

If a clause or sub-clause is specifically intended to apply only to ME equipment or ME systems, the title and content of the clause or sub-clause

Will be explained. If this is not the case, this clause or sub-clause applies to ME equipment and ME systems.

In addition to 7.2.13 and 8.4.1 of the general standard, the expected physiological effects of the ME equipment or ME system within the scope of this part are caused by

There are no specific requirements for hazards in this section.

Note. See General Standard 4.2.

201.1.2 Purpose

replace.

The purpose of this section is to establish specific requirements for basic safety and basic performance of radiotherapy simulators (as defined in.201.3.204).

201.1.3 Parallel standards

Supplement.

This section refers to Chapter 2 of the General Standard and applicable parallel standards listed in.201.2.

The following collateral standards are not applicable.

---IEC 60601-1-10.

201.1.4 Specific standards

replace.

In the GB 9706 series, the special standards can be modified, replaced or deleted according to the special ME equipment under consideration, the general standards and parallel standards

The requirements contained in the standards. And can add other basic safety and basic performance requirements.

The requirements of specific standards take precedence over the requirements of general standards.

In this section, GB 9706.1-2020 is referred to as the general standard. Parallel standards are represented by their respective standard numbers.

The numbering of chapters and articles in this part is prefixed with "201" to correspond to the general standard (for example,.201.1 in this part corresponds to the first chapter of the general standard).

Chapter), or add the prefix "20x" to correspond to the applicable parallel standard, where "x" is the last digit of the international standard number corresponding to the parallel standard (example

For example, 202.4 in this part corresponds to the content of Chapter 4 in the collateral standard YY9706.102, and 203.4 in this part corresponds to the collateral standard

The contents of Chapter 4 in GB 9706.103, etc.).

Standardize changes to the text of the general standard by using the following words.

"Replacement" means that the chapter or article of the general standard or the applicable parallel standard is completely replaced by the content of this part.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

How to Buy GB 9706.229-2021

  1. 1Add to cart. Click the "Buy GB 9706.229-2021" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 9706.229-2021

$305.00

$260.00for partners