GB 9706.208-2021Medical electrical equipment - Part 2-8: Particular requirements for the basic safety and essential performance of therapeutic X-ray equipment operating in the range 10 kV to 1 MV (English PDF)

Also coversGB9706.208-2021

Open the GB 9706.208-2021 preview as PDF

Preview — first pages of GB 9706.208-2021

This is a limited preview

Buy now to download the full PDF

Issued by

State Administration for Market Regulation, China National Standardization Administration

Level / Type

National · Mandatory

Issue date

August 10, 2021

Implementation date

May 1, 2023

Scope

GB 9706.208-2021 (Medical electrical equipment - Part 2-8: Particular requirements for the basic safety and essential performance of therapeutic X-ray equipment operating in the range 10 kV to 1 MV) is available as an English-translated PDF.

GB 9706.208-2021 — replace. This part of GB 9706 is applicable to therapeutic X-ray equipment with AC power supply and nominal X-ray tube voltage of 10kV~1MV The basic safety and basic performance. Hereinafter referred to as ME equipment. Note. This section covers distance radiotherapy and brachytherapy. If a chapter or sub-clause is clearly stipulated as only applicable to ME equipment, or only applicable to ME systems, the chapter or sub-clause The title and content of the chapter will be explained. If this is not the case, then the clause or sub-clause applies to both ME equipment and ME system.

Document preview — GB 9706.208-2021

National Standard of the People's Republic of China

Classification
C 43

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • 201.1 Scope, purpose and related standards1
  • 201.2 Normative references2
  • 201.3 Terms and Definitions2
  • 201.4 General requirements3
  • 201.5 General requirements for ME equipment testing3
  • 201.5.5 Power supply voltage, current type, power supply nature, frequency5
  • 201.6 Classification of ME equipment and ME systems5
  • 201.7 ME equipment identification, marking and documentation6
  • 201.8 Protection against electrical injuries from medical electrical equipment8
  • 201.9 Protection against mechanical damage from ME equipment and ME systems9
  • 201.10 Protection against unwanted or excessive radiation risks9
  • 201.11 Protection against over-temperature and other hazards21
  • 201.12 Accuracy of working data and prevention of dangerous output21
  • 201.13 Hazardous and fault conditions of medical electrical equipment21
  • 201.14 Programmable Electrical Medical System21
  • 201.15 Interpretation of medical electrical equipment21
  • 201.16 Medical electrical system21
  • 201.17 Electromagnetic compatibility of medical electrical equipment and medical electrical systems21
  • Appendix22
  • Reference23
  • Table.201.101 Data required in the technical description provides support.201.10 Field and type test compliance4
  • Table.201.102 Allowable leakage radiation9
  • Table.201.103 Allowable radiation value of X-ray tube assembly with beam limiting device11
  • Table.201.104 Measurement Table20

Foreword

GB 9706 "Medical Electrical Equipment" is divided into the following parts.

---Part 1.General requirements for basic safety and basic performance;

---Part 1-3.General requirements for basic safety and basic performance Parallel standard. Radiation protection of diagnostic X-ray equipment;

---Part 2-1.Special requirements for the basic safety and basic performance of electron accelerators with energy from 1MeV to 50MeV;

---Part 2-2.Special requirements for the basic safety and basic performance of high-frequency surgical equipment and high-frequency accessories;

---Part 2-3.Special requirements for basic safety and basic performance of shortwave treatment equipment;

---Part 2-4.Special requirements for the basic safety and basic performance of cardiac defibrillators;

---Part 2-5.Special requirements for the basic safety and basic performance of ultrasonic physical therapy equipment;

---Part 2-6.Special requirements for the basic safety and basic performance of microwave therapy equipment;

---Part 2-8.Special requirements for the basic safety and basic performance of therapeutic X-ray equipment with an energy of 10kV to 1MV;

---Part 2-11.Special requirements for the basic safety and basic performance of gamma beam therapy equipment;

---Part 2-12.Special requirements for the basic safety and basic performance of intensive care ventilators;

---Part 2-13.Special requirements for the basic safety and basic performance of the anesthesia workstation;

---Part 2-16.Specific requirements for the basic safety and basic performance of hemodialysis, hemodiafiltration and hemofiltration equipment;

---Part 2-17.Special requirements for the basic safety and basic performance of automatic control brachytherapy after-installation equipment;

---Part 2-18.Specific requirements for the basic safety and basic performance of endoscopic equipment;

---Part 2-19.Special requirements for basic safety and basic performance of infant incubators;

---Part 2-22.Special requirements for basic safety and basic performance of laser equipment for surgery, plastic surgery, treatment and diagnosis;

---Part 2-24.Specific requirements for the basic safety and basic performance of infusion pumps and infusion controllers;

---Part 2-25.Special requirements for basic safety and basic performance of electrocardiograph;

---Part 2-26.Special requirements for the basic safety and basic performance of EEG machines;

---Part 2-27.Special requirements for basic safety and basic performance of ECG monitoring equipment;

---Part 2-28.Special requirements for the basic safety and basic performance of medical diagnostic X-ray tube components;

---Part 2-29.Specific requirements for the basic safety and basic performance of radiotherapy simulators;

---Part 2-36.Special requirements for the basic safety and basic performance of in vitro lithotripsy equipment;

---Part 2-37.Special requirements for the basic safety and basic performance of ultrasonic diagnostic and monitoring equipment;

---Part 2-39.Special requirements for the basic safety and basic performance of peritoneal dialysis equipment;

---Part 2-43.Special requirements for the basic safety and basic performance of interventional X-ray equipment;

---Part 2-44.Special requirements for the basic safety and basic performance of X-ray computed tomography equipment;

--- Part 2-45.The basic safety and basic performance of mammography equipment and mammography stereotaxic devices

Require;

---Part 2-54.Special requirements for the basic safety and basic performance of X-ray photography and fluoroscopy equipment;

---Part 2-60.Special requirements for basic safety and basic performance of dental equipment;

---Part 2-63.Special requirements for the basic safety and basic performance of extraoral imaging dental X-ray machines;

---Part 2-65.Special requirements for the basic safety and basic performance of intraoral imaging dental X-ray machines;

---Part 2-66.Special requirements for basic safety and basic performance of hearing equipment and hearing equipment system.

This part is part 2-8 of GB 9706.

This section was drafted in accordance with the rules given in GB/T 1.1-2009.

This part replaces GB 9706.10-1997 "Medical Electrical Equipment Part 2.Special Requirements for the Safety of Therapeutic X-ray Generating Devices",

Compared with GB 9706.10-1997, the main technical changes are as follows.

---Added field test information that should be included in the technical description (see.201.5.4);

---Added the requirements for the external marking of X-ray tubes (see.201.7.2.2);

---Added the requirements for the treatment console outside the treatment room [see.201.10.1.2.105.1];

---Added the signal requirements for the console [see.201.10.1.2.105.6];

---Added the requirements for the transition time interval [see.201.10.1.2.105.7];

---Added the requirements for X-ray tube replacement [see.201.10.1.2.105.8];

--- Increased the limit of absorbed dose (see.201.10.1.2.109.1), the choice of irradiation time or MU (see.201.10.1.2.109.2),

Display of preset irradiation time or MU (see.201.10.1.2.109.3), system design (see.201.10.1.2.109.4), irradiation time

Or MU display (see.201.10.1.2.109.5), irradiation control (see.201.10.1.2.109.6), moving beam radiotherapy

Irradiation control (see.201.10.1.2.109.7).

This part uses the redrafting law to amend and adopt IEC 60601-2-8.2015 "Medical Electrical Equipment Part 2-8.Energy is 10kV

Specific requirements for the basic safety and basic performance of 1MV therapeutic X-ray equipment".

The technical differences between this part and IEC 60601-2-8.2015 and the reasons are as follows.

---Regarding normative reference documents, this section has made adjustments with technical differences to adapt to my country's technical conditions and adjustments.

The situation is collectively reflected in the chapter "Normative Reference Documents", and the specific adjustments are as follows.

* Replace IEC 60601-2-1.2009 with GB 9706.201-2020, which is modified to adopt international standards.

* Replace IEC 61217 with GB/T 18987-2015, which is equivalent to adopting international standards.

This section has made the following editorial changes.

--- Deleted some informative "Notes";

---The term index at the end of the international standard text has been deleted.

201.1 Scope, purpose and related standards

In addition to the following, Chapter 1 of the general standard applies.

201.1.1 Scope

replace.

This part of GB 9706 is applicable to therapeutic X-ray equipment with AC power supply and nominal X-ray tube voltage of 10kV~1MV

The basic safety and basic performance. Hereinafter referred to as ME equipment.

Note. This section covers distance radiotherapy and brachytherapy.

If a chapter or sub-clause is clearly stipulated as only applicable to ME equipment, or only applicable to ME systems, the chapter or sub-clause

The title and content of the chapter will be explained. If this is not the case, then the clause or sub-clause applies to both ME equipment and ME

system.

201.1.2 Purpose

replace.

The purpose of this section is to develop specific basic safety and basic performance of therapeutic X-ray equipment. It includes accuracy on performance

And repeatability requirements, these requirements are related to the radiation quality and quantity of ionizing radiation generated, so this is also a safety consideration

problem.

201.1.3 Parallel standards

Supplement.

This section refers to the parallel standards listed in Chapter 2 of the General Standards and.201.2 of this section.

GB 9706.12 and IEC 60601-1-10 are not applicable. All other published parallel standards in the GB 9706 series follow the release

And apply.

201.1.4 Specific standards

replace.

In the GB 9706 series, the special standards can be modified, replaced or deleted according to the special ME equipment under consideration, the general standards and parallel standards

The requirements contained in the standards. And can add other basic safety and basic performance requirements.

The requirements of specific standards take precedence over the requirements of general standards.

In this section, GB 9706.1-2020 is referred to as the general standard. Parallel standards are represented by their respective standard numbers.

The numbering of chapters and articles in this part is prefixed with "201" to correspond to the general standard (for example,.201.1 in this part corresponds to the first chapter of the general standard).

Chapter), or add the prefix "20x" to correspond to the applicable parallel standard, where "x" is the last digit of the international standard number corresponding to the parallel standard (example

For example, 202.4 in this part corresponds to the content of Chapter 4 in the collateral standard YY9706.102, and 203.4 in this part corresponds to the collateral standard

The contents of Chapter 4 in GB 9706.103, etc.).

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

How to Buy GB 9706.208-2021

  1. 1Add to cart. Click the "Buy GB 9706.208-2021" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 9706.208-2021

$365.00

$310.00for partners