GB 5009.2-2024 (National food safety standard - Determination of relative density of food) is available as an English-translated PDF.

GB 5009.2-2024 — This standard specifies the method for the determination of the relative density of liquid foods. This standard is applicable to the determination of the relative density of liquid foods. Method A - Density bottle method

Document preview — GB 5009.2-2024

National Standard of the People's Republic of China

Issued by: National Health Commission and State Administration for Market Regulation

Contents

  • Foreword...3
  • 1 Scope...4
  • Method A - Density bottle method...4
  • 2 Principle...4
  • 3 Instruments and equipment...4
  • 4 Analysis steps...4
  • 5 Expression of analysis results...5
  • 6 Precision...5
  • Method B - Balance method...5
  • 7 Principle...5
  • 8 Instruments and equipment...6
  • 9 Analysis steps...6
  • 10 Expression of analysis results...6
  • 11 Precision...7
  • Method C - Hydrometer method...7
  • 12 Principle...7
  • 13 Instruments and equipment...7
  • 14 Analysis steps...7
  • 15 Expression of analysis results...7
  • 16 Precision...8
  • Method D - Oscillating u-tube digital densimeter method...8
  • 17 Principle...8
  • 18 Instruments and equipment...8
  • 19 Analysis steps...9
  • 20 Presentation of analysis results...9
  • 21 Precision...9
  • Appendix A Density bottle diagram...10
  • Appendix B Schematic diagram of Westphal relative density balance...11

Foreword

This standard replaces GB 5009.2-2016 National food safety standard - Determination

of relative density of food.

Compared with GB 5009.2-2016, the main changes in this standard are as follows.

-- A calculation formula is added in Method C;

-- Method D, oscillating U-tube digital densimeter method, is added.

National food safety standard - Determination of relative

density of food

1 Scope

This standard specifies the method for the determination of the relative density of liquid

foods.

This standard is applicable to the determination of the relative density of liquid foods.

Method A - Density bottle method

2 Principle

The masses of water and the sample filled in the same density bottle at 20 °C are

measured, respectively. The volume of the density bottle, which is the sample volume,

can be determined from the mass of the water. The density of the sample can be

calculated based on the mass and volume of the sample. The ratio of sample density to

water density is the relative density of the sample.

3 Instruments and equipment

3.1 Density bottle. Precision density bottle, see Figure A.1 in Appendix A.

3.2 Constant temperature water bath. The accuracy is +/-1 °C.

4 Analysis steps

Take a clean, dry, constant weight, and accurately weighed density bottle. After filling

it with the sample, place it in a water bath and soak it for 0.5 hours until the temperature

of the sample inside reaches (20+/-1) °C;

5 Expression of analysis results

The relative density of the sample is calculated according to formula (1).

6 Precision

The absolute difference between two independent determination results obtained under

repeatability conditions shall not exceed 5% of the arithmetic mean.

7 Principle

At 20°C, the buoyancy of the glass hammer in water and in the sample are measured,

respectively.

8 Instruments and equipment

8.1 Westphal relative density balance. The sensitivity is 0.1 mg; see Figure B.1 in

Appendix B.

9 Analysis steps

When measuring, place the stand on a flat table, place the beam on the knife edge, hang

a weight on the hook, adjust the lifting knob to the appropriate height, and rotate the

zero-setting knob to make the two pointers match. Then remove the weight, hang up

the glass hammer, add water to the 4/5 position in the glass cylinder, and put it into a

constant temperature water bath; make the water temperature in the glass cylinder

balance and stabilize at (20+/-1) degrees C, let the glass hammer sink to the glass cylinder, try

placing four kinds of riders until the two pointers on the beam coincide, and the reading

at this time is P1;

10 Expression of analysis results

The relative density of the sample is calculated according to formula (2).

11 Precision

The absolute difference between two independent determination results obtained under

repeatability conditions shall not exceed 5% of the arithmetic mean.

12 Principle

Archimedes' principle is used; the liquid sample to be tested is poured into a higher

container, and then the hydrometer is placed into the liquid sample after the temperature

stabilizes at 20 °C.

13 Instruments and equipment

13.1 Hydrometer. There is a scale label in the upper thin tube to indicate the density

reading.

13.2 Constant temperature water bath. The accuracy is +/-1 °C.

14 Analysis steps

Wash and dry the hydrometer, and slowly place it into a suitable measuring cylinder

containing an appropriate amount of liquid sample to be tested, and the cylinder has

been at (20+/-1) °C in a constant temperature water bath. Do not let the hydrometer touch

the wall and bottom of the container.

15 Expression of analysis results

The relative density of the sample is calculated according to formula (3).

16 Precision

The absolute difference between two independent measurement results obtained under

repeatability conditions shall not exceed 5% of the arithmetic mean.

17 Principle

Electromagnetic induces the oscillation of the glass U-tube, the magnitude of the

oscillation frequency squared is linearly related to the density of the sample in the

measuring cell, and the density of the sample is thus determined.

18 Instruments and equipment

18.1 Oscillating U-tube digital densimeter. with automatic viscosity correction and

temperature and thermal balance functions.

19 Analysis steps

19.1 Calibration of the instrument

Before testing, calibrate the instrument according to the instructions of the instrument.

20 Presentation of analysis results

The result is expressed to the third decimal place.

21 Precision

The absolute difference between two independent measurement results obtained under

repeatability conditions shall not exceed 5% of the arithmetic mean.

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

Referenced standards

How to Buy GB 5009.2-2024

  1. 1Add to cart. Click the "Buy GB 5009.2-2024" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 5009.2-2024

$125.00

$105.00for partners