GB 30531-2014Minimum allowable values of energy efficiency and energy efficiency grades for commercial gas cooking appliances (English PDF)
Also coversGB30531-2014
Open the GB 30531-2014 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
AQSIQ; SAC
Level / Type
National · Mandatory
Issue date
April 28, 2014
Implementation date
January 1, 2015
Scope
GB 30531-2014 (Minimum allowable values of energy efficiency and energy efficiency grades for commercial gas cooking appliances) is available as an English-translated PDF.
GB 30531-2014 — This Standard specifies energy efficiency grades, minimum allowable values of energy efficiency, energy saving evaluation values, test methods and inspection rules for commercial gas cooking appliance. This Standard is applicable to Chinese gas cooking stove that uses gas as energy, of which rated heat load of a single burner is not more than 60kW (hereinafter referred to as cooking stove), gas cooking oven of which rated heat load per burner is not more than 80kW and nominal diameter of oven is not less than 600mm (hereinafter referred to as cooking oven) as well as gas steamer of which rated thermal load is not more than 80kW and steam chamber steam pressure is not more than 500Pa (gauge pressure) (hereinafter referred to as steamer). Gas referred in this Standard is gas specified in GB/T 13611.
Document preview — GB 30531-2014
National Standard of the People's Republic of China
Issued by: AQSIQ; SAC
Contents
- Foreword3
- 1 Scope4
- 2 Normative references4
- 3 Terms and definitions4
- 4 Technical requirements5
- 5 Test and calculation methods6
- 6 Inspection rules6
1 Scope
This Standard specifies energy efficiency grades, minimum allowable values of energy efficiency, energy saving evaluation values, test methods and inspection rules for commercial gas cooking appliance.
This Standard is applicable to Chinese gas cooking stove that uses gas as energy, of which rated heat load of a single burner is not more than 60kW (hereinafter referred to as cooking stove), gas cooking oven of which rated heat load per burner is not more than 80kW and nominal diameter of oven is not less than 600mm (hereinafter referred to as cooking oven) as well as gas steamer of which rated thermal load is not more than 80kW and steam chamber steam pressure is not more than 500Pa (gauge pressure) (hereinafter referred to as steamer).
Gas referred in this Standard is gas specified in GB/T 13611.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 13611, Classification and basic characteristics of city gas CJ/T 28, Chinese cooking gas appliances CJ/T 187, Gas steaming oven CJ/T 392, Commercial gas oven for cooking
3 Terms and definitions
For the purposes of this document, the terms and definitions defined in CJ/T 28, CJ/T 187 and CJ/T 392 as well as the followings apply.
Evaluating values of energy conservation for commercial gas cooking appliances are grade-2 values of energy efficiency in Table 1.
5 Test and calculation methods
5.1 Test conditions and test methods for cooking stove are in accordance with CJ/T 28.
5.2 Test conditions and test methods for cooking oven are in accordance with CJ/T 392.
5.3 Test conditions and test methods for steamer are in accordance with CJ/T 187.
5.4 Thermal efficiency value after heat load is weighted average for multi-fog cooking stove and cooking oven is calculated according to formula (1):
Where, Ii - actual measured converted thermal load of each fog, in kilowatts (kW);
etai - thermal efficiency of each fog, in percentage (%).
6 Inspection rules
6.1 Exit-factory inspection Minimum allowable values of energy efficiency shall be exit-factory inspection item for cooking stove, cooking oven and steamer. Products of which efficiency is inspected as failed to meet requirements in 4.3 are not allowed to exit factory.
6.2 Type inspection
6.2.1 In one of following cases for cooking stove, cooking oven and steamer, type inspection shall be carried out:
a) test stereotypes identification of new product;
b) changes in product design, process or material used which may affect product performances;
c) required by quality and technical supervision department.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
How to Buy GB 30531-2014
- 1Add to cart. Click the "Buy GB 30531-2014" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 13611-2018 — Classification and basic characteristics of city gas
GB/T 13611-2026 — Classification and basic characteristics of urban gas
GB 11118-2026 — Hydraulic fluids (L-HL, L-HM, L-HV, L-HS and L-HG type)
Secure payment via Stripe
Payments accepted
GB 30531-2014
$70.00