GB 29707-2013Determination of marker residues of Amitraz in milk by Gas Chromatographic method (English PDF)
食品安全国家标准 牛奶中双甲脒残留标志物残留量的测定 气相色谱法
This is a limited preview
Buy now to download the full PDF (7 pages)
Need quotation for your management?
Get a formal quotation for GB 29707-2013 in 30 minutes.
Issued by
Ministry of Agriculture of the People's Republic of China, National Health and Family Planning Commission of the People's Republic of China
Level / Type
National · Mandatory
Issue date
September 16, 2013
Implementation date
January 1, 2014
Scope
GB 29707-2013 is the English-translated version of 食品安全国家标准 牛奶中双甲脒残留标志物残留量的测定 气相色谱法.
GB 29707-2013 — This standard specifies the sample preparation and gas chromatographic method for the detection of residues in milk amitraz marker. This standard applies to methyl aniline residues in milk amitraz markers 2,4.
Found what you need?
Document preview — GB 29707-2013
National Standard of the People's Republic of China
- ICS
- 67.020
- Classification
- C 53
Issued by: Ministry of Agriculture of the People's Republic of China, National Health and Family Planning Commission of the People's Republic of China
Contents
- 1 Scope
- 2 Normative references
- 4 Reagents and materials
- 5 Apparatus
- 6.1 Preparation of the sample
- 7.1 Preparation of standard curve
- 7.2 Extraction and hydrolysis
- 7.3 Derivatives and purify
- 7.4 Determination
- 7.5 Blank test
- 9 Test method sensitivity, accuracy and precision
- 9.1 Sensitivity
- 9.2 Accuracy
- 9.3 Precision
1 Scope
This standard specifies the sample preparation and gas chromatographic method for the detection of residues in milk amitraz marker.
This standard applies to methyl aniline residues in milk amitraz markers 2,4.
2 Normative references
The following documents for the application of this document is essential. For dated references, only applies to the version dated paper Pieces. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 6682 Water for analytical laboratory specifications and test methods Principle 3 the specimens remaining amitraz, extracted with aqueous sodium hydroxide, hydrolysis, extraction, derivatization heptafluorobutyric anhydride, gas chromatography - electron capture detection Detection measurement method, external standard.
4 Reagents and materials
The following reagents used, unless otherwise stated were of analytical reagent; water as a water line with GB/T 6682 provisions.
4.1 pairs formamidine reference. content >=99%; 2,4- dimethylaniline reference. content of >=95%.
4.2 Sodium hydroxide. pure class.
Sodium bicarbonate 4.3. excellent pure.
Anhydrous sodium sulfate 4.4. excellent pure.
4.5 heptafluorobutyric anhydride. chromatography.
4.6 hexane. chromatography.
4.7 1mol/L sodium hydroxide solution. take sodium hydroxide 40g, dissolved and diluted with water to 1000mL.
4.8 alkaline aqueous solution. water 1000mL, with 1mol/L sodium hydroxide solution was adjusted to pH 9.0.
4.9 with saturated sodium bicarbonate solution. Take bicarbonate 10.35g, dissolved and diluted with water to 1000mL.
4.10 1mg/mL, amitraz and 2,4-dimethylaniline standard stock solution. Weigh accurately amitraz and 2,4-dimethylaniline reference substance 10mg, respectively 10mL volumetric flask, dissolve and dilute with n-hexane to the mark, formulated as amitraz standard stock concentration of 1mg/mL of and 2,4-dimethyl aniline solution standard stock solution. 2 °C ~ 8 °C storage period of three months.
4.11 10µg/mL working standard solutions. precise amount of 1mg/mL standard stock solution of amitraz and 2,4-dimethylaniline standard stock 1.0 mL each of the appropriate amount of liquid, in 100mL volumetric flask, diluted to volume with hexane, formulated at a concentration of 10µg/mL of the working standard liquid. 2 °C ~ 8 °C from light, one week period.
5 Apparatus
5.1 Gas chromatograph. with an electron capture detector.
5.2 Analytical balance. a sense of volume 0.00001g.
5.3 Balance. a sense of the amount of 0.01g.
5.4 centrifuge.
5.5 vortex mixer.
5.6 homogenizer.
5.7 Ovens.
5.8 polypropylene centrifuge tube.
5.9 stoppered centrifuge tube.
5.10 round-bottomed flask.
Preparation and Storage of sample 6
6.1 Preparation of the sample
An appropriate amount of fresh or frozen or blank test milk and mix well.
--- the test sample taken after homogenization, as the feed try.
--- blank sample taken after homogenization, as a blank sample.
--- blank sample taken after homogenization, adding a suitable concentration of the standard working solution, is added as a blank sample.
Save 6.2 sample
Or less at -20 °C.
Determination Step 7
7.1 Preparation of standard curve
The precise amount of 2,4-dimethylaniline appropriate amount of standard stock solution, diluted with hexane, and formulated to a concentration of 10,20,50,100,200 400ng/mL of the standard solution series, from each 2.0 mL, the processing according to the derivatization step, gas phase chromatography. To the measured peak area for the vertical take Standard, the standard concentration corresponding to abscissa, the standard curve. Seeking regression equation and correlation coefficient.
7.2 Extraction and hydrolysis
Sample Weigh 5g ± 0.05g, polypropylene centrifuge tube, the aqueous alkaline solution was added 10mL, Vortex, 4200r/min centrifugal 10min, the supernatant was further polypropylene centrifuge tube, the aqueous alkaline solution added to the residue 10mL, extraction was repeated once, the two supernatants were combined liquid. Oven temperature was allowed to stand at 70 deg.] C in 50min, cooled, hexane was added 10mL, Vortex, standing 5min, 4200r/min centrifugal 10min, the upper n-hexane solution in a round bottom flask, was added 5 mL of n-hexane extraction was repeated once underlayer, the two hexane layer were combined, in 45 °C transferred evaporated to dryness, the residue was dissolved with n-hexane 2.0mL standby.
7.3 Derivatives and purify
Stock solution taken in a stoppered centrifuge tube, add 10 L heptafluorobutyric anhydride, mixed, at 60 deg.] C thermostat 90min, 30min intervals therebetween removed Ultrasound 5min. After standing derived 10min, saturated sodium bicarbonate solution was added 2mL, mixing, the organic layer was taken, dried over anhydrous sodium sulfate was added to 2g Water, gas phase chromatography.
7.4 Determination
7.4.1 Chromatographic conditions
7.4.1.1 Column. Rtx-1 capillary column (30m × 0.25mm), or equivalent person.
7.4.1.2 Column temperature. programming, see Table 1.
Table 1 Temperature Programmed Table
Heating rate
°C/min
The initial temperature Residence time min 7.4.1.3 column flow rate. 1mL/min, analysis time. 27min.
7.4.1.4 Inlet temperature. 250 °C.
7.4.1.5 Injection volume. 1µL.
7.4.1.6 Carrier gas. nitrogen gas (purity >=99.999%), 30mL/min.
7.4.1.7 split mode. split split ratio 50 to 1.
7.4.1.8 Detector temperature. 300 °C.
7.4.2 Assay
Take a sample solution and standard solutions corresponding, for single or multi-point calibration, by external standard method, the peak area is calculated. Standard solution and sample solution Amitraz solution of 2,4-dimethylaniline and the response value should be within the linear range of the detection instrument. In the chromatographic conditions, the standard solutions and Blank HPLC sample solution was added in Appendix A. FIG.
7.5 Blank test
But without addition of the sample, the same steps employed in parallel operation.
Calculation and Expression of Results 8 Residues in the specimens amitraz (µg/kg) according to formula (1).
A × cS × V × 1.21
AS × m
Where.
--- for the X-feed try amitraz residues micrograms per kilogram (µg/kg);
A --- peak area of sample solution heptafluoro 2,4-dimethylphenoxy butanamide;
Standard working solution concentration cS --- 2,4-dimethylaniline, expressed in nanograms per milliliter (ng/mL);
V --- volume was extracted with hexane, milliliters (mL);
2,4-dimethyl aniline 1.21 --- double correction coefficient calculation formamidine;
--- the AS peak area of the standard working solution of 2,4-dimethylbenzene heptafluoro butanamide;
m --- try supply feed mass in grams (g).
Note. The blank value should be subtracted from the results, expressed as the arithmetic mean of the measurement result measured parallel to three significant figures.
9 Test method sensitivity, accuracy and precision
9.1 Sensitivity
The detection limit of the method was 2µg/kg, the limit of quantitation of 5µg/kg.
9.2 Accuracy
This method of adding 5µg/kg ~ 20µg/kg on recovery levels of 70% to 110%.
9.3 Precision
The relative standard deviation of the method <=15%, inter-assay relative standard deviation <=20%.
Appendix A
Chromatogram
FIG A.1 2,4- ditolylamine chromatogram of the standard solution (10µg/L)
Figure A.2 milk blank sample chromatogram
Figure A.3 milk sample blank add amitraz chromatogram (5µg/kg)
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.
Referenced standards
How to Download GB 29707-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6682-2008 — Water for analytical laboratory use - Specification and test methods
GB 11118-2026 — Hydraulic fluids (L-HL, L-HM, L-HV, L-HS and L-HG type)
GB 11557-2026 — Provisions for protecting drivers from injury by the steering mechanism of motor vehicles
Secure payment via Stripe
Payments accepted
GB 29707-2013
$115.00