GB 22622-2008Propamocarb hydrochloride aqueous solution (English PDF)
霜霉威盐酸盐水剂
This is a limited preview
Buy now to download the full PDF (6 pages)
Need quotation for your management?
Get a formal quotation for GB 22622-2008 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Mandatory
Issue date
December 17, 2008
Implementation date
June 1, 2009
Scope
GB 22622-2008 is the English-translated version of 霜霉威盐酸盐水剂.
GB 22622-2008 — This Chinese standard specifies the propamocarb hydrochloride salt agent requirements, test methods and marking, labeling, packaging and storage.
Found what you need?
Document preview — GB 22622-2008
National Standard of the People's Republic of China
- ICS
- 65.100.30
- Classification
- G 25
Issued by: Standardization Administration of China
Contents
- Foreword
- 2 Normative references
- 3 Requirements
- 4.1 Sampling
- 4.2 Identification Test
- 4.3 Determination of propamocarb hydrochloride salt mass fraction
- 4.4 Determination of water insoluble mass fraction
- 4.6 Dilution stability test
- 4.7 Low temperature stability test
- 4.8 Thermal storage stability test
- 4.9 Product testing and acceptance
- 5 Marking, labeling, packaging, storage and transportation
Foreword
The standard Chapter 3, Chapter 5 are mandatory, the rest are recommended.
Appendix A of this standard is an informative annex.
The standard proposed by China Petroleum and Chemical Industry Association.
This standard by the National Standardization Technical Committee on Pesticides (SAC/TC133) centralized.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
Determination of GB/T 1601 Pesticides pH value GB/T 1604 Goods pesticide regulations for acceptance GB/T 1605-2001 Sampling Method commercial pesticides GB 3796 pesticide packaging General GB/T 4472 chemical product density, relative density measurement General GB/T 19137-2003 Pesticide cryogenic stability Determination 19136-2003 Thermal storage stability of pesticides GB/T Determination
3 Requirements
3.1 Composition and appearance. This product should be compliant propamocarb (hydrochloride) original drug or propamocarb hydrochloride parent drug is made, the appearance of a homogeneous liquid Body, no obvious suspended solids and sediments.
3.2 propamocarb hydrochloride salt water should meet the requirements of Table 1.
Table 1 propamocarb hydrochloride salt water control project indicators
project
index
722g/L 35.0%
Propamocarb hydrochloride salt mass fraction a /% 66.5 ± 2.5 35.0 ± 1.8 Propamocarb hydrochloride concentration (20 °C) / (g/L) 722 ± 25 -Water-insoluble mass fraction /% <= 0.3 pH range of 3.0 to 7.0 Dilution stability (diluted 20 times) Qualified Low temperature stability b a qualified Thermal storage stability b a qualified when a dispute arises when quality to propamocarb mass fraction of arbitration.
b low temperature stability, thermal storage stability test under normal production conditions, every 3 months test at least once.
Test Method 4
4.1 Sampling
Carried out according to GB/T 1605-2001 "liquid formulation sampling" method. Determined by sampling a random number table method packages, the final sample size not less than 250mL.
4.2 Identification Test
HPLC --- The identification test can be carried out simultaneously with the determination of propamocarb hydrochloride salt mass fraction. In the same chromatographic operation Under the conditions, the sample solution to a chromatographic retention time and the standard solution of the main peak retention time, the relative difference should 1.5% or less.
4.3 Determination of propamocarb hydrochloride salt mass fraction
4.3.1 Method summary
Sample was dissolved in distilled water to acetonitrile + 1.5% ammonia water as the mobile phase, to use the hybrid silica as filler and alkali resistance condition C18 is not Stainless steel column and UV detector, other than the standard method of sample propamocarb reverse phase HPLC separation and determination. It can also be used to Si100 is filling a stainless steel column and UV detector to detect chromatographic operating conditions, see Appendix A.
4.3.2 Reagents and solutions
Acetonitrile. HPLC grade;
Water. The new secondary steam distilled water;
Propamocarb (or propamocarb hydrochloride) standard. a known mass fraction >=99.0%.
4.3.3 Instruments
High performance liquid chromatography. a variable wavelength UV detector and quantitative injection valve;
Chromatographic data processor or chromatography workstation;
Column. 150mm × 3.9mm (i.d.) Stainless steel column, built XTerraRP18,5µm filler (or other equivalent effect color the column);
Filter. pore size of about 0.45µm;
Micro injector. 50µL;
Ultrasonic cleaner.
4.3.4 HPLC operating conditions
Mobile phase. psi (acetonitrile .1.5% aqueous ammonia) = 20.80;
The mobile phase flow rate. 1.0mL/min;
Column temperature. room temperature (temperature change should not exceed 2 °C);
Detection wavelength. 210nm;
Injection volume. 20µL;
Retention time. propamocarb about 5.8min.
HPLC operating conditions described above, the Department of typical operating parameters. According to the characteristics of different instruments, given operating parameters adjusted as appropriate, in order to obtain the best results. HPLC view of a typical propamocarb hydrochloride salt water is shown in Figure 1.
1 --- propamocarb.
Figure 1 propamocarb hydrochloride salt water by high performance liquid chromatogram
4.3.5 Measuring step
4.3.5.1 Sample solution preparation
Weigh propamocarb (propamocarb hydrochloride) Sample of about 0.05g (accurate to 0.0002g), placed in 100mL volumetric flask with distilled water solution Solution and diluted to the mark.
4.3.5.2 Sample solution preparation
Weigh containing propamocarb approximately 0.05g sample (accurate to 0.0002g), placed in 100mL volumetric flask, and diluted with distilled water to the mark. Through 0.45µm membrane filter and set aside.
4.3.5.3 1.5% ammonia preparation 1000mL of distilled water, was added 15mL accurate mass fraction of about 25% aqueous ammonia, shake. Through 0.45µm membrane filter, stand-by.
4.3.5.4 Determination
Under the above chromatographic operating conditions, after the instrument is stable, continuous injection of several doses of the standard solution until the two adjacent needles propamocarb relative peak area After the change of less than 1.5%, according to the solution, sample solution, sample solution, standard order of standard solution was measured.
4.3.6 Calculation
The two doses of the standard solution of two injections of the sample solution and measured before and after the sample solution propamocarb peak areas are averaged. Cream sample the mass fraction of propamocarb hydrochloride 1 (%) according to equation (1) (standard when propamocarb hydrochloride) or formula (2) (standard of propamocarb time) is calculated, Mass concentration rho propamocarb hydrochloride (g/L) according to equation (3) is calculated.
Where.
A1 --- the standard solution, the average propamocarb peak area;
A2 --- sample solution, the average propamocarb peak area;
224.7 --- molecular weight propamocarb hydrochloride;
188.3 --- propamocarb molecular weight;
--- Standard samples propamocarb (propamocarb hydrochloride) mass fraction, expressed as a percentage;
4.3.7 Allowable difference
The relative deviation of two parallel determination results shall not be greater than ± 2%, whichever is the arithmetic mean as a measurement result.
4.4 Determination of water insoluble mass fraction
4.4.1 Method summary
Samples dissolved in water, all insolubles were filtered off, dried and weighed.
4.4.2 Instruments
Weighing bottle;
Glass sand core crucible. G3;
Suction flask. 100mL;
Oven. 105 °C ± 2 °C.
4.4.3 Measuring step
At 105 °C in the sand core glass crucible and dried to constant weight (accurate to 0.0002g). Weigh a sample of about 20g (accurate to 0.01g), Rinsed with 200mL of water was transferred to a graduated cylinder, stoppered, shaken violently, so that soluble dissolved. This solution was sintered glass crucible Filtered, washed with distilled water residue in the crucible, each with 25mL, washed three times total. Set glass frit crucible and the residue was baked at 105 °C Oven dried to constant weight (accurate to 0.0002g).
4.4.4 Calculation
2 water insoluble mass fraction (%), according to equation (4) Calculated.
100 (4)
Where.
According to GB/T 1601 carried out.
4.6 Dilution stability test
4.6.1 Reagents and Instruments
Standard hard water. rho (Ca 2 ++ Mg2 +) = 342mg/L;
Cylinder. 100mL;
Water bath. 30 °C ± 2 °C;
Pipette. 5mL.
4.6.2 Test procedure
With pipette 5mL sample, placed in 100mL measuring cylinder and diluted to the mark with standard hard water, and mix. Add this cylinder 30 °C ± 2 °C of water bath, allowed to stand for 1h. As dilution uniform, no precipitation was qualified.
4.7 Low temperature stability test
According to GB/T 19137-2003 "on emulsions and a homogeneous liquid formulation" in volume to precipitate a solid or oil is no more than 0.3mL qualified.
4.8 Thermal storage stability test
According to GB/T 19136-2003 of "liquid formulation" to. After the thermal storage mass fraction propamocarb hydrochloride should not be lower than the pre-heat storage 95%; the rest of the indicators should remain in line with the requirements of 3.2.
4.9 Product testing and acceptance
Shall comply with GB/T 1604's. Limit numerical processing using rounding value comparison method.
5 Marking, labeling, packaging, storage and transportation
Label 5.1 propamocarb hydrochloride salt agent shall indicate the mass fraction of propamocarb hydrochloride.
Flag 5.2 propamocarb hydrochloride salt agent, labeling and packaging should comply with the provisions of GB 3796.
5.3 propamocarb hydrochloride salt water available within the plug and cover with a polyester bottle, net content of 200mL, 1000mL etc; outsourcing Fitted with corrugated boxes or plastic boxes, each containing a net capacity not exceeding 20000mL. Also available upon request or order agreement, the use of other forms of Packaging, but to comply with the provisions of GB 3796.
5.4 propamocarb hydrochloride salt water package should be stored in ventilated, dry warehouse, stacked manner consistent with safe, convenient handling principles.
5.5 storage, prevent moisture and sunlight, to avoid infiltration of ground; no food, beverages, animal feed-mixing; avoid contact with skin, eye contact Touch, mouth and nose to prevent inhalation.
5.6 Security. propamocarb hydrochloride salt water is a toxic fungicide harmful. When used, should wear protective gloves, masks, wear dry Net protective clothing immediately after use with soap and water. The agent contact with skin, wash immediately with soap and water; if splashed into the eyes, should Rinse immediately with plenty of water; consult a doctor if necessary. If swallowed, do not induce vomiting, consult a doctor, mouth and drink plenty of water, clothes Activated carbon.
5.7 Warranty. Under the provisions of storage and transportation conditions, warranties of propamocarb hydrochloride salt agent two years from date of manufacture.
Appendix A
(Informative)
Methods (CIPAC method) was measured by liquid chromatography propamocarb hydrochloride salt mass fraction A. 1 Method summary + Water sample was dissolved in methanol, + water + ammonia water as the mobile phase, to use as a filler Si100 stainless steel column and ultraviolet detection Detector, sample the propamocarb hydrochloride HPLC separation and determination.
A. 2 Reagents and solutions Methanol. HPLC grade;
Water. The new secondary steam distilled water;
Ammonia solution. 25% (mass fraction);
A mixed solution. [Psi] (methanol. water) = 80.20;
Propamocarb hydrochloride (propamocarb) standard. a known mass fraction >=99.0%.
A. 3 Instrument
LC. a variable wavelength UV detector and quantitative injection valve;
Chromatographic data processor or chromatography workstation;
Column. LichrosorbSi100,250mm × 4mm (. I.d), 5µm stainless steel column (column or other equivalent effect);
Filter. pore size of about 0.45µm;
Micro injector. 50µL.
A. 4 HPLC operating conditions Mobile phase. [Psi] (methanol. water. aqueous ammonia) = 800.192.8;
The mobile phase flow rate. 1.0mL/min;
Column temperature. room temperature (temperature change should not exceed 2 °C);
Detection wavelength. 210nm;
Injection volume. 10µL;
Retention time. propamocarb about 7.4min.
HPLC operating conditions described above, the Department of typical operating parameters. According to the characteristics of different instruments, given operating parameters adjusted as appropriate, in order to obtain the best results. Typical liquid chromatography is shown in Figure propamocarb hydrochloride salt agent A. 1.
1 --- propamocarb.
Figure A. Figure 1 HPLC propamocarb hydrochloride salt agent
A. 5 measuring step
A. 5.1 preparation of standard solution Accurately weigh approximately 0.175g (accurate to 0.0002g) of propamocarb hydrochloride standard sample in 100mL volumetric flask, dissolved with a mixed solution Solution, and set the volume to the mark, shake spare.
A. 5.2 Sample preparation solution Accurately weighed sample containing about taking propamocarb hydrochloride 0.2g (accurate to 0.0002g), and placed in 100mL flask, with a mixed solution Dissolve and dilute to the mark, shake spare. Through 0.45µm membrane filter and set aside.
A. 5.3 Determination Under the above chromatographic operating conditions, after the instrument is stable, continuous injection of several doses of the standard solution until the two adjacent needles propamocarb relative peak area After the change of less than 1.5%, according to the solution, sample solution, sample solution, standard order of standard solution was measured.
A. 6 Calculation
The two doses of the standard solution of two injections of the sample solution and measured before and after the sample solution propamocarb peak areas are averaged. Cream sample the mass fraction of propamocarb hydrochloride 1 (%) according to equation (A.1) (standard when propamocarb hydrochloride) or formula (A.2) (standard of propamocarb time) were Calculate the mass concentration rho propamocarb hydrochloride (g/L) according to formula (A.3) calculated as follows.
Where.
A1 --- the standard solution, the average propamocarb peak area;
A2 --- sample solution, the average propamocarb peak area;
224.7 --- molecular weight propamocarb hydrochloride;
188.3 --- propamocarb molecular weight;
--- Standard samples propamocarb (propamocarb hydrochloride) mass fraction, expressed as a percentage;
A. 7 allowable difference the relative deviation of two parallel determination results shall not be greater than ± 2%, whichever is the arithmetic mean as a measurement result.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 1601Determination method of pH value for pesticides
- GB/T 1604Commodity pesticide regulations for acceptance
- GB/T 1605-2001Sampling method for commodity pesticides
- GB 3796General rule for packing of pesticides
- GB/T 4472Detemination of density and relative density for chemical products
- GB/T 19137-2003Testing method for the storage stability at low temperature of pesticides
How to Download GB 22622-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 3796-2018 — General rule for packing of pesticides
GB/T 1601-2023 — Determination method of pH value for pesticides
GB/T 1604-2025 — Commodity pesticide regulations for acceptance
Secure payment via Stripe
Payments accepted
GB 22622-2008
$135.00