Scope
GB 22606-2008 is the English-translated version of 莠去津原药.
GB 22606-2008 — This standard specifies requirements for atrazine original drug, test methods and marking, labeling, packaging, storage and transportation. This standard applies to atrazine by the impurity generated in the production and composition of atrazine original drug.
Found what you need?
Document preview — GB 22606-2008
National Standard of the People's Republic of China
- ICS
- 65.100.20
- Classification
- G 25
Issued by: Standardization Administration of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Requirements
- 4.1 Sampling
- 4.2 Identification Test
- 4.3 Determination of the mass fraction of atrazine
- 4.4 Determination of loss on drying
- 4.5 Determination of dimethylformamide two insolubles
- 4.6 Product testing and acceptance
- 5 Marking, labeling, packaging, storage and transportation
Foreword
The standard Chapter 3, Chapter 5 is mandatory, the rest are recommended.
Appendix A of this standard is the data appendix.
Since the implementation of this standard, the original industry standard HG2216-1991 "atrazine original drug" void.
The standard proposed by China Petroleum and Chemical Industry Association.
This standard by the National Standardization Technical Committee on Pesticides (SAC/TC133) centralized.
1 Scope
This standard specifies requirements for atrazine original drug, test methods and marking, labeling, packaging, storage and transportation.
This standard applies to atrazine by the impurity generated in the production and composition of atrazine original drug.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 1604 Goods pesticide regulations for acceptance GB/T 1605-2001 Sampling Method commercial pesticides GB 3796 pesticide packaging General GB/T 19138 Determination of acetone insoluble pesticide
3 Requirements
3.1 Appearance. white to pale yellow solid.
3.2 atrazine original drug should be consistent with the requirements in Table 1.
Table 1 Atrazine original drug control project indicators
Item Index
Atrazine mass fraction /% >= 95.0 Drying loss mass fraction /% <= 0.8 Dimethylformamide insoluble matter mass fraction a /% <= 0.5 a dimethylformamide insolubles content under normal production conditions, every 3 months test at least once.
Test Method 4
4.1 Sampling
According to GB/T 1605-2001 "on commercial pesticides sampling method". Determining sample package using a random number table method; the final sample the amount of not less than 100g.
4.2 Identification Test
Gas Chromatography --- The identification test can be carried out simultaneously with the determination of the mass fraction of atrazine. Under the same chromatographic operating conditions, the test Retention time with the standard solution of a sample solution peaks in atrazine chromatographic retention time, the relative difference should be less than 1.5%.
Infrared spectroscopy --- sample and standard samples in 4000cm-1 ~ 400cm-1 wave number range of the infrared spectrum should be no significant difference different. Atrazine Sample standard infrared spectrum shown in Figure 1.
Figure 1 atrazine standard infrared spectrum
4.3 Determination of the mass fraction of atrazine
4.3.1 Method summary
Sample was dissolved in chloroform to triadimefon as internal standard, the use of the inner wall of the bonded Carbowax 20M capillary column and flame Ionization detector to sample atrazine gas chromatographic separation and determination. You can also use packed column gas chromatography, chromatographic conditions Senate See Appendix A.
4.3.2 Reagents and solutions
Chloroform;
Triadimefon. >=95%, should not interfere with the analysis of impurities;
Atrazine Sample. Atrazine is known mass fraction >=99.0%;
Internal standard solution. Weigh 6.8g triadimefon, placed 1000mL volumetric flask with chloroform to dissolve and dilute to volume, shake.
4.3.3 Instruments
Gas chromatograph. with a hydrogen flame ionization detector;
Chromatographic data processor or chromatography workstation;
Column. 30m × 0.32mm (i.d.) Double capillary column, wall-bonded polyethylene glycol 20M, film thickness 0.25µm;
Micro injector. 10µL.
4.3.4 GC operating conditions
Temperature (°C) Temperature. 195 gasification chamber. 230, detection chamber. 230;
Gas flow rate (mL/min). carrier gas (N2) 2.0, hydrogen gas 30, air 300;
Injection volume (µL). 1.0;
Retention time (min). atrazine about 4.2, internal standard (triadimefon) about 6.0.
1 --- atrazine;
2 --- internal standard (triadimefon).
Figure 2 Atrazine gas chromatogram Jin original drug and the internal standard
GC operating conditions described above, the Department of typical operating parameters. According to the characteristics of different instruments, given operating parameters adjusted as appropriate, in order to obtain the best results. Typical atrazine original drug and the internal standard gas chromatography is shown in Figure 2.
4.3.5 Measuring step
4.3.5.1 Preparation of standard solution
Weigh atrazine standard 0.1g (accurate to 0.0002g), placed in 15mL stoppered glass bottle with a pipette moved 10mL internal standard Solution, shake.
4.3.5.2 Preparation of the sample solution
Weigh about containing herbicide atrazine 0.1g sample of (accurate to 0.0002g), placed in 15mL stoppered glass bottle, in use with 4.3.5.1 with a pipetted into internal standard solution 10mL, shake.
4.3.5.3 Determination
Under these operating conditions, the instrument until a stable baseline, the number of continuous injection doses of the standard solution, calculated for each needle atrazine and the internal standard peak area when the ratio of repeatability, two needles herbicide atrazine to be adjacent to the internal standard peak area ratio of the relative change of less than 1.5%, according to the standard solution, sample Solution, sample solution, the order of the standard solution was measured.
4.3.6 Calculation
The two needle sample solution and measured before and after the two doses of the standard sample solution of atrazine and the internal standard peak area ratio of the average, respectively.
Atrazine sample mass fraction of 1 (%), according to equation (1).
Where.
--- Atrazine standard mass fraction, expressed as a percentage.
4.3.7 Allowable difference
The difference between two parallel determination results shall not be greater than 1.5%, the arithmetic mean value as a measurement result.
4.4 Determination of loss on drying
4.4.1 Instruments
Weighing bottle. diameter 50mm, height 30mm;
Oven. (105 ± 5) °C;
Dryer.
4.4.2 Measuring step
The weighing bottle placed in an oven bake 1h, cooled to room temperature and placed out, weighed (accurate to 0.0002g) in a desiccator. Repeat the above steps Step, until constant weight weighing bottle. 10g sample was taken has been drying to constant weight weighing bottle, paving, weighed (accurate to 0.0002g), weighed Bottles and caps separately placed in an oven, bake for 1h, cover, take out into the dryer to cool to room temperature, weighed (accurate to 0.0002g).
4.4.3 Calculation
Expressed as a percentage by mass loss on drying 2 (%) according to equation (2).
100 (2)
Where.
4.5 Determination of dimethylformamide two insolubles
According to GB/T 19138 performed. Using dimethylformamide solvent.
4.6 Product testing and acceptance
Shall comply with GB/T 1604's. Treatment of extreme values using the rounding value comparison method.
5 Marking, labeling, packaging, storage and transportation
Flag 5.1 atrazine original drug, labeling and packaging should comply with the provisions of GB 3796.
5.2 atrazine original drug application of clean, lined with plastic woven bag, net weight 25kg.
5.3 According to user requirements or ordering agreement, you can use other forms of packaging, it should comply with the provisions of GB 3796.
5.4 The package should be stored in well-ventilated, dry coffers.
5.5 storage, prevent moisture and sunlight, no food, seed, feed mix, avoid contact with skin, eyes, mouth and nose to prevent inhalation.
5.6 security. low toxicity herbicide atrazine. The FDA should wear protective gloves. Nose and mouth to prevent inhalation, or skin contact with exposed parts of the body the goods should be promptly washed with soap and water. In case of poisoning should promptly consult a doctor.
5.7 of acceptance. Acceptance of atrazine original drug for a month. From the date of delivery, the quality of the finished product acceptance within one month, the indicators shall comply with the requirements of this standard.
Appendix A
(Informative)
Atrazine quality gas chromatographic method scores packed column A. 1 Method summary Sample was dissolved in chloroform to triadimefon as internal standard, using polyethylene glycol 20M/GasChromQ packed column and flame Ionization detector to sample atrazine gas chromatographic separation and determination.
A. 2 Reagents and solutions Chloroform;
Triadimefon. >=95%, should not interfere with the analysis of impurities;
Atrazine Sample. Known atrazine content, >=99.0%;
Internal standard solution. Weigh 10.0g of triadimefon, placed 1000mL volumetric flask with chloroform to dissolve and dilute to volume, shake.
A. 3 Instrument
Gas chromatograph. with a hydrogen flame ionization detector;
Chromatographic data processor or chromatography workstation;
Column. 3% polyethylene glycol 20M/GasChromQ (80 mesh to 100 mesh) stainless steel column (column or glass);
Micro injector. 10µL.
A. 4 GC operating conditions Temperature (°C). Column temperature 200 ± 5, the gasification chamber 230, the detector chamber 230;
Gas flow rate (mL/min). carrier gas (N2) 80.0, the hydrogen gas 40, air 400;
Injection volume (µL). 1.0;
Retention time (min). atrazine about 4.6, about 7.4 internal standard.
GC operating conditions described above, the Department of typical operating parameters. According to the characteristics of different instruments, given operating parameters adjusted as appropriate, in order to obtain the best results. Typical atrazine original drug and the internal standard packed column gas chromatography is shown in Figure A. 1.
1 --- atrazine;
2 --- internal standard (triadimefon).
Figure A. 1 atrazine original drug and the internal standard packed column gas chromatogram
A. 5 measuring step
A. 5.1 preparation of standard solution Weigh atrazine standard 0.1g (accurate to 0.0002g), placed in 15mL stoppered glass bottle with a pipette accurately transferred to 10mL Internal standard solution, and shake.
A. 5.2 Sample preparation solution Weigh about containing herbicide atrazine 0.1g sample of (accurate to 0.0002g), placed in 15mL stoppered glass vial, with A. 5.1 used with a pipette accurately transferred to the internal standard solution 10mL, shake.
A. 5.3 Determination Under these operating conditions, the instrument until a stable baseline, the number of continuous injection doses of the standard solution, calculated for each needle atrazine and the internal standard peak area when the ratio of repeatability, two needles herbicide atrazine to be adjacent to the internal standard peak area ratio of the relative change of less than 1.5%, according to the standard solution, sample Solution, sample solution, the order of the standard solution was measured.
A. 6 Calculation
The peak area of the two-pin and the sample solution is measured before and after the two doses of the standard sample solution atrazine and internal standard ratios are averaged.
Atrazine sample mass fraction of 1 (%) according to equation (A.1) Calculated.
Where.
--- Atrazine standard mass fraction, expressed as a percentage.
A. 7 allowable difference the difference between two parallel determination results shall not be greater than 1.5%, the arithmetic mean value as a measurement result.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.
Referenced standards
How to Download GB 22606-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 3796-2018 — General rule for packing of pesticides
GB/T 1604-2025 — Commodity pesticide regulations for acceptance
GB/T 1605-2001 — Sampling method for commodity pesticides
Secure payment via Stripe
Payments accepted
GB 22606-2008
$135.00