GB 20041.23-2009Conduit systems for cable management -- Part 23: Particular requirement -- Flexible conduit systems (English PDF)
电缆管理用导管系统 第23部分:柔性导管系统的特殊要求
This is a limited preview
Buy now to download the full PDF (10 pages)
Need quotation for your management?
Get a formal quotation for GB 20041.23-2009 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Mandatory
Issue date
May 6, 2009
Implementation date
February 1, 2010
Scope
GB 20041.23-2009 is the English-translated version of 电缆管理用导管系统 第23部分:柔性导管系统的特殊要求.
GB 20041.23-2009 — GB/T 20041.1-2005 after this chapter apply for the following modifications. increase. This part of GB 20041 specifies the requirements for flexible conduit systems.
Found what you need?
Document preview — GB 20041.23-2009
National Standard of the People's Republic of China
- ICS
- 29.120.10
- Classification
- K 65
Issued by: Standardization Administration of China
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Definitions
- 4 1 General requirements
- 5 General conditions for test
- 6 Category
- 7 Marking and documentation
- 8 Size
- 9 Structure
- Mechanical properties 2
- 11 Electrical Performance
- 12 Thermal Performance
- 13 Flame Effect
- 14 3 External influences
- 15 3 Electromagnetic Compatibility
- Appendix A (normative) Catheter System classification code
- Material thickness measurement Appendix B (normative)
Foreword
All technical content in this section is mandatory.
GB 20041 "Conduit systems for cable management" is divided into two parts.
--- Part 1. General requirements (GB/T 20041.1)
--- Part 2. Particular requirements (GB 20041.21 ~ 20041.24) - Part 21. Particular requirements for rigid conduit systems - Part 22. Particular requirements for flexible conduit systems - Part 23. Particular requirements for flexible conduit systems - Part 24. Particular requirements for conduit systems buried underground this is Part 23 of GB 20041. This section should be GB/T 20041.1-2005 used in conjunction.
This section identical with IEC 61386-23:2002 (first edition) "Conduit systems for cable management - Part 22. flexible conduit special Claim".
This section of the Appendix A, Appendix B is a normative appendix.
This part is proposed by the China Electrical Equipment Industrial Association.
This part of the National Standardization Technical Committee electrical accessories.
This section drafted by. China Electric Apparatus Research Institute, Guangdong CIQ, Foshan Gaoming Gu Plastic Co., Ltd. in Hangzhou Hongyan Electric Co., Ltd., Guangdong Science and Technology Industrial Co., Ltd. Liansu.
1 Scope
GB/T 20041.1-2005 after this chapter apply for the following modifications.
increase.
This part of GB 20041 specifies the requirements for flexible conduit systems.
2 Normative references
The following documents contain provisions which, through reference in this text, constitute provisions of this part. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this section, however, encourage the parties to this part of the research agreement Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this section.
GB/T 20041.1-2005 this chapter apply.
3 Definitions
GB/T 20041.1-2005 this chapter apply.
4 General requirements
GB/T 20041.1-2005 this chapter apply.
5 General conditions for tests
GB/T 20041.1-2005 this chapter apply.
Category 6
Except as follows, GB/T 20041.1-2005 this chapter apply.
6.1.31), 6.1.32) and 6.1.33) Not applicable.
7 Marking and documentation
GB/T 20041.1-2005 after this chapter apply for the following modifications.
increase.
7.1.101 conduit should be identified in accordance with the requirements of 7.1. Logo should at regular intervals along the full length of the catheter, as the most suitable interval 1m, not more than 3m. As in the case of technology can not be implemented, logos can be marked on the label attached to the end product or packaging.
Compliance is checked by inspection.
7.1.102 The manufacturer shall provide documentation for the system or marked on the package, to illustrate the minimum diameter, minimum bend radius and in accordance with Chapter 6 classification.
Compliance is checked by inspection.
Size 8
instead.
GB 20041.23-2009/IEC 61386-23:2002
8.1 Threads shall comply with GB/T 17194.
Compliance is checked by measuring gauge GB/T 17194 stipulated to check.
The minimum inner diameter of 8.2 catheter system shall be declared by the manufacturer.
Compliance is checked by measurement.
9 Structure
GB/T 20041.1-2005 this chapter apply.
10 Mechanical properties
GB/T 20041.1-2005 after this chapter apply for the following modifications.
10.1 Mechanical strength
10.1.1 Addition.
Note. very light, flexible catheter should not be considered to have sufficient mechanical protection, and should not be used in building construction.
10.4 Bending test
GB/T 20041.1-2005 this section does not apply.
10.5 Bending test
10.5.101 from conduit terminating conduit fittings with the composition of the components according to the manufacturer's instructions assembled, you should use 101 as shown in Fig.
Means for bending test.
10.5.102 test should be used as a conduit 6 samples having a suitable length, three specimens should be minimum transport, use and safety provisions in Table 1 Means test temperature ± 2 °C under. Further three samples shall be carried out in Table 2 below the specified maximum transport, use and installation temperature ± 2 °C in test.
Manufacturers can declare a flexible catheter adapted to a predetermined temperature in accordance with Table 1 transport and installation, but only for a minimum temperature of ambient temperature Bending degree, this time, the test shall be at (20 ± 2) °C were, classification code and the first three digits should be X. The manufacturer shall, in its written materials the transport and installation explicitly stated minimum temperature according to Table 1, the lowest temperature of the ambient temperature and the maximum temperature in accordance with the installation and use
Table 2.
10.5.103 terminating conduit fittings should be used as shown in Fig. 101 is fixed to the specimen swing body, when the catheter is moved to the middle position, the catheter Axis is vertical, and passing through the pivot shaft. Equipped with a device should be placed after the sample under specified conditions 2h, or until the sample temperature reaches declaration Degree, whichever is longer.
10.5.104 pendulum should axis vertical axis, swing, swing the total angle of (180 ± 5) °, the average separated by a vertical axis. Components should be Per minute (40 ± 5) times the rate of 5000 fold. From the vertical position start, once a week sinusoidal movement bent.
10.5.105 After the test, the sample should be no signs of split, nor come now without additional amplification normal or corrected vision visible crack.
10.6-destructive testing GB/T 20041.1-2005 this section does not apply.
10.7 Tensile strength
GB/T 20041.1-2005 purpose of this regulation for the following modifications apply.
10.7.3 Replacement.
For no statement has a tensile strength of the catheter system, the tensile strength of the interface should be in accordance with Table 6 Classification 1.
11 Electrical Performance
GB/T 20041.1-2005 after this chapter apply for the following modifications.
11.2 shield ground test.
instead.
GB 20041.23-2009/IEC 61386-23:2002 Catheter samples and terminating conduit fittings shall be specified by the manufacturer and the fixed assembly shown in Figure 103. Components shall pass to 25Aa. c.
Current 60 + 5 0s, current frequency is 50Hz ~ 60Hz, no-load voltage of the power supply does not exceed 12V. Then measured between two o'clock as shown in Fig. 103 Voltage drop, and drop resistance is calculated from the current and voltage.
Resistance not exceeding 0.05ohm.
If you require special devices to connect with the conduit and conduit fittings, these devices should be sufficient to remove the protective coating of the catheter, or should be manufactured Suppliers provision would remove the protective layer.
12 Thermal Performance
GB/T 20041.1-2005 after this chapter apply for the following modifications.
12.2.4 Replacement.
Then, the load removed, the sample was immediately placed in the vertical direction, so that on the basis of 102 corresponding to the gauge in its own weight and without any the case of the initial velocity through the conduit, should be able to gauge catheter.
13 Flame effect
GB/T 20041.1-2005 this chapter apply.
14 External influences
GB/T 20041.1-2005 this chapter apply.
15 Electromagnetic Compatibility
GB/T 20041.1-2005 this chapter apply.
GB 20041.23-2009/IEC 61386-23:2002 Drawings.
A --- catheter;
B --- Termination accessories;
Minimum bend radius Y --- declared by the manufacturer;
Z --- 1.5 × Y.
1 --- pendulum;
2 --- guide support block;
3 --- a plan view of the guide support block.
Note. The design of this figure can not be limited, subject to the icon size requirements.
101 bending test apparatus of FIG.
GB 20041.23-2009/IEC 61386-23:2002 D manufacturer declares that 80% of the minimum inner diameter of the catheter Steel materials, hard and polished edges slightly thrown round Manufacturing tolerances +0.05 0 mm Tolerance and axial dimensions ± 0.2mm Allow wear 0.01mm Note. The figure in addition to the rest of the dimensions shown without design limitations.
Figure 102 checks a minimum inner diameter of the catheter gauge after the impact and the heat test
Drawings.
X = 12mm ± 2mm
1 --- 3mm metal plate;
2 --- optional locking nut;
3 --- By tapping hole or threaded fitting nut to split termination conduit fitting plate;
4 --- catheter.
103 Shield ground test conduit and conduit fittings termination assembly GB 20041.23-2009/IEC 61386-23:2002 Appendix A (Normative) Catheter system of classification codes Part 1 of this Appendix apply.
Appendix B
(Normative)
Determination of material thickness Part 1 of this Appendix apply.
GB 20041.23-2009/IEC 61386-23:2002
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.
Referenced standards
How to Download GB 20041.23-2009
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 20041.21-2008 — Conduit systems for cable management -- Part 21: Particular requirement for rigid conduit systems
GB 20041.22-2009 — Conduit systems for cable management -- Part 22: Particular requirement -- Pliable conduit systems
GB 20041.24-2009 — Conduit systems for cable management -- Part 24: Particular requirement -- Conduit systems buried underground
Secure payment via Stripe
Payments accepted
GB 20041.23-2009