Superseded

GB 19043-2013Minimum allowable values of energy efficiency and the energy efficiency grades of double-capped fluorescent lamps for general lighting service (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (6 pages)

Need quotation for your management?

Get a formal quotation for GB 19043-2013 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China

Level / Type

National · Mandatory

Issue date

June 9, 2013

Implementation date

October 1, 2013

Scope

GB 19043-2013 (Minimum allowable values of energy efficiency and the energy efficiency grades of double-capped fluorescent lamps for general lighting service) is available as an English-translated PDF.

GB 19043-2013 — This Standard specifies the energy efficiency grades, energy efficiency limits, evaluation values of energy conservation, and test methods of double-capped fluorescent lamps for general lighting service (Hereinafter referred to as. double-capped fluorescent lamps).

This Standard applies to the following two operating types of lamps. preheating cathode lamp that can work in AC power supply frequency lines with starter, and can work in high frequency lines; and preheating cathode lamp that can work in high frequency lines.

Found what you need?

Document preview — GB 19043-2013

National Standard of the People's Republic of China

ICS
27.010
Classification
F 01

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China

Contents

  • 1 Scope...4
  • 2 Normative references...4
  • 3 Terms and definitions...4
  • 4 Technical requirements...5
  • 5 Test methods...6

Foreword

The provisions in 4.3 of the Standard are mandatory; the rest are recommended.

This Standard is drafted according to the rules specified in GB/T 1.1-2009.

This Standard replaces GB 19043-2013 Minimum Allowable Values of Energy Efficiency and the

Energy Efficiency Grades of Double-capped Fluorescent Lamps for General Lighting Service. In

addition to editorial modification, the main technical changes are as follows, compared with GB

19043-2013.

— Modify the scope of the Standard;

— Delete the technical requirements for minimum allowable values of energy efficiency for

double-capped fluorescent lamps;

— Increase the initial luminous efficacy values of each energy efficiency grade of double-capped

fluorescent lamps;

— Delete the inspection rules.

This Standard was proposed by Resource Conservation and Environmental Protection Division of

National Development and Reform Commission, and Energy Saving and Comprehensive Utilization

Division of Ministry of Industry and Information Technology.

This Standard shall be centralized by National Energy Basis and Management Standardization

Technical Committee (SAC/TC 20).

Main drafting organizations of this Standard. China National Institute of Standardization, Beijing

Lighting Research Institute, Osram (China) Lighting Co., Ltd., Shanghai Institute of National Lighting

Quality Supervision and Inspection Center, Panasonic Lighting (Beijing) Co., Ltd., Zhejiang Yankon

Group Co., Ltd., Philips Lighting Industry (China) Co., Ltd., Shanghai Yaming Lighting Co., Ltd.,

Zhejiang Chenhui Lighting Co., Ltd., and Zhejiang Shenghui Lighting Co., Ltd..

Main drafters of this Standard. Liang Xiuying, Zhao Yuejin, Zhang Junbin, Wang Lihong, Yu Anqi,

Chen Yiping, Liu Shijun, Huang Zhengyong, Guo Pengxin, Zhou Yufei, and Lu Guangming.

The previous version of the Standard is as follows.

— GB 19043-2013.

Minimum allowable values of energy efficiency and the energy efficiency grades

of double-capped fluorescent lamps for general lighting service

1 Scope

This Standard specifies the energy efficiency grades, energy efficiency limits, evaluation values of

energy conservation, and test methods of double-capped fluorescent lamps for general lighting

service (Hereinafter referred to as. double-capped fluorescent lamps).

This Standard applies to the following two operating types of lamps. preheating cathode lamp that

can work in AC power supply frequency lines with starter, and can work in high frequency lines; and

preheating cathode lamp that can work in high frequency lines.

2 Normative references

The articles contained in the following documents have become part of this Standard when they are

quoted herein. For the dated documents so quoted, all the modifications (Including all corrections) or

revisions made thereafter shall be applicable to this Standard.

GB/T 10682 Double-capped fluorescent lamps - Performance specifications

GB 18774 Double-capped fluorescent lamps - Safety specifications

3 Terms and definitions

For the purpose of this Standard, those defined in GB/T 10682 AND the following terms and

definitions apply to this document.

3.1

Initial luminous efficacy for double-capped fluorescent lamps

Under the standard test conditions, the ratio of measured initial luminous flux of double-capped

fluorescent lamps AND the power, in the units of lm/W.

3.2

Minimum allowable values of energy efficiency for double-capped fluorescent lamps

Under the standard test conditions, the minimum standard value to which the initial luminous efficacy

of the double-capped fluorescent lamps shall reach.

3.3

Evaluating values of energy conservation for double-capped fluorescent lamps

39 High luminous flux series 6730 74 71 67 79 75 71

49 High luminous flux series 6750 82 79 75 88 84 79

54 High luminous flux series 6840 77 73 67 82 78 72

80 High luminous flux series 6850 72 69 63 77 73 67

7220 81 75 66 87 80 75

23 7222 84 77 76 89 86 85

32 7420 97 89 78 104 95 84

45 7422 101 93 85 108 99 90

4.3 Minimum allowable values of energy efficiency and lumen maintenance of double-capped

fluorescent lamps

The minimum allowable values of energy efficiency for double-capped fluorescent lamps is Grade 3

in Table 1.When it is ignited and lighted for 2000h, its lumen maintenance shall comply with the

relevant provisions of GB/T 10682.

4.4 The energy conservation evaluation value and lumen maintenance of double-capped

fluorescent lamps

The energy conservation evaluation value of double-capped fluorescent lamps is Grade 2 in Table 1.

When it is ignited and lighted for 2000h, its lumen maintenance shall comply with the relevant

provisions of GB/T 10682.

5 Test methods

The initial luminous efficiency, chromaticity coordinates, and lumen maintenance shall be tested in

accordance with the test methods specified in GB/T 10682.

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.

Referenced standards

How to Download GB 19043-2013

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
6 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 19043-2013

$65.00