Valid

GB 1886.353-2021National Food Safety Standard - Food Additive - gamma-cyclodextrin (English PDF)

Also coversGB1886.353-2021

Open the GB 1886.353-2021 preview as PDF

Preview — first pages of GB 1886.353-2021

This is a limited preview

Buy now to download the full PDF

Issued by

National Health Commission; State Administration for Market Regulation

Level / Type

National · Mandatory

Issue date

September 7, 2021

Implementation date

March 7, 2022

Scope

GB 1886.353-2021 (National Food Safety Standard - Food Additive - gamma-cyclodextrin) is available as an English-translated PDF.

GB 1886.353-2021 — This Standard applies to the food additive gamma-cyclodextrin that is prepared by enzymatic hydrolysis and extraction of starch.

Document preview — GB 1886.353-2021

National Standard of the People's Republic of China

Issued by: National Health Commission; State Administration for Market Regulation

Contents

  • 1 Scope3
  • 2 Molecular formula and relative molecular mass3
  • 3 Technical requirements3
  • Appendix A Inspection method5

1 Scope

This Standard applies to the food additive gamma-cyclodextrin that is prepared by enzymatic hydrolysis and extraction of starch.

2 Molecular formula and relative molecular mass

2.1 Molecular formula

(C6H10O5)8

2.2 Relative molecular mass

1297.13 (according to the international relative atomic mass in 2018)

3 Technical requirements

3.1 Sensory requirements

Sensory requirements shall meet the requirements of Table 1.

3.2 Physical and chemical indicators

Physical and chemical indicators shall meet the requirements of Table 2.

Appendix A Inspection method

A.1 General provisions The reagents and water used in this Standard refer to analytical reagents and grade-3 water in accordance with GB/T 6682, when other requirements are not indicated. The standard solutions used in the test, the standard solutions for impurity determination, the preparations and products, unless otherwise specified, shall be prepared in accordance with GB/T 601, GB/T 602 and GB/T 603. The solution used in the test refers to an aqueous solution, when it is not specified which solvent is used to prepare it.

A.2 Identification test A.2.1 Specific rotation test Weigh 1.00 g of the sample and dissolve it in 100 mL of water; measure it according to the method that is specified in GB/T 613. The specific rotation shall be +173° ~ +180°.

A.2.2 Chromatographic test In the gamma-cyclodextrin content determination test, the retention time of the main peak of the test solution chromatogram shall be consistent with the retention time of the main peak of the standard solution chromatogram.

A.3 Determination of gamma-cyclodextrin content (on a dry basis)

A.3.1 Reagents and materials A.3.1.1 Methanol: chromatographically pure.

A.3.1.2 Water: Grade-1 water specified in GB/T 6682.

A.3.1.3 gamma-cyclodextrin standard substance: purity >=98.0%.

A.3.2 Instruments and equipment High performance liquid chromatograph: equipped with a refractive index detector.

A.3.3 Reference chromatographic conditions A.3.3.1 Chromatographic column: C18, C8, phenyl column or other reverse chromatographic columns (5 um, 150 mm x 4.6 mm).

A.3.3.2 Mobile phase: water: methanol = 93: 7, if necessary, it can be adjusted.

A.3.3.3 Column temperature: 30 °C.

A.3.3.4 Detector temperature: 40 °C.

A.3.3.5 Flow rate: 1.0 mL/min.

A.3.3.6 Injection volume: 20 uL.

A.3.4 Analysis steps A.3.4.1 Preparation of standard solution Accurately weigh an appropriate amount of gamma-cyclodextrin standard product (on a dry basis, refer to Method 1 in GB 5009.3-2016 for the drying method); add water to dissolve; dilute to a standard solution of a concentration of about 1.0 mg/mL (on a dry basis). Use a 0.45 um microporous membrane for filtration before chromatographic analysis.

A.3.4.2 Preparation of analytical stock solution Accurately weigh 250 mg of the sample (on a dry basis, refer to Method 1 in

GB 5009.3-2016 for the drying method); put it in a 25 mL measuring flask; add water to dissolve it; take it out; let it cool; use water to dilute to the mark.

A.3.4.3 Preparation of analytical solution Precisely pipette 5.0 mL of analytical stock solution; place it in a 50.0 mL measuring flask; use water to dilute to the mark.

A.3.4.4 Preparation of system suitability solution Accurately weigh an appropriate amount of gamma-cyclodextrin standard substance (on a dry basis, refer to Method 1 in GB 5009.3-2016 for the drying method);

add water to dissolve; obtain a gamma-cyclodextrin solution of a concentration of about 0.5 mg/mL.

A.3.4.5 System suitability test Under the reference chromatographic conditions of A.3.3, respectively determine the standard solution and sample solution. The system suitability means that, for 5 repeated injections of the standard solution, the relative standard deviation of the response area obtained is less than 2.0%.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

How to Buy GB 1886.353-2021

  1. 1Add to cart. Click the "Buy GB 1886.353-2021" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 1886.353-2021

$95.00

$80.00for partners