GB 16174.1-2015Implants for surgery—Active implantable medical devices—Part 1: General requirements for safety, marking and for information to be provided by the manufacturer (English PDF)
手术植入物 有源植入式医疗器械 第1部分:安全、标记和制造商所提供信息的通用要求
Also coversGB16174.1-2015
This is a limited preview
Buy now to download the full PDF
Need quotation for your management?
Get a formal quotation for GB 16174.1-2015 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China
Level / Type
National · Mandatory
Issue date
December 10, 2015
Implementation date
July 1, 2017
Scope
GB 16174.1-2015 is the English-translated version of 手术植入物 有源植入式医疗器械 第1部分:安全、标记和制造商所提供信息的通用要求.
GB 16174.1-2015 — This document specifies requirements that are generally applicable to active implantable medical devices. This document is applicable to active implantable medical devices that are electrically powered and powered by other energy sources (for example by gas pressure or by springs), as well as to some non-implantable parts and accessories of the active implantable medical devices. Note 1.For particular types of active implantable medical devices, these general requirements are supplemented or modified by the requirements of particular parts. The tests that are specified in this document are type tests and are to be carried out on samples of an active implantable medical device to show compliance. Note 2.The device that is commonly referred to as an active implantable medical device can be a single device, a combination of devices, or a combination of a device or devices and one or more accessories. Not all of these parts are required to be either partially or totally implantable, but there is a need to specify some requirements of non-implantable parts and accessories if they could affect the safety or performance of the implantable device.
Found what you need?
Document preview — GB 16174.1-2015
National Standard of the People's Republic of China
- ICS
- 11.040.40
- Classification
- C30
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China
Contents
- Foreword...4
- Introduction...7
- 1 Scope...8
- 2 Normative references...8
- 3 Terms and definitions...9
- 4 Symbols and abbreviations...17
- 5 General requirements for active implantable medical devices...17
- 6 Requirements for particular active implantable medical devices...20
- 7 General arrangement of the packaging...20
- 8 General markings for active implantable medical devices...20
- 9 Markings on the sales packaging...21
- 10 Construction of the sales packaging...23
- 11 Markings on the sterile pack...24
- 12 Construction of the non-reusable pack...25
- 13 Markings on the active implantable medical device...25
Foreword
This document was drafted in accordance with the rules given in GB/T 1.1-2020,
Directives for standardization - Part 1.Rules for the structure and drafting of
standardizing documents.
This document is Part 1 of GB 16174, Implants for surgery - Active implantable medical
devices. The following parts have been published under GB 16174.
-- Part 1.General requirements for safety, marking and for information to be
provided by the manufacturer;
-- Part 2.Cardiac pacemakers.
This document replaces GB 16174.1-2015 Implants for surgery - Active implantable
medical devices - Part 1.General requirements for safety, marking and for information
to be provided by the manufacturer. Compared with GB 16174.1-2015, in addition to
structural adjustments and editorial changes, the main technical changes are as follows.
-- Change terms and definitions (see Clause 3; Clause 3 of the 2015 edition);
-- Add general requirements for software (see 5.2);
-- Add usability of non-implantable parts (see 5.3);
-- Add data security and protection from harm caused by unauthorized
information tampering (see 5.4);
-- Add general requirements for risk management (see 5.5);
-- Add misconnection of parts of the active implantable medical device (see 5.6);
-- Add requirements for human blood or human plasma, and the authorized
representative from the sales packaging (see 9.12, 9.14);
-- Change the requirements for particle release (see 14.2; 14.2 of the 2015
edition);
-- Change the requirements for electric neutrality (see 16.2; 16.2 of the 2015
edition);
-- Add requirements for active implantable medical device intended to supply
heat (see 17.2);
-- Add requirements for the active implantable medical device that is intended
to use a transcutaneous energy transfer system (see 19.6);
-- Change the requirements for the exposure test to diagnostic levels of
ultrasonic energy (see 22.1; Clause 22 of the 2015 edition);
-- Add requirements for wearing an active implantable medical device for an
MRI procedure (see 22.2);
-- Change the test of the implantable connectors (see 23.6; 23.6 of the 2015
edition);
-- Add the mechanical shock test (see 23.7);
-- Add requirements for accompanying documentation (see 28.24~28.28, 28.30).
This document adopts ISO 14708-1.2014 Implants for surgery - Active implantable
medical devices - Part 1.General requirements for safety, marking and for information
to be provided by the manufacturer by modification.
The technical differences between this document and ISO 14708-1.2014 and their
reasons are as follows.
-- Use the normative reference GB/T 2423.5-2019 to replace IEC 60068-2-
27.2008 (see 23.7) to adapt to our country's technical conditions;
-- Use the normative reference GB/T 2423.43-2008 to replace IEC 60068-2-
47.2005 (see 23.2) to adapt to our country's technical conditions;
-- Use the normative reference GB/T 2423.56-2018 to replace IEC 60068-2-
64.2008 (see 23.2) to adapt to our country's technical conditions;
-- Use the normative reference GB 9706.1-2020 to replace IEC 60601-1.2012
(see 5.1, 15.1, 16.1, 20.1, 23.1, 24.1) to adapt to our country's technical
conditions;
-- Use the normative reference GB/T 7408.1-2023 to replace ISO 8601.2004
(see 9.6, 9.7) to adapt to our country's technical conditions;
-- Use the normative reference GB/T 16886.1 to replace ISO 10993-1 (see 14.3)
to adapt to our country's technical conditions;
-- Use the normative reference GB/T 19633.1 to replace ISO 11607-1 (see 12.1)
to adapt to our country's technical conditions;
-- Use the normative reference GB/T 42062-2022 to replace ISO 14971.2007
(see 5.5) to adapt to our country's technical conditions;
-- Use the normative reference YY/T 0664-2020 to replace IEC 62304.2006 (see
5.2, 19.3) to adapt to our country's technical conditions.
This document also makes the following editorial modifications.
Implants for surgery - Active implantable medical devices -
Part 1.General requirements for safety, marking and for
information to be provided by the manufacturer
1 Scope
This document specifies requirements that are generally applicable to active
implantable medical devices.
This document is applicable to active implantable medical devices that are electrically
powered and powered by other energy sources (for example by gas pressure or by
springs), as well as to some non-implantable parts and accessories of the active
implantable medical devices.
Note 1.For particular types of active implantable medical devices, these general
requirements are supplemented or modified by the requirements of particular
parts.
The tests that are specified in this document are type tests and are to be carried out on
samples of an active implantable medical device to show compliance.
Note 2.The device that is commonly referred to as an active implantable medical
device can be a single device, a combination of devices, or a combination of
a device or devices and one or more accessories. Not all of these parts are
required to be either partially or totally implantable, but there is a need to
specify some requirements of non-implantable parts and accessories if they
could affect the safety or performance of the implantable device.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this
document and are indispensable for its application. For dated references, only the
edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
GB/T 2423.5-2019, Environmental testing - Part 2.Test methods - Test Ea and
guidance. Shock (IEC 60068-2-27.2008, IDT)
GB/T 2423.22-2012, Environmental testing - Part 2.Tests methods - Test N.
Change of temperature (IEC 60068-2-14.2009, IDT)
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2423.5-2019Environmental testing - Part 2: Test methods - Test Ea and guidance: Shock
- GB/T 2423.22-2012Environmental testing - Part 2: Test methods - Test N: Change of temperature
IEC 60068
Cited by
- YY/T 0492-2026Implantable leads
- YY 0989.6-2025Implants for surgery - Active implantable medical devices - Part 6: Particular requirements for active implantable medical devices intended to treat tachyarrhythmia (including implantable defibrillators)
- GB 16174.2-2024Implants for surgery - Active implantable medical devices - Part 2: Cardiac pacemakers
- YY 0989.3-2023Implants for surgery - Active implantable medical devices - Part 3: Implantable neurostimulators
- GB 16174.2-2015Implants for surgery - Active implantable medical devices - Part 2: Cardiac pacemakers
- YY/T 0491-2004Cardiac pacemakers—Low-profile connectors(IS-1) for implantable pacemakers
How to Download GB 16174.1-2015
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 2423.22-2012 — Environmental testing - Part 2: Test methods - Test N: Change of temperature
GB/T 2423.5-2019 — Environmental testing - Part 2: Test methods - Test Ea and guidance: Shock
GB 16174.1-2024 — Implants for surgery - Active implantable medical devices - Part 1: General requirements for safety, marking and for information to be provided by the manufacturer
Secure payment via Stripe
Payments accepted
GB 16174.1-2015
$370.00