Valid

GB 14536.21-2008Automatic electrical controls for household and similar use -- Particular requirements for electrically operated oil valves, including mechanical requirements (English PDF)

家用和类似用途电自动控制器 电动油阀的特殊要求, 包括机械要求

Preview PDF

This is a limited preview

Buy now to download the full PDF (17 pages)

Need quotation for your management?

Get a formal quotation for GB 14536.21-2008 in 30 minutes.

Issued by

Standardization Administration of China

Level / Type

National · Mandatory

Issue date

December 30, 2008

Implementation date

February 1, 2010

Scope

GB 14536.21-2008 is the English-translated version of 家用和类似用途电自动控制器 电动油阀的特殊要求, 包括机械要求.

GB 14536.21-2008 — GB 14536.1 of the chapter, replaced by the following. instead.

1.1 section applies to household and similar devices or electrically operated oil valves used in conjunction with these devices, these devices can use Electricity, gas, oil, solid fuels, such as solar energy or a combination of applications including heating, air conditioning and similar applications.

This section also applies to NTC or PTC thermistor electric valve, which requirements are contained in Appendix J. 1.1.1 This section applies to electrically operated oil valves inherent security for the protection of equipment related to the operating values and operating procedures applicable to home Use and similar equipment or testing with these devices for use with electrical automatic controller.

Also suitable for industrial use, there is no corresponding Standards, such as central heating, air conditioning, electric heat treatment used oil valve. This section also applies to GB 4706.1 involved in various kinds of electric appliances used oil valve.

This section contains the mechanical properties of the oil valve and the valve's electrical performance requirements, both of which will affect the expected operation of the fuel valve.

Note. In this section, the term "device" includes "instrument and control systems." this section does not apply to electric valve oil specifically for industrial equipment.

For non-household equipment generally electrically operated oil valves, and these devices by non-professionals, such as a store or factory or farm use light Also included within the scope of this.

This section describes some of the mechanical characteristics in the "under consideration." Until the mechanical requirements contained in this section, for each country to use this section NOTE. electrically operated oil valves meet the requirements of this section does not indicate that these mechanical features do not require further testing.

1.1.2 This section applies to those manual control when its electrical or mechanical constituting the electric valve. Note. do not belong to a part of the electrically operated oil valves manually switch requirements are contained in the GB 15092.1.

This section does not apply to the nominal size DN150 connection over electric valve. The term "valve" means electrically operated oil valves (including the original actuator and valve assembly).

1.1.3 together with the electric valve to the test laboratory to assess the electric starter in this section. Independent electric starter in GB 14536.16 the assessment of the criteria for the special requirements for electric actuators.

No electrical output 1.1.4 This section applies to a single valve, grouped together as a system of valves and components with the multi-function controller mechanically Valve.

Found what you need?

Document preview — GB 14536.21-2008

National Standard of the People's Republic of China

ICS
29.130.20
Classification
K 32

Issued by: Standardization Administration of China

Contents

  • Introduction
  • IEC Introduction
  • 1 Scope and normative references
  • 2 Definitions
  • 3 4 General Requirements
  • 4 General notes
  • Rating 5
  • 6 Category
  • 6 7 Information
  • 8 8 Protection against electric shock
  • 9 Ground protective measures
  • 10 Terminals and terminations
  • 11 Structural requirements
  • Moisture and dust 12
  • 13 Electric strength and insulation resistance
  • 14 Fever
  • 15 Manufacturing deviation and drift
  • 16 12 Environmental Stress
  • 17 12 Durability
  • Mechanical strength 18
  • 19 Threaded parts and connections
  • 20 Creepage distances, clearances and distances through solid insulation through
  • 21 Heat, fire and tracking-resistant
  • Corrosion 22
  • 23 Electromagnetic compatibility (EMC) emission requirements ---
  • 24 Assembly
  • 25 Normal operation
  • 26 Electromagnetic compatibility (EMC) requirements --- Immunity
  • 27 Non-normal operation
  • 28 Guidelines for the use of electronic disconnection
  • Figure
  • Appendix
  • Requirements Annex H (normative) electronic controller

Foreword

All technical content in this section is mandatory.

GB 14536 "Household and similar electrical automatic controller" is divided into two parts.

--- Part 1. General requirements;

--- Part 2. Particular requirements.

Special requirements and consists of the following components.

--- GB 14536.3 - Particular requirements for thermal motor protectors (IEC 60730-2-2, IDT);

--- Particular requirements GB 14536.4 tubular fluorescent lamp ballasts for thermal protectors (IEC 60730-2-3, IDT);

--- GB 14536.5 sealed and semi-hermetic motor - compressor motor thermal protection Particular requirements (IEC 60730-2-4, IDT);

--- Particular requirements GB 14536.6 automatic electrical burner control systems (IEC 60730-2-5, IDT);

--- GB 14536.7 pressure sensitive electrical controls - Particular requirements (idt IEC 60730-2-6);

--- GB 14536.8 Particular requirements for timers and time switches (idt IEC 60730-2-7);

--- GB 14536.9 Particular requirements for electrically operated water valves (including mechanical requirements) (IEC 60730-2-8, IDT);

--- GB 14536.10 - Particular requirements for temperature sensing controls (IEC 60730-2-9, IDT);

--- GB 14536.11 Particular requirements for motor starting relays (IEC 60730-2-10, IDT) used;

--- GB 14536.12 Particular requirements for energy regulators (idt IEC 60730-2-11);

--- GB 14536.13 Particular requirements for electrically operated door locks (IEC 60730-2-12, IDT);

--- GB 14536.15 Particular requirements for humidity sensing controls (IEC 60730-2-13, IDT);

--- GB 14536.16 Particular requirements for electric actuators (idt IEC 60730-2-14);

--- GB 14536.17 special requirements of the float or electrode-sensitive automatic electrical water level sensing controller used in the boiler appliance (IEC 60730-2-15, IDT);

--- GB 14536.18 - Particular requirements for household and similar use of the float type level controllers (IEC 60730-2-16, IDT);

--- GB 14536.19 Particular requirements for electrically operated gas valves, including mechanical requirements (IEC 60730-2-17, IDT);

--- GB 14536.20 Particular requirements for water and air flow sensing controls, including mechanical requirements (IEC 60730-2-18, IDT);

--- GB 14536.21 Particular requirements for electrically operated oil valves, including mechanical requirements (IEC 60730-2-19, IDT);

This section identical with IEC 60730-2-19 "Household and similar electrical controls - Part 2. Particular requirements for electrically operated oil valves and mechanical requirements "(first edition in 1997, a revised 2001, revised in 2007 II).

This part of the structure of the IEC 60730-2-19 same. In this section, there is a corresponding national standard, incorporated by reference to national standards; no National standards, IEC standards are incorporated by reference outlined. Choreography sequences of this Part 2 normative references and IEC 60730-2-19 different.

For ease of use, this section made the following editorial changes.

a) "This standard" be replaced by "this section";

b) use a decimal point instead of a decimal comma ",". ",";

c) increase the national standard foreword;

d) with "GB 14536.1" instead of "Part 1." this part of GB 14536.1-2008 "Household and similar electrical controls - Part 1. General requirements" in conjunction.

Appendix H of this part of the normative appendix.

GB 14536.21-2008/IEC 60730-2-19:1997 this part is proposed by the China Electrical Equipment Industrial Association.

This part of the National Standardization Technical Committee household automatic control (SAC/TC212) centralized.

This section is drafted. Guangzhou CVC Testing Institute, Guangzhou Electric Apparatus Research Institute, Ningbo Economic and Technological Development Zone Haixin Electric Technology Co., Ltd.

Drafters of this section. bamboo Li Ping, Liang Heming, Huangkai Yun, Zheng Guoping.

GB 14536.21-2008/IEC 60730-2-19:1997 IEC Foreword

1) IEC (International Electrotechnical Commission) is a worldwide standardization group composed of national electrotechnical committees (IEC National Committees) Organizations. The object of IEC is to promote international cooperation on issues related to the standardization of the electrical and electronic fields. For this purpose IEC addition to other activities, but also publishes International Standards, technical specifications, technical reports, public specification (PAS, Publicly AvailableSpecifications) and guidelines (henceforth referred to IEC publication). Their preparation is entrusted to technical Commission to complete. As a member of IEC National Committees, as long as the interest of the standard to be developed, may participate its formulation. Liaising with the IEC 's international, official or unofficial organizations are also involved in the development of standards.

IEC and the World Organization for Standardization (ISO ) in accordance with the conditions specified in the agreement, close cooperation.

2) since each technical committee has representatives from the National Commission on the relevant issues of interest, so the IEC on technical Issue formal decisions or agreements on the maximum expression of the international consensus on the relevant issues.

3) IEC Publications have the form of recommendations for international use, and accepted by the National Committees in that sense. Despite being made There are possible effort to ensure that the technical content of IEC publications is correct, IEC these publications can not be used Way or misinterpretation of any user and responsibility.

4) In order to promote international unification, IEC National Committees in charge of the IEC international standards transparently converted to the maximum extent possible National or regional standards. Between the IEC Standard and the corresponding national or regional standard if there is any difference, it should be converted into the standard After clearly illustrates.

5) IEC did not develop any signs of approval procedure, when a device if it complies with the IEC declared a publication, which is not IEC Accountable.

6) All users should make sure you have the latest version of this publication.

7) IEC or its leaders, employees, servants or agents, including independent experts and IEC technical committees, national committee Members will, for the use of any person or the trust of the IEC standards or other IEC publication caused casualties, property damage Loss or other damage to the natural environment (whether such losses are direct or indirect) does not bear any responsibility for the phase should produce costs and expenses (including legal fees) is not liable.

8) To take note of the standard referenced standards. Use the referenced standard is correct application of this standard essential.

9) It is noteworthy that this International Standard may involve some parts of the patent. IEC for the identification of some or all of this A Class of the patent will be irresponsible.

International Standard IEC 60730-2-19 by the IEC/T C72. home automation controller Technical Committee.

IEC 60730-2-19 based on its first edition (1997) [documents 72/350/FDIS and 72/373/RVD] and Rev. 1 (2000) [documents 72/467/FDIS and 72/491/RVD] and Rev. 2 (2007) [documents 72/745/FDIS and 72/750 /RVD].

The version number is 1.2.

Vertical edge of the page indicates that the foundation has been revised edition Amendment 1 and Amendment 2 pieces.

Part 2 of this article should be used in conjunction with IEC 60730-1. It is based on the third edition of IEC 60730-1 (1999) and its Amendment 1 member (2003) formed the basis. IEC 607 30-1 should be considered in future editions or revised pieces.

The first part 2 supplements or modifies the corresponding provisions of IEC 60730-1, to make it into the IEC standard. Safety requirements for electrically operated oil valves (Including mechanical requirements).

Part 2, where marked "increase", "modification" or "replacement" of the place, the corresponding requirements, test specifications in Part 1, or comment it should be amended accordingly.

The publication comply with ISO/IEC Directives. Part III.

GB 14536.21-2008/IEC 60730-2-19:1997 where the need to modify the Department, Part 2 will be indicated in the corresponding provisions of Part l of this chapter apply.

The development of international standards, each country must be considered in all regions due to the different requirements of the actual situation formed, and each country should be recognized Electrical systems and wiring codes family differences.

In Part 2 of this article, note the differences in different countries in order to give "in some countries" form; see these differences.

--- Table 7.2, Section 120 requirements;

--- Table 7.2, note 102;

--- 11.103;

--- 11.105.1;

--- 11.105.2;

--- 11.113;

--- 18.102;

--- H. 27.2.101.1;

--- H. 26.10.

In this publication.

1) using the following printing fonts.

--- Requirements Body. roman;

--- Test specifications. italic;

--- Note. The small Roman font.

2) an increase in the base portion of the first strip those, notes, projects and numbered starting from 101.

The Committee decided that the contents of this publication in the IEC website http. // webstore. iec. And specific publications related to the next marked on ch Remain unchanged before the revision date. And to this date, the publication will be.

- reconfirmed;

- Cancel;

- The revised version was replaced; or - Amendment.

GB 14536.21-2008/IEC 60730-2-19:1997 Household and similar electrical automatic controller Particular requirements for electrically operated oil valves, including mechanical requirements

1 Scope and normative references

GB 14536.1 of the chapter, replaced by the following.

instead.

1.1 section applies to household and similar devices or electrically operated oil valves used in conjunction with these devices, these devices can use Electricity, gas, oil, solid fuels, such as solar energy or a combination of applications including heating, air conditioning and similar applications.

This section also applies to NTC or PTC thermistor electric valve, which requirements are contained in Appendix J.

1.1.1 This section applies to electrically operated oil valves inherent security for the protection of equipment related to the operating values and operating procedures applicable to home Use and similar equipment or testing with these devices for use with electrical automatic controller. Also suitable for industrial use, there is no corresponding Standards, such as central heating, air conditioning, electric heat treatment used oil valve.

This section also applies to GB 4706.1 involved in various kinds of electric appliances used oil valve.

This section contains the mechanical properties of the oil valve and the valve's electrical performance requirements, both of which will affect the expected operation of the fuel valve.

Note. In this section, the term "device" includes "instrument and control systems." this section does not apply to electric valve oil specifically for industrial equipment.

For non-household equipment generally electrically operated oil valves, and these devices by non-professionals, such as a store or factory or farm use light Also included within the scope of this.

This section describes some of the mechanical characteristics in the "under consideration." Until the mechanical requirements contained in this section, for each country to use this section

NOTE. electrically operated oil valves meet the requirements of this section does not indicate that these mechanical features do not require further testing.

1.1.2 This section applies to those manual control when its electrical or mechanical constituting the electric valve.

Note. do not belong to a part of the electrically operated oil valves manually switch requirements are contained in the GB 15092.1.

This section does not apply to the nominal size DN150 connection over electric valve.

The term "valve" means electrically operated oil valves (including the original actuator and valve assembly).

1.1.3 together with the electric valve to the test laboratory to assess the electric starter in this section. Independent electric starter in GB 14536.16 the assessment of the criteria for the special requirements for electric actuators.

No electrical output 1.1.4 This section applies to a single valve, grouped together as a system of valves and components with the multi-function controller mechanically Valve.

1.5 Normative References

The following documents contain provisions which, through reference in this Part of GB 14536, constitute provisions of this part. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.

increase.

GB 4208 housing protection (IP Code) (GB 4208-2008, IEC 60529:2001, IDT) Particular requirements for household and similar purposes GB 14536.16 Automatic electrical controls for electric actuators (idtGB 14536.16-2000, IEC 60730-2-14:1995) GB/T 17626.2-2006 Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity test (IEC 61000-4-2:2001, IDT) GB 14536.21-2008/IEC 60730-2-19:1997 ISO 7-1:1994 (all parts) 55 ° sealing pipe thread ISO 228-1:1994 55 ° non-sealing pipe thread ISO 274. 1975 discoid-sectional dimension of copper cable ISO 301. 1981 casting zinc alloy ingots Three-prong electrical plug characteristics and requirements of the 1994 fluid power systems and components with ground contact. ISO 4400 ISO 6952:1994 Fluid power systems and components with electrical plug earth contact feet Characteristics and requirements ISO 7005-1:1992 projecting face with a steel pipe flanges with neck ISO 7005-2. 1988 metal flanges - Part 2. Cast iron pipe flanges

2 Definitions

GB 14536.1 of the chapter is applicable except as follows.

2.2 is defined by use classification controller 2.2.17.101 by the original electric mechanism to implement the transfer, which is operable to control the flow of oil in an automatic valve.

NOTE. Artificial open automatically shut down or automatically turn on manual semi-automatic closing valves also fall into this category definitions.

2.2.17.102

A portion of the valve assembly, is to limit the pressure of the main components. It provides end fittings and oil flow passage together.

2.2.17.103

Used to form the body structure sealed connection with the liquid conduction system.

2.2.17.104

One size digital representation of this size for liquid conduction system, in addition to using the peripheral diameter or thread size representation of member all parts are common.

Note 1. This size can be made after the DN with a suitable number has been rounded to indicate that this number is used for reference purposes only.

Note 2. Some older international standard nominal size is an indicator of nominal diameter, for the purposes of this section, the two terms are synonymous.

2.3 Function controller and related definitions

increase.

2.3.101

On or off, without any intermediate state of the valve.

2.3.102

In the non-energized valve is closed.

2.3.103

In the non-energized valve is open.

2.3.103.1

When the power is closed, the valve does not open automatically when the power is removed, you must manually reset.

GB 14536.21-2008/IEC 60730-2-19:1997 2.3.103.2 when no power is turned on, when the power is removed the valve opens automatically.

2.3.104

Within a predetermined range of flow rates can adjust the flow rate of the valve.

2.3.104.1

Allowing the valve at rated flow rate or at a plurality of predetermined nominal flow rate of the flow rate operation.

2.3.105

A movable valve member positioned in the flow path of the oil flow through the valve is used to change the flow rate.

2.3.106

The outlet side of the valve in the closed position when there is no oil flow member is located.

2.3.107

When the position of the closure of a predetermined oil flow through the outlet valve of the time.

2.3.107.1

Oil flows through the flow rate of the valve closure position in line with nominal flow rate when.

2.3.108

The amount of oil flowing through the valve in unit time.

2.3.109

Flow rate at a given pressure differential specified standard reference conditions of temperature and pressure and viscosity.

2.3.110

Entrance valve pressure.

2.3.111

Pressure at the outlet valve.

2.3.112

The pressure differential between the inlet and the outlet.

2.3.113

The maximum pressure starting declaration allows the closure operation to be overcome poor.

2.3.114

Minimum pressure valve is opened or closed when the statement of difference.

GB 14536.21-2008/IEC 60730-2-19:1997 2.3.115 Valve can start, declared maximum inlet pressure.

Note. You can represented by the letters PN (also refers to the pressure) has a convenient integer, for reference only.

2.3.116

By limiting thermostat, thermal cut or combustion control system to prevent operation of the oil delivered normally closed valve.

Note 1. The safety shut-off valve is considered to protect the controller can also operate as a controller.

Note 2. The safety shut-off valve may be a type of semi-automatic action or actions.

2.3.117

Leaking from the valve body to the atmosphere.

2.3.118

The closing member is in the closed position, the oil leaked from the connecting port outer pipe.

2.3.119

Open the valve to an electrical signal to the time of the maximum flow rate or other defined interval between implementations.

2.3.120

Electrical signal reaches the closed position and the removal of the time interval.

2.3.121

And the valve open period begin to flow between the two electric signals.

2.3.122

As interlock means for monitoring the closed position of the valve closure of an electrical switch.

2.3.123

One kind of the start of the starter valve electrical switch as an electrical output.

2.3.124

Used to implement the valve opening and closing operation of the institution or the original electric actuator.

3 General requirements

GB 14536.1 in this chapter shall apply.

4 General Description, Test

GB 14536.1 in this chapter apply except as follows.

4.1 Test Conditions

4.1.7 Not applicable.

4.3 Test Description

GB 14536.21-2008/IEC 60730-2-19:1997 instead.

4.3.2.6 For the marked or specified rating, more than one set of controllers, test Chapter 17 tests at maximum rated voltage.

increase.

4.3.101 For specified by the manufacturer 6.103 in those same valve body is equipped with different connector size, the maximum 18.101 the joint test.

5 RATINGS

This is applicable in GB 14536.1.

Category 6

GB 14536.1 in this chapter apply except as follows.

6.3 By Application

6.3.12 Addition.

6.3.12.101 on - off valve.

6.3.12.102 normally closed valve.

6.3.12.103 normally open valve.

6.3.12.103.1 normally open valve, automatic.

6.3.12.103.2 normally open valve, semi-automatic locking.

6.3.12.104 valve.

6.3.12.105 multistage valve.

6.3.12.106 safety shut-off valve, automatic.

6.3.12.107 safety shut-off valve, semi-automatic.

6.7 by means breaking the limits of ambient temperature classification modify.

With "valve" instead of "controller", with the "original mechanism" instead of "breaking device." 6.12 instead of.

Press the oil flow through the valve of the liquid temperature classification.

6.15 Classification by structure

increase.

Type classification 6.15.101 press oil example.

No. 1, No. 2, No. 3, No. 4, No. 5 or No. 6 fuel oil 6.15.102 by viscosity, SSU viscosity oil (second Saybolt Universal Viscosity) increase.

6.101 Type classification according to the termination

6.101.1 equipped with a threaded end of the valve within the threaded joint of one of the following.

--- Thread sealing pipe thread connection with ISO 7-1 or NPT (American National Standard taper pipe thread); or

--- Not on the thread sealing thread, through an additional cover gaskets with ISO 228-1 threads.

6.101.2 equipped with a valve threaded end of the outer thread of one of the following joints.

a) Compression fittings; or

b) Washer tube connection; or GB 14536.21-2008/IEC 60730-2-19:1997

c) cone seat tube joints; or

d) ISO 7-1, ISO 228-1 or NPT (American National Standard taper pipe thread) threaded fittings.

Suitable for connection with or without flange adapter flange end of the connector-equipped 6.101.3 valve.

6.101.4 head with valve for soldering or welding joints of the termination.

6.102 According to characteristics of an electric valve classification

6.102.1 Classified according to nominal flow rate

By the size of the inlet and outlet connection sizes and nominal flow rate requirements.

6.102.2 by Function

The number of functions by a pipe joint and non-energized position of the valve classification.

Type 6.102.3 original mechanism of classification example.

--- Solenoid.;

--- Motor;

--- Electric. Electric heating wax bimetal;

--- Electric hydraulic pump;

--- Original auxiliary operation mechanism.

6.102.4 sequence of operations by Category.

Multi-stage valve.

6.103 by end fittings nominal pipe size category.

Thread Size Nominal Size 1/8 DN6 1/4 DN8 3/8 DN10 1/2 DN15 3/4 DN20

1 DN25

11/4 DN32

11/2 DN40

2 DN50

21/2 DN65

3 DN80

4 DN100

5 DN125

6 DN150

Note. According to ISO 7005-1 or ISO 7005-2 in nominal flange size named nominal size.

7 Information

GB 14536.1 in this chapter, except for the following apply.

GB 14536.21-2008/IEC 60730-2-19:1997

Table 7.2

Information chapter, strip method modify.

Replaced with the following corresponding to the following.

Type 7 each circuit controlled by a load of 7) 6.2,14,17 D 15 shell protection grade 8) 6.5.1,6.5.2,11.5,11.102 C 22 points off temperature limit means if Tmin lower than 0 °C, or Tmax not 55 °C 6.7,14.5,14.7,17.3 D

23 Not applicable

26 the number of cycles per start manual operation (M) 101) 6.10 X

28 Not applicable

29 type (for valves with switching device) is disconnected or cut off each circuit to provide 6.9 X 31 allows the mounting position 5) 11.6 D

36 Not applicable

37 Not applicable

38 Not applicable

Type 391 or Type 2 operation (with respect to the valve switching means) 102) 6.4 D Additional features Type 401 or Type 2 action (for valves with switching devices) 6.4.3 D 41 corresponding to these manufacturing variations and deviations of experimental conditions (with respect to the valve switching means) 11.4.3,15,17.14 X 42 drift (for valves with switching devices) 11.4.3,15,16.2.4,17.14 X

43 Not applicable

44 Not applicable

47 Not applicable

48 Operating values or operating time (for valves with switching devices) 15 D

increase.

Power 101 VA with W or loss or rated current represents C 102 with a maximum operating pressure...

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.

Referenced standards

How to Download GB 14536.21-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
17 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 14536.21-2008

$305.00