DL/T 986-2016Technical specification for performance test of wet flue gas desulphurization (English PDF)
湿法烟气脱硫工艺性能检测技术规范
This is a limited preview
Buy now to download the full PDF (31 pages)
Need quotation for your management?
Get a formal quotation for DL/T 986-2016 in 30 minutes.
Issued by
NEA
Level / Type
Industry · Recommended
Issue date
January 7, 2016
Implementation date
June 1, 2016
Scope
DL/T 986-2016 is the English-translated version of 湿法烟气脱硫工艺性能检测技术规范.
DL/T 986-2016 sets out what to measure and how when testing the performance of a wet flue gas desulphurization (FGD) process: the conditions the unit must meet before testing, the test items and methods (flue gas composition and flow, dust, absorbent quality, mist eliminator outlet droplets, gypsum by-product, wastewater, energy consumption, noise and surface temperature), data processing and the test report. It is written for limestone-gypsum wet FGD, and other wet or similar desulphurization processes may be tested with reference to it. Informative annexes give basic parameters, a method for determining SO3 in flue gas and the calculation formulae for efficiency and emission concentrations. It replaces DL/T 986-2005.
Found what you need?
Document preview — DL/T 986-2016
National Standard of the People's Republic of China
- ICS
- 27.100
- Classification
- F 23
- Replacing
- DL/T 986-2005
Issued by: National Energy Administration
Contents
- Foreword2
- 1 Scope3
- 2 Normative references3
- 3 Terms and definitions3
- 4 Test conditions4
- 5 Testing of performance indicators5
- 6 Data processing14
- 7 Test report14
- Annex A (informative) Basic parameters15
- Annex B (informative) Method for the determination of SO3 in flue gas25
- Annex C (informative) Basic formulae29
Foreword
This standard has been drafted in accordance with the rules given in GB/T 1.1-2009 "Directives for standardization - Part 1: Structure and drafting of standards".
This standard is a revision of DL/T 986-2005 "Technical code for performance test of wet flue gas desulfurization process". Compared with DL/T 986-2005, the main modifications in this revision are as follows:
—— clauses on test conditions have been added;
—— the specific indicators in the test content part have been updated;
—— the clauses on functional indicators have been deleted;
—— the relevant clauses on flue gas composition testing have been updated;
—— the clauses on the oxidation test of circulating desulfurization slurry have been deleted;
—— clauses on the testing of flue gas mist droplets at the mist eliminator outlet have been added;
—— the clauses on energy consumption testing have been updated;
—— the relevant clauses on noise testing have been added;
—— the clauses on the environmental condition evaluation system have been deleted;
—— the clauses on the evaluation of test results have been deleted;
—— the clauses on the testing organization have been deleted;
—— the informative annexes on the testing system, the testing organization and the testing procedure have been deleted.
This standard was proposed by the China Electricity Council.
This standard is under the jurisdiction of the Standardization Technical Committee on Environmental Protection of the Electric Power Industry.
Drafting organizations of this standard: Guodian Environmental Protection Research Institute, Datang Technology Industry Group Co., Ltd., Zheneng Technology Research Institute Co., Ltd.
Chief drafters of this standard: Wang Xiaoming, Xue Jianming, Liu Tao, Chen Yan, Wang Hongliang, Li Zhonghua, Liu Chunhong, Ma Lijun, Guan Yiming, Xu Xuesong, Pei Jie, Xue Yangqi, Dong Yuehong.
This standard supersedes DL/T 986-2005 from the date of its implementation.
Comments or suggestions arising during the implementation of this standard should be fed back to the Standardization Management Center of the China Electricity Council (No. 1, Baiguang Road Ertiao, Beijing, 100761).
1 Scope
This standard specifies the content, procedures and methods for performance testing of wet flue gas desulfurization processes.
This standard is applicable to the performance testing of limestone-gypsum wet flue gas desulfurization processes; other wet flue gas desulfurization processes and other similar desulfurization processes may also be carried out with reference to this standard.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only the edition cited applies to this document. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 5484 Methods for chemical analysis of gypsum · GB/T 5762 Methods for chemical analysis of limestone, quicklime and hydrated lime for building materials · GB/T 6904 Determination of pH in industrial circulating cooling water and boiler water · GB/T 7484 Water quality—Determination of fluoride—Ion selective electrode method · GB 8978 Integrated wastewater discharge standard · GB/T 14415 Determination of solid matter in industrial circulating cooling water and boiler water · GB/T 15453 Determination of chloride ion in industrial circulating cooling water and boiler water · GB/T 16157 The determination of particulates and sampling methods of gaseous pollutants emitted from exhaust gas of stationary source · GB 50122 Code for measurement of noise in industrial enterprises · DL/T 323 Method for determination of the activity of quicklime used in dry flue gas desulfurization · DL/T 943 Determination of the reaction rate of limestone powder used in wet flue gas desulfurization · DL/T 997 Water quality control indices for limestone-gypsum wet desulfurization wastewater of thermal power plants · JC/T 478.2 Test methods of building lime · JC/T 2074 Flue gas desulfurization gypsum
3 Terms and definitions
The following terms and definitions apply to this standard.
3.1 desulfurization efficiency
The ratio of the quantity of SO2 removed by the flue gas desulfurization facility per unit time to the quantity of SO2 in the flue gas entering the desulfurization facility.
3.2 sulfur dioxide effluent-quality concentration
After SO2 has been removed from the flue gas by the desulfurization facility, the actually measured volumetric discharge concentration of SO2 converted into the mass concentration of SO2 under the standard state of dry flue gas (101.3 kPa, 273.15 K, zero humidity) and at an oxygen content of 6%.
3.3 calcium-sulfur stoichiometric proportion
The ratio of the number of moles of calcium-based absorbent fed into the desulfurization facility to the number of moles of SO2 removed by the desulfurization facility; it also indicates the degree of excess of desulfurization absorbent required for the desulfurization facility to attain a given desulfurization efficiency.
3.4 liquid-gas ratio
The ratio of the volumetric flow rate of the slurry sprayed in the absorber to the volumetric flow rate of the wet flue gas at the absorber outlet under standard conditions.
3.5 oxidation rate of the desulfurated accessory substances
The degree to which calcium sulfite in the solid material of the desulfurization by-product is oxidized into calcium sulfate, which refers to the ratio of the number of moles of sulfate ions in the solid material of the desulfurization by-product to the sum of the numbers of moles of sulfate ions and sulfite ions.
3.6 moisture content of the desulfurated accessory substances
The mass fraction of water in the solid material of the desulfurization by-product, excluding the water of crystallization in the solid material.
3.7 dripping content of the demister outlet gas
The mass concentration of the slurry carried in the flue gas at the demister outlet.
3.8 limestone dissolution rate
The reaction rate between the carbonate in limestone and acid.
Remaining clauses in the full document
- 4 Test conditions
- 5 Testing of performance indicators
- 5.1 Test items
- 5.2 Test methods
- 5.3 Test conclusions
- 6 Data processing
- 7 Test report
- Annex A (informative) Basic parameters
- Annex B (informative) Method for the determination of SO3 in flue gas
- Annex C (informative) Basic formulae
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 31 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 5484Methods for chemical analysis of gypsum
- GB/T 5762Methods for chemical analysis of limestone, quicklime and hydrated lime for building materials industry
- GB/T 6904Determination of pH in water for industrial recirculating cooling systems and boilers
- GB/T 7484Water quality--Determination of fluoride--Ion selective electrode method
- GB/T 14415Water for industrial circulating cooling system and boiler - Determination of solids matter
- GB/T 15453Determination of chloride in water for industrial circulating cooling system and boiler
GB 8978 · GB 50122 · DL/T 323 · DL/T 943 · DL/T 997 · JC/T 478.2 · JC/T 2074
Similar standards
DL/T 943|DL/T 997|GB/T 16157|JC/T 2074
Editions of DL/T 986
| Edition | Title | Revision | Status |
|---|---|---|---|
| DL/T 986-2016 | Technical specification for performance test of wet flue gas desulphurization | first revision | Current |
| DL/T 986-2005 | Technical code for performance test of wet flue gas desulfurization process | first issue | Superseded |
This page sells the current edition, DL/T 986-2016. Earlier editions are listed for reference only.
How to Download DL/T 986-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 14415-2007 — Water for industrial circulating cooling system and boiler - Determination of solids matter
GB/T 15453-2018 — Determination of chloride in water for industrial circulating cooling system and boiler
GB/T 16157-1996 — Determination of particulates and sampling methods of gaseous pollutants emitted from exhaust gas of stationary source
Secure payment via Stripe
Payments accepted
DL/T 986-2016
$260.00