CJ/T 224-2012Electronic remote-reading water meter (English PDF)
电子远传水表
This is a limited preview
Buy now to download the full PDF (30 pages)
Need quotation for your management?
Get a formal quotation for CJ/T 224-2012 in 30 minutes.
Issued by
Ministry of Housing and Urban-Rural Development of the People's Republic of China
Level / Type
National · Recommended
Issue date
February 6, 2012
Implementation date
August 1, 2012
Scope
CJ/T 224-2012 is the English-translated version of 电子远传水表.
CJ/T 224-2012 — This standard stipulates the electronic remote-reading water-meter's terms and definitions, structure and classification, metrological requirements, technical requirements, test method, inspection rules and mark, packaging, transportation, and storage.
This standard is applicable to water-meters that have digital output signal and comply with relevant provisions of GB/T 778.1-2007 and GB/T 778.3-2007.
Found what you need?
Document preview — CJ/T 224-2012
National Standard of the People's Republic of China
- ICS
- 91.140.60
Contents
- Foreword1
- Scope2
- Normative references3
- Terms and Definitions4
- Appearance5
- Electronic seal6
- Material and structure of the electronic remote-reading water-meter7
- Adjustment of the electronic remote-reading water-meter8
- Verification marks and protective devices9
- Inspection device10
- Indication device11
- Diameter and overall dimensions of the electronic remote-reading12
- Reliability of electronic devices13
- Enclosure protection14
- Test requirements15
Foreword
This standard is drafted according to the rules specified in GB/T 1.1-2009.
This standard is the revision to CJ/T 224-2006 Electronic Remote-reading Water-meter.
Compared with CJ/T 224-2006, the main technical changes of this standard are as follows.
— Add the terms and definitions of mechanical-electric conversion, mechanical-electric conversion devices. Deleted the terms and definitions of the devices to be tested;
— Add the classification by indication device;
— Change the measurement characteristics into metrological requirements. Add zero-flow integrating reading, rated operation conditions, sensitive class of sectional flow, and other 4 requirements;
— Change the appearance seal to visual inspection requirements. Add 6 items' requirements - electronic seal, material and structure requirements of electronic remote-reading water-meter, adjustment of electronic remote-reading water-meter, verification marks and protective device, inspection device, and indication device.
— Delete requirements of "other outline dimensions shall be provided by the manufacturing plant on its own" in technical characteristics. Add requirements of flange connection end of electronic remote-reading water-meter;
— Modify the requirements of electronic device properties;
— Modify the requirements of climatic environment, electromagnetic environment and power supply;
— Change the mean time between failures (MTBF) of controller of electronic remote-reading water-meter to be not less than 2.63X104h;
— Supplement that the error test of mechanical-electric conversion is only applicable to the mechanical electronic remote-reading water-meter. Type inspection shall be performed after the completion of test of 7 items that are stipulated in 7.8.1, 7.8.2, 7.8.3, 7.9.3, 7.10.3, 7.11.1 and 7.11.2;
— Modify the test methods of climatic environment, electromagnetic environment and power supply;
— Add the informative annex.
This standard was proposed by Standard Rating Institute of Ministry of Housing and Urban-rural Development.
Electronic remote-reading water meter
1 Scope
This standard stipulates the electronic remote-reading water-meter's terms and definitions, structure and classification, metrological requirements, technical requirements, test method, inspection rules and mark, packaging, transportation, and storage.
This standard is applicable to water-meters that have digital output signal and comply with relevant provisions of GB/T 778.1-2007 and GB/T 778.3-2007.
2 Normative references
The articles contained in the following documents have become part of this document when they are quoted herein. For the dated documents so quoted, all the modifications (including all corrections) or revisions made thereafter shall be applicable to this document.
GB/T 191 Packaging - Pictorial marking for handling of goods GB/T 778.1-2007 Measurement of water flow in fully charged closed conduits -Meters for cold potable water and hot water - Part 1. Specifications (ISO 4064-1:2005, IDT) GB/T 778.3-2007 Measurement of water flow in fully charged closed conduits -Meters for cold potable water and hot water - Part 3. Test methods and equipment (ISO 4064-3:2005 IDT) GB/T 2423.8 Environmental testing for electric and electronic products Part 2. Test methods Test Ed. Free fall (idt IEC 68-2-32:1990) GB 4208-2008 Degrees of protection provided by enclosure (IP code) (IDT IEC 60529:2001) GB/T 5080.7-1986 Equipment reliability testing - Compliance test plans for failure rate and mean time between failures assuming constant failure rate (idt IEC 605-7-1978) GB/T 15464 General-purpose specification for the packaging of instrumentation products GB/T 15479-1995 Technical requirements and test methods of insulation resistance and insulating strength for use in industrial process measurement and control instruments JB/T 9329 Basic environmental conditions and testing methods for instruments transportation and storage in the transportation
3 Terms and Definitions
For the purpose of this document, terms and definitions defined in GB/T 778.1 AND the following terms and definitions apply.
Electronic remote-reading water-meter the water-meter that has digital output signal; the function of water flow signal acquisition;
and functions such as data processing, storage, and remote transmission.
Mother meter
The velocity-type water-meter and volumetric water-meter that are used to measure water.
Electronic device
A part of the electronic remote-reading water-meter. It adopts electronic components to execute the specific functions such as water flow's signal conversion, data processing and information storage, and signal remote transmission. The electronic device can be made to be independent; it can be tested independently.
Mechanical-electric conversion the process that the mechanical counting signal of accumulative volume of the electronic remote-reading water-meter is converted into electronic counting signal.
Mechanical-electric conversion device the electronic components that perform mechanical-electric conversion.
6.1.1 Appearance
The electronic remote-reading water-meter shall have good finishing, no burr, scratch, crack, corrosion, mildew stain and coating peeling.
The displayed digits shall be eye-catching, clean. The text symbols and marks indicating the function shall be complete, clear and correct.
Protective glass on the reading device shall be in good transparency. There shall not have defects such as making the reading distorted.
6.1.2 Electronic seal
Electronic seal of the electronic remote-reading water-meter shall comply with the provisions of 6.5 in GB/T 778.1-2007.
6.1.3 Material and structure of the electronic remote-reading water-meter
Material and structure of the electronic remote-reading water-meter shall comply with the provisions of 6.1 in GB/T 778.1-2007.
6.1.4 Adjustment of the electronic remote-reading water-meter
Adjustment of the electronic remote-reading water-meter shall comply with the provisions of 6.3 in GB/T 778.1-2007.
6.1.5 Verification marks and protective devices
Verification marks and protective devices of the electronic remote-reading water-meter shall comply with the provisions of 6.4 in GB/T 778.1-2007.
6.1.6 Inspection device
Inspection device of the electronic remote-reading water-meter shall comply with the provisions of 6.7.2 in GB/T 778.1-2007.
6.1.7 Indication device
The indication device of electronic remote-reading water-meter shall comply with the provisions of 6.6 and 6.7.3 in GB/T 778.1-2007.
6.2.1 Diameter and overall dimensions of the electronic remote-reading
water-meter
Diameter and overall dimensions of the electronic remote-reading water-meter shall comply with the provisions of 4.1.1 in GB/T 778.1-2007.
Durability of the electronic remote-reading water-meter shall comply with the provisions of 6.2 in GB/T 778.1-2007.
6.11 Reliability of electronic devices
Under specified application conditions, MTBF of electronic device of the electronic remote-reading water-meter shall not be less than 2.63X104h.
6.12 Enclosure protection
The electronic device of the electronic remote-reading water-meter, the leading-out wires and the sealing device of leading-out wires shall reach the IP65's protective level as specified in GB 4208-2008. For the special application that requires to operate and submerge in the water, the protective level shall reach IP68's protective level.
7.1 Test requirements
Requirements for general tests shall comply with provisions of Chapter 4, GB/T 778.3-2007. At the same time, it shall be equipped with the handheld unit, portable or stationary meter reading system that are matched for data transmission of the electronic remote-reading water-meter. Check the functions prior to test. It can only be put...
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 30 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 191Graphical symbols marking for handling and storage of packages
- GB/T 778.1-2007Meters for cold potable water and hot water -- Part 1: Metrological requirements and technical requirements
- GB/T 778.3-2007Meters for cold potable water and hot water -- Part 3: Test report format
- GB/T 2423.8Environmental testing for electric and electronic products - Part 2: Test methods - Test Ed: Free fall
- GB/T 5080.7-1986Equipment reliability testing. Compliance test plans for failure rate and mean time between failures assuming constant failure rate
- GB/T 15479-1995Technical requirements and test methods of insulation resistance and insulating strength for use in industrial process measurement and control instruments
ISO 4064 · IEC 68 · GB 4208-2008 · IEC 60529 · IEC 605 · GB/T 15464
How to Download CJ/T 224-2012
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 15479-1995 — Technical requirements and test methods of insulation resistance and insulating strength for use in industrial process measurement and control instruments
GB/T 191-2025 — Graphical symbols marking for handling and storage of packages
GB/T 1910-2015 — Newsprint
Secure payment via Stripe
Payments accepted
CJ/T 224-2012