YY/T 1987-2025Brain-computer interface medical device - Vocabulary (English PDF)

采用脑机接口技术的医疗器械 术语

Preview PDF

This is a limited preview

Buy now to download the full PDF (30 pages)

Need quotation for your management?

Get a formal quotation for YY/T 1987-2025 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

September 15, 2025

Implementation date

January 1, 2026

Scope

YY/T 1987-2025 is the English-translated version of 采用脑机接口技术的医疗器械 术语.

YY/T 1987 is the vocabulary the whole Chinese brain-computer interface framework is built on. It defines the terms and definitions for medical devices employing brain-computer interface technology, abbreviated in the standards themselves to BCI medical devices.

A terminology standard sounds like the least consequential document in a series until you notice that the test method standards cite it normatively: YY/T 1996, on closed-loop implantable neurostimulators, takes its terms from here, so the two are read together.

It was issued in September 2025 and took effect on 1 January 2026, ahead of the test method standards that depend on it. For any company developing implanted or non-invasive BCI devices for China, this is the document that fixes what the regulator means by each term, and the place where a submission's language has to align.

Found what you need?

Document preview — YY/T 1987-2025

National Standard of the People's Republic of China

ICS
11.040.01
Classification
C30

Issued by: National Medical Products Administration

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 3.1 Basic Concepts
  • 3.2 Technical Terminology

Foreword

This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part

1.Structure and Drafting Rules of Standardization Documents". Drafting. Please note that some content in this document may involve patents. This document is published. The organization is not responsible for identifying patents. This document was proposed by the National Medical Products Administration. This document is under the jurisdiction of the Technical Committee on Standardization of Medical Electrical Appliances (SAC/TC 10). The main drafting units of this document are. Shanghai Institute for Medical Device Testing, Nanhu Brain-Computer Interaction Research Institute, Lingang National Laboratory, and National Pharmaceutical Research Institute. Medical Device Evaluation Center of the State Food and Drug Administration, China National Institutes for Food and Drug Control, Huashan Hospital Affiliated to Fudan University, Capital Medical University Xuanwu Hospital, Beijing Tiantan Hospital affiliated to Capital Medical University, Center for Excellence in Brain Science and Intelligence Technology, Chinese Academy of Sciences, Brain-Computer Interaction and Human... The Haihe Laboratory for Machine-Machine Collaboration, Beijing Institute of Brain Science and Brain-Inspired Intelligence, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, and Tsinghua University. The main drafters of this document are. Hu Sheng, Liu Xun, Yu Hongyi, Wang Yueming, Zhou Sishu, Li Chengyu, Xie Yang, Liang Hong, Jin Ruonan, Li Shu, and Han Qianqian. Mao Ying, Chen Liang, Zhao Guoguang, Shan Yongzhi, Jia Wang, Zhou Wenjianlong, Zhao Zhengtuo, Li Xue, Ming Dong, Xu Minpeng, Luo Minmin, Zhang Lei, Tao Hu, Zhou Zhitao Hongbo. Medical device terminology using brain-computer interface technology

1 Scope

YY/T 1987 is the vocabulary the whole Chinese brain-computer interface framework is built on. It defines the terms and definitions for medical devices employing brain-computer interface technology, abbreviated in the standards themselves to BCI medical devices. A terminology standard sounds like the least consequential document in a series until you notice that the test method standards cite it normatively: YY/T 1996, on closed-loop implantable neurostimulators, takes its terms from here, so the two are read together. It was issued in September 2025 and took effect on 1 January 2026, ahead of the test method standards that depend on it. For any company developing implanted or non-invasive BCI devices for China, this is the document that fixes what the regulator means by each term, and the place where a submission's language has to align.

This document defines the terminology and definitions for medical devices that employ brain-computer interface technology (hereinafter referred to as brain-computer interface medical devices). This document applies to brain-computer interface medical devices.

2 Normative references

This document has no normative references.

3 Terms and Definitions

The following terms and definitions apply to this document.

3.1 Basic Concepts

3.1.1 Brain-computer/machine interface medical devices (BCI-MD/) utilize brain-computer interface technology. BMI-MD By measuring and decoding neural signals generated by the central nervous system in real time through invasive or non-invasive methods, patients can receive external assistance or treatment. Active medical devices are those that achieve clinical effects such as improving, repairing, or replacing the function of the central nervous system through real-time two-way interaction or closed-loop feedback.

Note. Closed-loop feedback is a technique used in the field of neuromodulation. Currently, in the field of brain-computer interface medical devices, this technology is mainly applied to devices with closed-loop feedback. Medical devices such as implantable neurostimulators with specific functions.

3.1.2 Invasive brain-computer interface medical devices. BCI-MD/BMI-MD Brain-computer interface medical devices that record neural activity by piercing the skin or entering the body cavity. Note

1.For an explanation of "brain-computer interface medical devices", see Appendix A. Note

2.Invasive brain-computer interface medical devices typically employ intracranial signal technologies such as iEEG, Spike, ECoG, and sEEG. Note

3.Invasive brain-computer interface medical devices typically include semi-invasive, interventional, and implantable forms.

3.1.3 Non-invasive brain-computer interface medical devices BCI-MD/BMI-MD Brain-computer interface medical devices that record neural activity without piercing the skin or entering body cavities.

3.2 Technical Terminology

3.2.1 event A time marker associated with a specific neural activity or external stimulus.

3.2.2 Event-related potential (ERP) Neurophysiological responses in brain electrical activity that are time-dependent on specific external or internal events.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 30 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download YY/T 1987-2025

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
30 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 1987-2025

$330.00